惯性聚合 高效追踪和阅读你感兴趣的博客、新闻、科技资讯
阅读原文 在惯性聚合中打开

推荐订阅源

Blog — PlanetScale
Blog — PlanetScale
SecWiki News
SecWiki News
Google DeepMind News
Google DeepMind News
WordPress大学
WordPress大学
小众软件
小众软件
C
CERT Recently Published Vulnerability Notes
Jina AI
Jina AI
N
Netflix TechBlog - Medium
GbyAI
GbyAI
IT之家
IT之家
Apple Machine Learning Research
Apple Machine Learning Research
AWS News Blog
AWS News Blog
G
GRAHAM CLULEY
L
Lohrmann on Cybersecurity
C
Cybersecurity and Infrastructure Security Agency CISA
I
Intezer
T
Tor Project blog
P
Palo Alto Networks Blog
P
Privacy & Cybersecurity Law Blog
P
Privacy International News Feed
Threat Intelligence Blog | Flashpoint
Threat Intelligence Blog | Flashpoint
P
Proofpoint News Feed
T
Tailwind CSS Blog
C
Check Point Blog
Cloudbric
Cloudbric
Y
Y Combinator Blog
The Last Watchdog
The Last Watchdog
Forbes - Security
Forbes - Security
Last Week in AI
Last Week in AI
S
Security Affairs
博客园 - Franky
F
Fortinet All Blogs
量子位
M
MIT News - Artificial intelligence
C
Cisco Blogs
酷 壳 – CoolShell
酷 壳 – CoolShell
Stack Overflow Blog
Stack Overflow Blog
S
Secure Thoughts
V
Visual Studio Blog
AI
AI
美团技术团队
B
Blog RSS Feed
Application and Cybersecurity Blog
Application and Cybersecurity Blog
博客园 - 三生石上(FineUI控件)
阮一峰的网络日志
阮一峰的网络日志
Engineering at Meta
Engineering at Meta
人人都是产品经理
人人都是产品经理
Microsoft Security Blog
Microsoft Security Blog
T
Threatpost
Cyberwarzone
Cyberwarzone

