惯性聚合 高效追踪和阅读你感兴趣的博客、新闻、科技资讯
阅读原文 在惯性聚合中打开

推荐订阅源

Blog — PlanetScale
Blog — PlanetScale
Cyber Security Advisories - MS-ISAC
Cyber Security Advisories - MS-ISAC
Vercel News
Vercel News
B
Blog
腾讯CDC
P
Proofpoint News Feed
Google DeepMind News
Google DeepMind News
N
Netflix TechBlog - Medium
L
LangChain Blog
F
Fortinet All Blogs
T
The Blog of Author Tim Ferriss
人人都是产品经理
人人都是产品经理
OSCHINA 社区最新新闻
OSCHINA 社区最新新闻
I
InfoQ
IT之家
IT之家
酷 壳 – CoolShell
酷 壳 – CoolShell
aimingoo的专栏
aimingoo的专栏
D
DataBreaches.Net
Stack Overflow Blog
Stack Overflow Blog
The Cloudflare Blog
Last Week in AI
Last Week in AI
奇客Solidot–传递最新科技情报
奇客Solidot–传递最新科技情报
博客园 - 三生石上(FineUI控件)
T
Tailwind CSS Blog

cs.CV updates on arXiv.org

ClawGUI: A Unified Framework for Training, Evaluating, and Deploying GUI Agents On the Robustness of Watermarking for Autoregressive Image Generation Revisiting Compositionality in Dual-Encoder Vision-Language Models: The Role of Inference Anthropogenic Regional Adaptation in Multimodal Vision-Language Model From Redaction to Restoration: Deep Learning for Medical Image Anonymization and Reconstruction The Salami Slicing Threat: Exploiting Cumulative Risks in LLM Systems BoxTuning: Directly Injecting the Object Box for Multimodal Model Fine-Tuning Semantic-Geometric Dual Compression: Training-Free Visual Token Reduction for Ultra-High-Resolution Remote Sensing Understanding Lightweight Low-Light Image Enhancement via Distribution-Normalizing Preprocessing and Depthwise U-Net Back to the Barn with LLAMAs: Evolving Pretrained LLM Backbones in Finetuning Vision Language Models Pseudo-Unification: Entropy Probing Reveals Divergent Information Patterns in Unified Multimodal Models QShield: Securing Neural Networks Against Adversarial Attacks using Quantum Circuits Evaluating the Impact of Medical Image Reconstruction on Downstream AI Fairness and Performance Retinal Cyst Detection from Optical Coherence Tomography Images LoViF 2026 The First Challenge on Weather Removal in Videos STORM: End-to-End Referring Multi-Object Tracking in Videos Data-Efficient Surgical Phase Segmentation in Small-Incision Cataract Surgery: A Controlled Study of Vision Foundation Models Rethinking the Diffusion Model from a Langevin Perspective Zero-shot World Models Are Developmentally Efficient Learners Edu-MMBias: A Three-Tier Multimodal Benchmark for Auditing Social Bias in Vision-Language Models under Educational Contexts VGA-Bench: A Unified Benchmark and Multi-Model Framework for Video Aesthetics and Generation Quality Evaluation Degradation-Consistent Paired Training for Robust AI-Generated Image Detection FREE-Switch: Frequency-based Dynamic LoRA Switch for Style Transfer Demographic and Linguistic Bias Evaluation in Omnimodal Language Models FlowPalm: Optical Flow Driven Non-Rigid Deformation for Geometrically Diverse Palmprint Generation Cross-Cultural Value Awareness in Large Vision-Language Models I Walk the Line: Examining the Role of Gestalt Continuity in Object Binding for Vision Transformers GLEaN: A Text-to-image Bias Detection Approach for Public Comprehension From UAV Imagery to Agronomic Reasoning: A Multimodal LLM Benchmark for Plant Phenotyping Not Your Stereo-Typical Estimator: Combining Vision and Language for Volume Perception
Patient-specific vs Multi-Patient Vision Transformer for ...
Gauthier Rotsart de Hertaing, Dani Manjah, Benoit Macq · 2025-07-10 · via cs.CV updates on arXiv.org

Background: Accurate forecasting of lung tumor motion is essential for precise dose delivery in proton therapy. While current markerless methods mostly rely on deep learning, transformer-based architectures remain unexplored in this domain, despite their proven performance in trajectory forecasting. Purpose: This work introduces a markerless forecasting approach for lung tumor motion using Vision Transformers (ViT). Two training strategies are evaluated under clinically realistic constraints: a patient-specific (PS) approach that learns individualized motion patterns, and a multi-patient (MP) model designed for generalization. The comparison explicitly accounts for the limited number of images that can be generated between planning and treatment sessions. Methods: Digitally reconstructed radiographs (DRRs) derived from planning 4DCT scans of 31 patients were used to train the MP model; a 32nd patient was held out for evaluation. PS models were trained using only the target patient's planning data. Both models used 16 DRRs per input and predicted tumor motion over a 1-second horizon. Performance was assessed using Average Displacement Error (ADE) and Final Displacement Error (FDE), on both planning (T1) and treatment (T2) data. Results: On T1 data, PS models outperformed MP models across all training set sizes, especially with larger datasets (up to 25,000 DRRs, p < 0.05). However, MP models demonstrated stronger robustness to inter-fractional anatomical variability and achieved comparable performance on T2 data without retraining. Conclusions: This is the first study to apply ViT architectures to markerless tumor motion forecasting. While PS models achieve higher precision, MP models offer robust out-of-the-box performance, well-suited for time-constrained clinical settings.