惯性聚合 高效追踪和阅读你感兴趣的博客、新闻、科技资讯
阅读原文 在惯性聚合中打开

推荐订阅源

Security Archives - TechRepublic
Security Archives - TechRepublic
T
The Exploit Database - CXSecurity.com
P
Proofpoint News Feed
Scott Helme
Scott Helme
NISL@THU
NISL@THU
Cisco Talos Blog
Cisco Talos Blog
C
Cybersecurity and Infrastructure Security Agency CISA
AWS News Blog
AWS News Blog
V
Vulnerabilities – Threatpost
J
Java Code Geeks
U
Unit 42
The GitHub Blog
The GitHub Blog
H
Help Net Security
T
Tenable Blog
aimingoo的专栏
aimingoo的专栏
Jina AI
Jina AI
Spread Privacy
Spread Privacy
Apple Machine Learning Research
Apple Machine Learning Research
人人都是产品经理
人人都是产品经理
L
Lohrmann on Cybersecurity
T
Threatpost
让小产品的独立变现更简单 - ezindie.com
让小产品的独立变现更简单 - ezindie.com
Engineering at Meta
Engineering at Meta
A
About on SuperTechFans
I
InfoQ
Microsoft Azure Blog
Microsoft Azure Blog
B
Blog
L
LINUX DO - 最新话题
K
Kaspersky official blog
cs.CV updates on arXiv.org
cs.CV updates on arXiv.org
T
Threat Research - Cisco Blogs
C
Check Point Blog
T
The Blog of Author Tim Ferriss
有赞技术团队
有赞技术团队
宝玉的分享
宝玉的分享
Help Net Security
Help Net Security
Google DeepMind News
Google DeepMind News
A
Arctic Wolf
Y
Y Combinator Blog
N
News | PayPal Newsroom
M
MIT News - Artificial intelligence
Latest news
Latest news
H
Hacker News: Front Page
Blog — PlanetScale
Blog — PlanetScale
腾讯CDC
I
Intezer
爱范儿
爱范儿
F
Fortinet All Blogs
P
Palo Alto Networks Blog
C
CERT Recently Published Vulnerability Notes

博客园 - 老管

freebsd.org改版 安装lilina续 - 更改首页显示天数 不重启更新rc.conf socks5-v1.0r11.tar.gz安装笔记 在线rss阅读聚合器lilina-0.7安装笔记 设置CMOS使服务器断电来电后自动开机 使win2003自动登陆 freebsd下安装GIMP FreeBSD5.4Release中文工作站安装笔记 (Freebsd5.4R+Gnome2.10.0) 《freebsd下gdm的安装》续 freebsd下gdm的安装 安装freebsd后win2000不能进入 vsmon.exe进程对CPU资源的占用问题 FreeBSD代理服务器(proxy)的“改造” 找出windows2000的boot.ini文件 不重启机器的情况下重启rc.conf 突然断电导致freebsd服务器文件系统检测错误-fsck 代理服务器又出现mbuf clusters exhausted 故障 .. 关于squid禁止某些站点的访问的控制 (acl语句)
一次网络故障的排除-都是3COM光纤模块惹的祸
老管 · 2005-07-09 · via 博客园 - 老管

这学期刚开始几天,学校校园网基本正常,唯独网络中心至图书馆之间经常数据包丢失(如下),影响了图书馆的正常工作(借还书、采编、阅览室)。具体如下:

网络环境:校园局域网,建筑物间光纤100MInternet入口电信10M

网络故障: 图书馆至网络中心之间通信时经常丢包,从网络中心向图书馆ping时情况如下:

C:\Documents and Settings\freebsd>ping 192.168.20.3 -t

Pinging 192.168.20.31 with 32 bytes of data:

Reply from 192.168.20.31: bytes=32 time<1ms TTL=128

Request timed out.

Reply from 192.168.20.31: bytes=32 time<1ms TTL=128

Reply from 192.168.20.31: bytes=32 time<1ms TTL=128

Request timed out.

Request timed out.

Request timed out.

Reply from 192.168.20.31: bytes=32 time<1ms TTL=128

Reply from 192.168.20.31: bytes=32 time<1ms TTL=128

Reply from 192.168.20.31: bytes=32 time<1ms TTL=128

Reply from 192.168.20.31: bytes=32 time<1ms TTL=128

Request timed out.

Reply from 192.168.20.31: bytes=32 time<1ms TTL=128

Reply from 192.168.20.31: bytes=32 time<1ms TTL=128

网络拓扑:图书馆至网络中心拓扑图如下

排除方法1 网络中心这边维持不动,将图书馆的3COM4400交换机上接到图书馆的办公用机、采编室、阅览室的网线全部拔下,然后拿一台笔记本用一根双绞线单独连到交换机上,在用笔记本ping网络中心的机器,故障依旧。刚开始是怀疑图书馆的机器中蠕虫病毒,现在可以肯定图书馆的所有用机均正常。

排除方法2 将网络中心和图书馆两边的3COM交换机上连接的网线都拔下,然后各自连接一台笔记本,从一台ping另一台笔记本,故障依旧。可以断定网络中心上连接的计算机也没问题。

排除方法3  经过上两次排除后,可以断定是光纤或光纤熔接盒或者3COM交换机的问题。

先检查两建筑物之间的光纤和光纤熔接盒里的光纤熔接情况,特请了熔接光纤的人过来看了,说两建筑物间的光纤没问题,但两头光纤熔接盒里的耦合器有松动,而且材质是铜的,通信质量不好,所以换了四个新的材质是陶瓷的耦合器,然后按照排除方法2进行ping但故障依旧

排除方法4 这一次将怀疑目标定在了3COM交换机上,我们用了两对D-LINK的光纤转换器,将耦合器两头出来的尾纤分别连接到D-LINK光纤转换器的光纤端口,然后从两个光纤转换器上的双绞线接口上分别接出两根双绞线连接到两台笔记本上(如下网络拓扑图),

然后开始ping没有丢包,故障排除!!!然后将网络中心这边恢复正常,然后从图书馆这边的笔记本ping网络中心的网管机,没有丢包;接着将图书馆这的D-LINK光纤转换器上的直接接在笔记本上的双绞线接到3COM交换机的双绞线口上,然后再用双绞线将笔记本和交换机连接,再用笔记本ping网络中心的网管机,也正常,没有丢包。这说明两建筑物间光纤及光纤熔接器及尾纤都没有问题。

总结:从上两张网络拓扑图中可以看出,不同处就在于省略了两个3COM交换机下的光纤模块,问题肯定是出在了光纤模块上了,我记得一块光纤模块和一台3COM交换机的价钱都差不多,怎么就发生在它身上。