惯性聚合 高效追踪和阅读你感兴趣的博客、新闻、科技资讯
阅读原文 在惯性聚合中打开

推荐订阅源

aimingoo的专栏
aimingoo的专栏
宝玉的分享
宝玉的分享
博客园 - 【当耐特】
博客园 - 司徒正美
L
LangChain Blog
有赞技术团队
有赞技术团队
大猫的无限游戏
大猫的无限游戏
Stack Overflow Blog
Stack Overflow Blog
Engineering at Meta
Engineering at Meta
U
Unit 42
Microsoft Azure Blog
Microsoft Azure Blog
I
InfoQ
博客园 - 叶小钗
H
Hackread – Cybersecurity News, Data Breaches, AI and More
J
Java Code Geeks
月光博客
月光博客
量子位
让小产品的独立变现更简单 - ezindie.com
让小产品的独立变现更简单 - ezindie.com
博客园_首页
Last Week in AI
Last Week in AI
人人都是产品经理
人人都是产品经理
Google DeepMind News
Google DeepMind News
云风的 BLOG
云风的 BLOG
D
DataBreaches.Net

eess.SP updates on arXiv.org

ECG-biometrics-bench: A Unified Framework for Reproducible Benchmarking of ECG Biometrics Physiology-Aware Masked Cross-Modal Reconstruction for Biosignal Representation Learning Towards Improving Speaker Distance Estimation through Generative Impulse Response Augmentation Federated Learning with Hypergradient-based Online Update of Aggregation Weights Soft Graph Diffusion Transformer for MIMO Detection SPLICE: Latent Diffusion over JEPA Embeddings for Conformal Time-Series Inpainting Sequential Inference for Gaussian Processes: A Signal Processing Perspective Statistical Channel Fingerprint Construction for Massive MIMO: A Unified Tensor Learning Framework Recent Advances in mm-Wave and Sub-THz/THz Oscillators for FutureG Technologies Cross-Subject Generalization for EEG Decoding: A Survey of Deep Learning Methods Super-resolution Multi-signal Direction-of-Arrival Estimation by Hankel-structured Sensing and Decomposition Hankel and Toeplitz Rank-1 Decomposition of Arbitrary Matrices with Applications to Signal Direction-of-Arrival Estimation Adaptive Transform Coding for Semantic Compression EdgeSpike: Spiking Neural Networks for Low-Power Autonomous Sensing in Edge IoT Architectures Sparse Graph Learning from Sparse Data via Fiedler Number Maximization A Deep Learning Model for Battery State Prediction towards Intelligent Energy Management Transfer Learning for Tonal Noise Prediction in VRF Units Using Thermodynamic and Vibration Signals EVT-Based Generative AI for Tail-Aware Channel Estimation Monitoring exposure-length variations in submarine power cables using distributed fiber-optic sensing BandRouteNet: An Adaptive Band Routing Neural Network for EEG Artifact Removal Phase-Separated Complex Hilbert PCA on Markerless 3D Pose Estimation Data: A Global Phase Network and Its Extension to a Continuous Field on the Body Surface Selective Correlation Based Knowledge Distillation for Ground Reaction Force Estimation Deep Learning-Enabled Dissolved Oxygen Sensing in Biofouling Environments for Ocean Monitoring Speech Enhancement Based on Drifting Models Robust and Clinically Reliable EEG Biomarkers: A Cross Population Framework for Generalizable Parkinson's Disease Detection An AI-Based Supervisory Measurement Integrity Validation Layer for Cyber-Resilient AC/DC Protection in Inverter-Based Microgrids Explainable AI in Speaker Recognition -- Making Latent Representations Understandable Time-Localized Parametric Decomposition of Respiratory Airflow for Sub-Breath Analysis NAKUL-Med: Spectral-Graph State Space Models with Dynamics Kernels for Medical Signals An Algorithm for On-Sensor Agnostic Detection of Changes in Human Activity for Ultra-Low-Power Applications
Reliability and Validity of the Polar V800 Sports Watch f...
Manuel-Vicente Garnacho-Castaño, Marcos Faundez-Zanuy, Noemi Ser · 2022-03-28 · via eess.SP updates on arXiv.org

This study aimed to assess the reliability and validity of the Polar V800 to measure vertical jump height. Twenty-two physically active healthy men (age: 22.89 +- 4.23 years; body mass: 70.74 +- 8.04 kg; height: 1.74 +- 0.76 m) were recruited for the study. The reliability was evaluated by comparing measurements acquired by the Polar V800 in two identical testing sessions one week apart. Validity was assessed by comparing measurements simultaneously obtained using a force platform (gold standard), high-speed camera and the Polar V800 during squat jump (SJ) and countermovement jump (CMJ) tests. In the test-retest reliability, high intraclass correlation coefficients (ICCs) were observed (mean: 0.90, SJ and CMJ) in the Polar V800. There was no significant systematic bias +- random errors (p > 0.05) between test-retest. Low coefficients of variation (<5%) were detected in both jumps in the Polar V800. In the validity assessment, similar jump height was detected among devices (p > 0.05). There was almost perfect agreement between the Polar V800 compared to a force platform for the SJ and CMJ tests (Mean ICCs = 0.95; no systematic bias +- random errors in SJ mean: -0.38 +- 2.10 cm, p > 0.05). Mean ICC between the Polar V800 versus high-speed camera was 0.91 for the SJ and CMJ tests, however, a significant systematic bias +- random error (0.97 +- 2.60 cm; p = 0.01) was detected in CMJ test. The Polar V800 offers valid, compared to force platform, and reliable information about vertical jump height performance in physically active healthy young men.