惯性聚合 高效追踪和阅读你感兴趣的博客、新闻、科技资讯
阅读原文 在惯性聚合中打开

推荐订阅源

J
Java Code Geeks
Last Week in AI
Last Week in AI
T
Tailwind CSS Blog
WordPress大学
WordPress大学
B
Blog RSS Feed
T
The Blog of Author Tim Ferriss
F
Fortinet All Blogs
aimingoo的专栏
aimingoo的专栏
MongoDB | Blog
MongoDB | Blog
博客园 - Franky
C
Check Point Blog
P
Proofpoint News Feed
H
Help Net Security
月光博客
月光博客
博客园_首页
Stack Overflow Blog
Stack Overflow Blog
博客园 - 三生石上(FineUI控件)
Martin Fowler
Martin Fowler
Recent Announcements
Recent Announcements
人人都是产品经理
人人都是产品经理
U
Unit 42
美团技术团队
I
InfoQ
A
About on SuperTechFans

eess.SP updates on arXiv.org

ECG-biometrics-bench: A Unified Framework for Reproducible Benchmarking of ECG Biometrics Physiology-Aware Masked Cross-Modal Reconstruction for Biosignal Representation Learning Towards Improving Speaker Distance Estimation through Generative Impulse Response Augmentation Federated Learning with Hypergradient-based Online Update of Aggregation Weights Soft Graph Diffusion Transformer for MIMO Detection SPLICE: Latent Diffusion over JEPA Embeddings for Conformal Time-Series Inpainting Sequential Inference for Gaussian Processes: A Signal Processing Perspective Statistical Channel Fingerprint Construction for Massive MIMO: A Unified Tensor Learning Framework Recent Advances in mm-Wave and Sub-THz/THz Oscillators for FutureG Technologies Cross-Subject Generalization for EEG Decoding: A Survey of Deep Learning Methods Super-resolution Multi-signal Direction-of-Arrival Estimation by Hankel-structured Sensing and Decomposition Hankel and Toeplitz Rank-1 Decomposition of Arbitrary Matrices with Applications to Signal Direction-of-Arrival Estimation Adaptive Transform Coding for Semantic Compression EdgeSpike: Spiking Neural Networks for Low-Power Autonomous Sensing in Edge IoT Architectures Sparse Graph Learning from Sparse Data via Fiedler Number Maximization A Deep Learning Model for Battery State Prediction towards Intelligent Energy Management Transfer Learning for Tonal Noise Prediction in VRF Units Using Thermodynamic and Vibration Signals EVT-Based Generative AI for Tail-Aware Channel Estimation Monitoring exposure-length variations in submarine power cables using distributed fiber-optic sensing BandRouteNet: An Adaptive Band Routing Neural Network for EEG Artifact Removal Phase-Separated Complex Hilbert PCA on Markerless 3D Pose Estimation Data: A Global Phase Network and Its Extension to a Continuous Field on the Body Surface Selective Correlation Based Knowledge Distillation for Ground Reaction Force Estimation Deep Learning-Enabled Dissolved Oxygen Sensing in Biofouling Environments for Ocean Monitoring Speech Enhancement Based on Drifting Models Robust and Clinically Reliable EEG Biomarkers: A Cross Population Framework for Generalizable Parkinson's Disease Detection An AI-Based Supervisory Measurement Integrity Validation Layer for Cyber-Resilient AC/DC Protection in Inverter-Based Microgrids Explainable AI in Speaker Recognition -- Making Latent Representations Understandable Time-Localized Parametric Decomposition of Respiratory Airflow for Sub-Breath Analysis NAKUL-Med: Spectral-Graph State Space Models with Dynamics Kernels for Medical Signals An Algorithm for On-Sensor Agnostic Detection of Changes in Human Activity for Ultra-Low-Power Applications
Choosing a sampling frequency for ECG QRS detection using...
Ahsan Habib, Chandan Karmakar, John Yearwood · 2020-07-04 · via eess.SP updates on arXiv.org

Automated QRS detection methods depend on the ECG data which is sampled at a certain frequency, irrespective of filter-based traditional methods or convolutional network (CNN) based deep learning methods. These methods require a selection of the sampling frequency at which they operate in the very first place. While working with data from two different datasets, which are sampled at different frequencies, often, data from both the datasets may need to resample at a common target frequency, which may be the frequency of either of the datasets or could be a different one. However, choosing data sampled at a certain frequency may have an impact on the model's generalisation capacity, and complexity. There exist some studies that investigate the effects of ECG sample frequencies on traditional filter-based methods, however, an extensive study of the effect of ECG sample frequency on deep learning-based models (convolutional networks), exploring their generalisability and complexity is yet to be explored. This experimental research investigates the impact of six different sample frequencies (50, 100, 250, 500, 1000, and 2000Hz) on four different convolutional network-based models' generalisability and complexity in order to form a basis to decide on an appropriate sample frequency for the QRS detection task for a particular performance requirement. Intra-database tests report an accuracy improvement no more than approximately 0.6\% from 100Hz to 250Hz and the shorter interquartile range for those two frequencies for all CNN-based models. The findings reveal that convolutional network-based deep learning models are capable of scoring higher levels of detection accuracies on ECG signals sampled at frequencies as low as 100Hz or 250Hz while maintaining lower model complexity (number of trainable parameters and training time).