Proxmox Support Forum

[SOLVED] - Github Auth for Mirrors-Kernel Repo? [Automation] Mass migration tool for MS Win11/Server Proxmox GUI hang - not response is it possible to reject or quarantine spam based on conditions I set ? The PVENode task list in PVE9 is partially obscured due to the terminal font being too large. About 100% error reporting due to pveproxy.service hooks Kubernetes overlay networking breaks when upgrading from PVE 9.1 to PVE 9.2.3 Zentraler Speicher No space left on device Combine datastore and direct file archival to tape Kernel panic VFS: Unable to mount root fs on unknown-block (0,0) sobald ein 7.x Kernel verwendet wird. How to migrate disk of a VM from one ZFS to another Windows Server 2025 fails to boot after PVE 9.2 / Linux 7.0 Kernel upgrade Cannot Install Proxmox on T610 Poweredge with H700 PERC card sdn Config. gateway not reachable How to safely change domain/FQDN? Welche Filterquote erreicht ihr? NFS Share status unknown on 2 of 5 nodes Can't connect to PVE9 consoles [solved] Can't connect to PVE9 consoles [solved] [SOLVED] - Use secondary network for PVE commands Created cluster, one node storage gone BUG: proxmox mail gateway FROM = null bypass spam filtering Moving existing PBS from VMWare workstation to PVE cluster Does eBGP SDN fabric support external peering? Bug: PDM 1.1 not recognizing valid license status Proxmox GUI hang - not response PVE crashes unexpectedly Proxmox Backup Server 4.2 released! Advice ceph-osd crashes with kernel 6.17.2-1-pve on Dell system [META] Links on Proxmox Forum Website Hardwarer oder Software RAID Joining a cluster with already created guests VM PDM missing backup jobs from PVE / Log retention Remove VM.Monitor from all users/roles, PVE 9.2 Proxmox Freezing (new instalation) 9.2.2 - Intel 12700T No Web gui and random connection reset by peer [SOLVED] - i40e module for X710 Intel NIC Dutch Proxmox Day 2026 How pools use the space Corosync initiiert Reboot trotz Verfügbarkeit der Systeme Opt-in Linux 7.0 Kernel for Proxmox VE 9 available After PVE 8to9 upgrade, unable to check guest fs freeze status Problem with MegaRAID SAS3508 controller proxmox-kernel-7.0.2-6-pve failing network service Auto sync guest time after rollback of VM snapshot with RAM/state Broadcom BCM57504 (100G) bnxt_en TX timeout and NIC reset on Proxmox 8.1.5 — while BCM57414 (25G) works fine on same host QEMU 11.0 available on pve-test and pve-no-subscription as of now 350 MPM Solventless Lamination Machine for High-Speed Flexible Packaging Making sense of NVMe zfs and SMART errors [SOLVED] - PVE loses network connection after kernel upgrade to proxmox-kernel-7.0.0-3-pve [SOLVED] - Remove or reset cluster configuration. Proxmox 8.4.1 Fresh Install BCM57416 10G Ethernet Adapter Not Recognized PDM 1.1.1 unable to add AD realm with anonymous search [TUTORIAL] - Developer Workstation (Proxmox-VE 9) with cinnamon (LMDE7) SDN zone shows "pending" on peer nodes after node reboot (9.2.x) Cluster not quorate - extending auth key lifetime! Proxmox not rebooting properly (SOLVED) Proxmox 9 Stuck on loading initial ramdisk With new HA-Disarm Feature is there a Documentation for NUT Setup on Clusters? Proxmox 8.3 Installation Issue on ProLiant DL380 Gen9 Cluster networking setup LXC System images unavailable [SOLVED] - Fix: NVIDIA Drivers Failing after upgrade to Proxmox 9.2.2 (Kernel 7.0.2-6-pve) / NovaCore Conflict Install NUT directly on Proxmox VE and control guests from here driver usb for windows 7 System startup error and no network: Failed to start ifupdown2-pre.service - Helper to synchronize boot up for ifupdown. PBS backup space grow up constantly Proxmox Datacenter Manager 1.1 released! IPv4 not available in newly created VM Recommended Setup for Offsite Proxmox Backups? Hetzner Storage Box & Remote PBS Challenges duplicate, please delete this passthrought an USB device "by ID" to CT PDM Installer Freezes at 66% Tried PDM for the first time (version 1.1) - had issues PDM 1.1 automated install Suche Server-Provider für Proxmox connecting sdn to edge firewall SDN, IPAM & DHCP Migrating from read-only file system Ubuntu 26.04 installation fails for unknown reason Status Unbekannt nach Cluster Join Installing Proxmox Backup Server on Mac Mini (Late 2012) kernel 7.0 performance issue with zfs pools PVE becomes unreachable via ethernet but OS is running [SOLVED] - New 9.2 install - can't find 7.0.2-6-pve , not all the time [SOLVED] - Backup and dedupe a VM with LUKS Gibt es mit PVE 2.x ggf. Änderungen bei der RAM-Nutzung, bzw. deren Anzeige bei VMs? I need help for setting up backup solution Way more NAGware, very little functionality, bugs galore Root squashing virtiofsd with --uid-map Intel ixgbe Driver Update Fail Passkey Login (not 2FA) Roblox VM detection - can be overcome? [TUTORIAL] - ZFS-Autosnaptshot inkl. Rollback und Daten direkt recovern (Windows/Linux) How to stop PVE Kernel upgrade [SOLVED] - very long waiting to log in to lxc debian 11 ssh [TUTORIAL] - Configuring Fusion-Io (SanDisk) ioDrive, ioDrive2, ioScale and ioScale2 cards with Proxmox Increase maximum USB devices in vm.conf
High CPU use on systemd-journal caused by proxmox-datacenter-api
invalid@exam · 2026-06-17 · via Proxmox Support Forum

Code:

