惯性聚合 高效追踪和阅读你感兴趣的博客、新闻、科技资讯
阅读原文 在惯性聚合中打开

推荐订阅源

Microsoft Azure Blog
Microsoft Azure Blog
博客园_首页
Forbes - Security
Forbes - Security
WordPress大学
WordPress大学
P
Proofpoint News Feed
T
Threat Research - Cisco Blogs
L
LINUX DO - 热门话题
L
Lohrmann on Cybersecurity
Spread Privacy
Spread Privacy
D
Darknet – Hacking Tools, Hacker News & Cyber Security
大猫的无限游戏
大猫的无限游戏
博客园 - 三生石上(FineUI控件)
P
Privacy International News Feed
A
About on SuperTechFans
T
Tailwind CSS Blog
I
InfoQ
S
Securelist
云风的 BLOG
云风的 BLOG
罗磊的独立博客
Recent Announcements
Recent Announcements
T
The Exploit Database - CXSecurity.com
B
Blog RSS Feed
V
Visual Studio Blog
Know Your Adversary
Know Your Adversary
The GitHub Blog
The GitHub Blog
Jina AI
Jina AI
腾讯CDC
Cyberwarzone
Cyberwarzone
有赞技术团队
有赞技术团队
AWS News Blog
AWS News Blog
博客园 - 【当耐特】
cs.AI updates on arXiv.org
cs.AI updates on arXiv.org
F
Full Disclosure
S
Secure Thoughts
博客园 - 司徒正美
J
Java Code Geeks
Y
Y Combinator Blog
Google Online Security Blog
Google Online Security Blog
GbyAI
GbyAI
N
News and Events Feed by Topic
Help Net Security
Help Net Security
freeCodeCamp Programming Tutorials: Python, JavaScript, Git & More
Project Zero
Project Zero
T
Tenable Blog
cs.CV updates on arXiv.org
cs.CV updates on arXiv.org
T
Tor Project blog
MyScale Blog
MyScale Blog
Scott Helme
Scott Helme
小众软件
小众软件
K
Kaspersky official blog

