Abstract:Low-cost air quality sensors (LCS) provide a practical alternative to expensive regulatory-grade instruments, making dense urban monitoring networks possible. Yet their adoption is limited by calibration challenges, including sensor drift, environmental cross-sensitivity, and variability in performance from device to device. This work presents a deep learning framework for calibrating LCS measurements of PM$_{2.5}$, PM$_{10}$, and NO$_2$ using a Long Short-Term Memory (LSTM) network, trained on co-located reference data from the OxAria network in Oxford, UK. Unlike the Random Forest (RF) baseline, which treats each observation independently, the proposed approach captures temporal dependencies and delayed environmental effects through sequence-based learning, achieving higher $R^2$ values across training, validation, and test sets for all three pollutants. A feature set is constructed combining time-lagged parameters, harmonic encodings, and interaction terms to improve generalization on unseen temporal windows. Validation of unseen calibrated values against the Equivalence Spreadsheet Tool 3.1 demonstrates regulatory compliance with expanded uncertainties of 22.11% for NO$_2$, 12.42% for PM$_{10}$, and 9.1% for PM$_{2.5}$.
| Subjects: | Machine Learning (cs.LG) |
| Cite as: | arXiv:2604.21527 [cs.LG] |
| (or arXiv:2604.21527v1 [cs.LG] for this version) | |
| https://doi.org/10.48550/arXiv.2604.21527 arXiv-issued DOI via DataCite (pending registration) |
From: Arindam Sengupta [view email]
[v1]
Thu, 23 Apr 2026 10:51:13 UTC (3,559 KB)
此内容由惯性聚合(RSS阅读器)自动聚合整理,仅供阅读参考。 原文来自 — 版权归原作者所有。