## COMMANDS

 $ `date -R`
```
Wed, 17 Jun 2026 14:08:59 +0200
```

$ `proxmox-datacenter-manager-admin versions --verbose`
```
proxmox-datacenter-manager-meta      1.1.0         running kernel: 7.0.6-2-pve
proxmox-datacenter-manager           1.1.4         running version: 1.1.4    
proxmox-kernel-helper                9.2.0                                  
proxmox-kernel-7.0                   7.0.6-2                                
proxmox-kernel-7.0.6-2-pve-signed    7.0.6-2                                
proxmox-kernel-7.0.2-2-pve-signed    7.0.2-2                                
proxmox-kernel-6.17                  6.17.13-13                              
proxmox-kernel-6.17.13-13-pve-signed 6.17.13-13                              
proxmox-kernel-6.17.2-2-pve-signed   6.17.2-2                                
ifupdown2                            3.3.0-1+pmx12                          
proxmox-mail-forward                 1.0.3                                  
proxmox-mini-journalreader           1.6                                    
proxmox-offline-mirror-helper        0.7.4                                  
pve-xtermjs                          6.0.0-1                                
zfsutils-linux                       2.4.2-pve1
```

$ `proxmox-datacenter-manager-admin remote list`
```
Proxmox VE node sol-pve01:
    auth id: root@pam!pdm-admin-datacenter
    token:
    node: sol-pve01.REDACTED.lan:443
Proxmox VE node HomeLab:
    auth id: root@pam!pdm-admin-datacenter
    token:
    nodes:
        pve1.proxmox.lan:443,fingerprint=REDACTED
        pve2.proxmox.lan:443,fingerprint=REDACTED
        pve3.proxmox.lan
Proxmox Backup Server node sol-pbs01:
    auth id: root@pam!pdm-admin-datacenter
    token:
    node: sol-pbs01.REDACTED.lan,fingerprint=REDACTED
Proxmox VE node net1:
    auth id: root@pam!pdm-admin-datacenter
    token:
    node: net1.proxmox.lan,fingerprint=REDACTED
```

$ `proxmox-datacenter-manager-admin remote subscriptions`
```
Remote sol-pve01 subscription status: None
    node sol-pve01: status=notfound,sockets=2,level=None

Remote HomeLab subscription status: None
    node pve2: status=notfound,sockets=1,level=None
    node pve3: status=notfound,sockets=1,level=None
    node pve1: status=notfound,sockets=1,level=None

Remote sol-pbs01 subscription status: None
    node localhost: status=notfound,level=None

Remote net1 subscription status: None
    node net1: status=notfound,sockets=1,level=None
```

$ `proxmox-datacenter-manager-admin support-status get`
```
┌─────────┬────────────────────────────────────────────────────────────────────┐
│ Name    │ Value                                                              │
╞═════════╪════════════════════════════════════════════════════════════════════╡
│ status  │ invalid                                                            │
├─────────┼────────────────────────────────────────────────────────────────────┤
│ message │ Too many remote nodes without active basic or higher subscription! │
├─────────┼────────────────────────────────────────────────────────────────────┤
│ url     │ https://pdm.proxmox.com/faq.html                                   │
└─────────┴────────────────────────────────────────────────────────────────────┘
```

$ `proxmox-boot-tool status`
```
Re-executing '/sbin/proxmox-boot-tool' in new private mount namespace..
```
STDERR:
```
E: /etc/kernel/proxmox-boot-uuids does not exist.

```

$ `df -h -T`
```
Filesystem           Type      Size  Used Avail Use% Mounted on
udev                 devtmpfs  590M     0  590M   0% /dev
tmpfs                tmpfs     105M  668K  105M   1% /run
/dev/mapper/pdm-root ext4      8.3G  5.8G  2.1G  74% /
tmpfs                tmpfs     522M     0  522M   0% /dev/shm
tmpfs                tmpfs     5.0M     0  5.0M   0% /run/lock
tmpfs                tmpfs     1.0M     0  1.0M   0% /run/credentials/systemd-journald.service
tmpfs                tmpfs     522M     0  522M   0% /tmp
tmpfs                tmpfs     1.0M     0  1.0M   0% /run/credentials/getty@tty1.service
```