Proxmox Support Forum

[SOLVED] - Github Auth for Mirrors-Kernel Repo? [Automation] Mass migration tool for MS Win11/Server Proxmox GUI hang - not response is it possible to reject or quarantine spam based on conditions I set ? The PVENode task list in PVE9 is partially obscured due to the terminal font being too large. About 100% error reporting due to pveproxy.service hooks Kubernetes overlay networking breaks when upgrading from PVE 9.1 to PVE 9.2.3 Zentraler Speicher No space left on device Combine datastore and direct file archival to tape Kernel panic VFS: Unable to mount root fs on unknown-block (0,0) sobald ein 7.x Kernel verwendet wird. How to migrate disk of a VM from one ZFS to another Windows Server 2025 fails to boot after PVE 9.2 / Linux 7.0 Kernel upgrade Cannot Install Proxmox on T610 Poweredge with H700 PERC card sdn Config. gateway not reachable How to safely change domain/FQDN? Welche Filterquote erreicht ihr? NFS Share status unknown on 2 of 5 nodes Can't connect to PVE9 consoles [solved] Can't connect to PVE9 consoles [solved] [SOLVED] - Use secondary network for PVE commands Created cluster, one node storage gone BUG: proxmox mail gateway FROM = null bypass spam filtering Moving existing PBS from VMWare workstation to PVE cluster Does eBGP SDN fabric support external peering? Bug: PDM 1.1 not recognizing valid license status Proxmox GUI hang - not response PVE crashes unexpectedly Proxmox Backup Server 4.2 released! Advice ceph-osd crashes with kernel 6.17.2-1-pve on Dell system [META] Links on Proxmox Forum Website Hardwarer oder Software RAID Joining a cluster with already created guests VM PDM missing backup jobs from PVE / Log retention Remove VM.Monitor from all users/roles, PVE 9.2 Proxmox Freezing (new instalation) 9.2.2 - Intel 12700T No Web gui and random connection reset by peer [SOLVED] - i40e module for X710 Intel NIC Dutch Proxmox Day 2026 How pools use the space Corosync initiiert Reboot trotz Verfügbarkeit der Systeme Opt-in Linux 7.0 Kernel for Proxmox VE 9 available After PVE 8to9 upgrade, unable to check guest fs freeze status Problem with MegaRAID SAS3508 controller proxmox-kernel-7.0.2-6-pve failing network service Auto sync guest time after rollback of VM snapshot with RAM/state Broadcom BCM57504 (100G) bnxt_en TX timeout and NIC reset on Proxmox 8.1.5 — while BCM57414 (25G) works fine on same host QEMU 11.0 available on pve-test and pve-no-subscription as of now 350 MPM Solventless Lamination Machine for High-Speed Flexible Packaging Making sense of NVMe zfs and SMART errors [SOLVED] - PVE loses network connection after kernel upgrade to proxmox-kernel-7.0.0-3-pve [SOLVED] - Remove or reset cluster configuration. Proxmox 8.4.1 Fresh Install BCM57416 10G Ethernet Adapter Not Recognized PDM 1.1.1 unable to add AD realm with anonymous search [TUTORIAL] - Developer Workstation (Proxmox-VE 9) with cinnamon (LMDE7) SDN zone shows "pending" on peer nodes after node reboot (9.2.x) Cluster not quorate - extending auth key lifetime! Proxmox not rebooting properly (SOLVED) Proxmox 9 Stuck on loading initial ramdisk With new HA-Disarm Feature is there a Documentation for NUT Setup on Clusters? Proxmox 8.3 Installation Issue on ProLiant DL380 Gen9 Cluster networking setup LXC System images unavailable [SOLVED] - Fix: NVIDIA Drivers Failing after upgrade to Proxmox 9.2.2 (Kernel 7.0.2-6-pve) / NovaCore Conflict Install NUT directly on Proxmox VE and control guests from here driver usb for windows 7 System startup error and no network: Failed to start ifupdown2-pre.service - Helper to synchronize boot up for ifupdown. PBS backup space grow up constantly Proxmox Datacenter Manager 1.1 released! IPv4 not available in newly created VM Recommended Setup for Offsite Proxmox Backups? Hetzner Storage Box & Remote PBS Challenges duplicate, please delete this passthrought an USB device "by ID" to CT PDM Installer Freezes at 66% Tried PDM for the first time (version 1.1) - had issues PDM 1.1 automated install Suche Server-Provider für Proxmox connecting sdn to edge firewall SDN, IPAM & DHCP Migrating from read-only file system Ubuntu 26.04 installation fails for unknown reason Status Unbekannt nach Cluster Join Installing Proxmox Backup Server on Mac Mini (Late 2012) kernel 7.0 performance issue with zfs pools PVE becomes unreachable via ethernet but OS is running [SOLVED] - New 9.2 install - can't find 7.0.2-6-pve , not all the time [SOLVED] - Backup and dedupe a VM with LUKS Gibt es mit PVE 2.x ggf. Änderungen bei der RAM-Nutzung, bzw. deren Anzeige bei VMs? I need help for setting up backup solution Way more NAGware, very little functionality, bugs galore Root squashing virtiofsd with --uid-map Intel ixgbe Driver Update Fail Passkey Login (not 2FA) Roblox VM detection - can be overcome? [TUTORIAL] - ZFS-Autosnaptshot inkl. Rollback und Daten direkt recovern (Windows/Linux) How to stop PVE Kernel upgrade [SOLVED] - very long waiting to log in to lxc debian 11 ssh [TUTORIAL] - Configuring Fusion-Io (SanDisk) ioDrive, ioDrive2, ioScale and ioScale2 cards with Proxmox Increase maximum USB devices in vm.conf
PCIe Passthrough crashes host
invalid@exam · 2026-06-15 · via Proxmox Support Forum

As requested [here](https://forum.proxmox.com/threads/opt-in-linux-7-0-kernel-for-proxmox-ve-9-available.182328/post-855630) PCIe Passthrough issues should be posted in a new thread. Therefore here:

Can also confirm that the Kernel 7.0 contains a regression related PCIe Passthrough.

With a fully patched Proxmox 9.2.3 (no-subscription) PCIe Passthrough with our Nvidia 5090 works fine with the Kernel 6.17.13-13-pve. But when we booting Proxmox with 7.0.6-2-pve Proxmox starts fine - until the VM starts with the PCIe Passthrough setting. In this case I can't even reach the server anymore via ssh.

Output of lspci -v -nn with 6.17.13-13:

Code:

41:00.0 VGA compatible controller [0300]: NVIDIA Corporation GB202 [GeForce RTX 5090] [10de:2b85] (rev a1) (prog-if 00 [VGA controller])
        Subsystem: InnoVISION Multimedia Ltd. Device [1771:2059]
        Flags: bus master, fast devsel, latency 0, IRQ 327, NUMA node 0, IOMMU group 63
        Memory at b4000000 (32-bit, non-prefetchable) [size=64M]
        Memory at 80120000000 (64-bit, prefetchable) [size=256M]
        Memory at 80130000000 (64-bit, prefetchable) [size=32M]
        I/O ports at 6000 [size=128]
        Expansion ROM at b8000000 [disabled] [size=512K]
        Capabilities: [40] Power Management version 3
        Capabilities: [48] MSI: Enable- Count=1/16 Maskable+ 64bit+
        Capabilities: [60] Express Legacy Endpoint, IntMsgNum 0
        Capabilities: [9c] Vendor Specific Information: Len=14 <?>
        Capabilities: [b0] MSI-X: Enable+ Count=9 Masked-
        Capabilities: [100] Secondary PCI Express
        Capabilities: [12c] Latency Tolerance Reporting
        Capabilities: [134] Physical Resizable BAR
        Capabilities: [140] Virtual Resizable BAR
        Capabilities: [14c] Data Link Feature <?>
        Capabilities: [158] Physical Layer 16.0 GT/s <?>
        Capabilities: [188] Physical Layer 32.0 GT/s <?>
        Capabilities: [1b8] Advanced Error Reporting
        Capabilities: [200] Lane Margining at the Receiver
        Capabilities: [248] Alternative Routing-ID Interpretation (ARI)
        Capabilities: [250] Single Root I/O Virtualization (SR-IOV)
        Capabilities: [290] L1 PM Substates
        Capabilities: [2a4] Vendor Specific Information: ID=0001 Rev=1 Len=014 <?>
        Capabilities: [2bc] Power Budgeting <?>
        Capabilities: [2f4] Device Serial Number 7d-12-38-17-f5-2d-b0-48
        Kernel driver in use: vfio-pci
        Kernel modules: nvidiafb, nouveau

With 7.0.6-2-pve & 7.0.2-4-pve:

Code:

41:00.0 VGA compatible controller [0300]: NVIDIA Corporation GB202 [GeForce RTX 5090] [10de:2b85] (rev a1) (prog-if 00 [VGA controller])
        Subsystem: InnoVISION Multimedia Ltd. Device [1771:2059]
        Flags: bus master, fast devsel, latency 0, IRQ 11, NUMA node 0, IOMMU group 63
        Memory at b4000000 (32-bit, non-prefetchable) [size=64M]
        Memory at 80120000000 (64-bit, prefetchable) [size=256M]
        Memory at 80130000000 (64-bit, prefetchable) [size=32M]
        I/O ports at 6000 [size=128]
        Expansion ROM at b8000000 [disabled] [size=512K]
        Capabilities: [40] Power Management version 3
        Capabilities: [48] MSI: Enable- Count=1/16 Maskable+ 64bit+
        Capabilities: [60] Express Legacy Endpoint, IntMsgNum 0
        Capabilities: [9c] Vendor Specific Information: Len=14 <?>
        Capabilities: [b0] MSI-X: Enable- Count=9 Masked-
        Capabilities: [100] Secondary PCI Express
        Capabilities: [12c] Latency Tolerance Reporting
        Capabilities: [134] Physical Resizable BAR
        Capabilities: [140] Virtual Resizable BAR
        Capabilities: [14c] Data Link Feature <?>
        Capabilities: [158] Physical Layer 16.0 GT/s <?>
        Capabilities: [188] Physical Layer 32.0 GT/s <?>
        Capabilities: [1b8] Advanced Error Reporting
        Capabilities: [200] Lane Margining at the Receiver
        Capabilities: [248] Alternative Routing-ID Interpretation (ARI)
        Capabilities: [250] Single Root I/O Virtualization (SR-IOV)
        Capabilities: [290] L1 PM Substates
        Capabilities: [2a4] Vendor Specific Information: ID=0001 Rev=1 Len=014 <?>
        Capabilities: [2bc] Power Budgeting <?>
        Capabilities: [2f4] Device Serial Number 7d-12-38-17-f5-2d-b0-48
        Kernel modules: nvidiafb, nouveau, nova_core

Content of /etc/modprobe.d/vfio.conf:

Code:

options vfio-pci ids=10de:2b85,10de:22e8 disable_vga=1

Content of /etc/modprobe.d/blacklist.conf:

Code:

blacklist nova
blacklist nova_core
blacklist nvidia
blacklist nvidia_drm
blacklist nvidia_modeset
blacklist nouveau

As dmesg | grep -i vfio didn't showed anything I adjusted the /etc/modules-load.d/vfio.conf:

Code:

vfio
vfio_pci
vfio_iommu_type1
vfio_virqfd

After update-initramfs -u & reboot I got finally the line Kernel driver in use: vfio-pci with Kernel 7.0.x, but the VM is still crashing the host:

Code:

        Kernel driver in use: vfio-pci
        Kernel modules: nvidiafb, nouveau, nova_core

Should be already tracked here: https://bugzilla.proxmox.com/show_bug.cgi?id=7548

Last edited:

Just in case someone else has the issue: The issue was, that our VM had used a BIOS instead of UEFI. After changing this (and disabling Secure Boot) it worked also with the new Kernel.