$ `lsblk --ascii -M -o +HOTPLUG,ROTA,PHY-SEC,FSTYPE,MODEL,TRAN`
```
NAME         MAJ:MIN RM  SIZE RO TYPE MOUNTPOINTS HOTPLUG ROTA PHY-SEC FSTYPE      MODEL         TRAN
sda            8:0    0   10G  0 disk                   0    1     512             QEMU HARDDISK
|-sda1         8:1    0 1007K  0 part                   0    1     512                          
|-sda2         8:2    0  512M  0 part                   0    1     512 vfat                    
`-sda3         8:3    0  9.5G  0 part                   0    1     512 LVM2_member              
  |-pdm-swap 252:0    0    1G  0 lvm  [SWAP]            0    1     512 swap                    
  `-pdm-root 252:1    0  8.5G  0 lvm  /                 0    1     512 ext4                    
sr0           11:0    1 1024M  0 rom                    0    0     512             QEMU DVD-ROM  ata
```

$ `ls -l /dev/disk/by-id /dev/disk/by-path`
```
/dev/disk/by-id:
total 0
lrwxrwxrwx 1 root root  9 Jun 17 14:03 ata-QEMU_DVD-ROM_QM00003 -> ../../sr0
lrwxrwxrwx 1 root root 10 Jun 17 14:03 dm-name-pdm-root -> ../../dm-1
lrwxrwxrwx 1 root root 10 Jun 17 14:03 dm-name-pdm-swap -> ../../dm-0
lrwxrwxrwx 1 root root 10 Jun 17 14:03 dm-uuid-LVM-9FyG74IRIz45StsncMUgC7V72q4BwaG36Z5VBz4qTwTad1Mte50afz9lzgVBjjKa -> ../../dm-0
lrwxrwxrwx 1 root root 10 Jun 17 14:03 dm-uuid-LVM-9FyG74IRIz45StsncMUgC7V72q4BwaG3Pm2KlwPNWAelb8jpAxlpFP4fOln9HJlc -> ../../dm-1
lrwxrwxrwx 1 root root 10 Jun 17 14:03 lvm-pv-uuid-Lfgkx8-eqGe-uZrB-f94K-L0QP-ZFro-qgc1k5 -> ../../sda3
lrwxrwxrwx 1 root root  9 Jun 17 14:03 scsi-0QEMU_QEMU_HARDDISK_drive-scsi0 -> ../../sda
lrwxrwxrwx 1 root root 10 Jun 17 14:03 scsi-0QEMU_QEMU_HARDDISK_drive-scsi0-part1 -> ../../sda1
lrwxrwxrwx 1 root root 10 Jun 17 14:03 scsi-0QEMU_QEMU_HARDDISK_drive-scsi0-part2 -> ../../sda2
lrwxrwxrwx 1 root root 10 Jun 17 14:03 scsi-0QEMU_QEMU_HARDDISK_drive-scsi0-part3 -> ../../sda3

/dev/disk/by-path:
total 0
lrwxrwxrwx 1 root root   9 Jun 17 14:03 pci-0000:00:01.1-ata-2 -> ../../sr0
lrwxrwxrwx 1 root root   9 Jun 17 14:03 pci-0000:00:01.1-ata-2.0 -> ../../sr0
lrwxrwxrwx 1 root root   9 Jun 17 14:03 pci-0000:01:01.0-scsi-0:0:0:0 -> ../../sda
drwxr-xr-x 5 root root 100 Jun 17 14:03 pci-0000:01:01.0-scsi-0:0:0:0-part
lrwxrwxrwx 1 root root  10 Jun 17 14:03 pci-0000:01:01.0-scsi-0:0:0:0-part1 -> ../../sda1
lrwxrwxrwx 1 root root  10 Jun 17 14:03 pci-0000:01:01.0-scsi-0:0:0:0-part2 -> ../../sda2
lrwxrwxrwx 1 root root  10 Jun 17 14:03 pci-0000:01:01.0-scsi-0:0:0:0-part3 -> ../../sda3
```

$ `zpool status`
```

```
STDERR:
```
no pools available

```

$ `zfs list`
```

```
STDERR:
```
no datasets available

```

$ `zarcstat `
```
    time  read  ddread  ddh%  dmread  dmh%  pread  ph%   size      c  avail
14:08:59     0       0     0       0     0      0    0    960  32.6M   1.3G
```

$ `ip -details -statistics address`
```
1: lo: <LOOPBACK,UP,LOWER_UP> mtu 65536 qdisc noqueue state UNKNOWN group default qlen 1000
    link/loopback 00:00:00:00:00:00 brd 00:00:00:00:00:00 promiscuity 0 allmulti 0 minmtu 0 maxmtu 0 numtxqueues 1 numrxqueues 1 gso_max_size 65536 gso_max_segs 65535 tso_max_size 524280 tso_max_segs 65535 gro_max_size 65536 gso_ipv4_max_size 65536 gro_ipv4_max_size 65536
    inet 127.0.0.1/8 scope host lo
       valid_lft forever preferred_lft forever
    inet6 ::1/128 scope host noprefixroute
       valid_lft forever preferred_lft forever
    RX:  bytes packets errors dropped  missed   mcast          
       7570730    4581      0       0       0       0
    TX:  bytes packets errors dropped carrier collsns          
       7570730    4581      0       0       0       0
2: nic0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc fq_codel state UP group default qlen 1000
    link/ether bc:24:11:3e:c6:d0 brd ff:ff:ff:ff:ff:ff promiscuity 0 allmulti 0 minmtu 68 maxmtu 1500 numtxqueues 1 numrxqueues 1 gso_max_size 65536 gso_max_segs 65535 tso_max_size 65536 tso_max_segs 65535 gro_max_size 65536 gso_ipv4_max_size 65536 gro_ipv4_max_size 65536 parentbus virtio parentdev virtio2
    altname enp0s18
    altname enxbc24113ec6d0
    inet 192.168.1.48/24 scope global nic0
       valid_lft forever preferred_lft forever
    inet6 fe80::be24:11ff:fe3e:c6d0/64 scope link proto kernel_ll
       valid_lft forever preferred_lft forever
    RX:  bytes packets errors dropped  missed   mcast          
       1174530    2967      0       0       0       0
    TX:  bytes packets errors dropped carrier collsns          
       6441064    2293      0      11       0       0
```

$ `ip -4 route show`
```
default via 192.168.1.1 dev nic0 proto kernel onlink
192.168.1.0/24 dev nic0 proto kernel scope link src 192.168.1.48
```

$ `ip -6 route show`
```
fe80::/64 dev nic0 proto kernel metric 256 pref medium
```

## FUNCTIONS

#### System Load & Uptime
$ `top -b -c -w512 -n 1 -o TIME`
```
top - 14:08:59 up 5 min,  0 users,  load average: 1.28, 0.91, 0.42
Tasks: 121 total,   2 running, 119 sleeping,   0 stopped,   0 zombie
%Cpu(s): 39.1 us, 26.1 sy,  0.0 ni, 30.4 id,  0.0 wa,  0.0 hi,  4.3 si,  0.0 st
MiB Mem :   1966.2 total,   1305.0 free,    340.7 used,    462.1 buff/cache    
MiB Swap:   1044.0 total,   1044.0 free,      0.0 used.   1625.5 avail Mem

    PID USER      PR  NI    VIRT    RES    SHR S  %CPU  %MEM     TIME+ COMMAND
    242 root      20   0  280076 173640 172324 S  90.9   8.6   4:57.90 /usr/lib/systemd/systemd-journald
    662 www-data  20   0 1073160  84376  33332 S  27.3   4.2   1:39.96 /usr/libexec/proxmox/proxmox-datacenter-api
     12 root      20   0       0      0      0 I   0.0   0.0   0:01.29 [kworker/u8:0-events_power_efficient]
     15 root      20   0       0      0      0 R   0.0   0.0   0:01.18 [rcu_preempt]
      1 root      20   0   23660  14424  10896 S   0.0   0.7   0:01.00 /sbin/init
     45 root      20   0       0      0      0 I   0.0   0.0   0:00.63 [kworker/1:1-events_freezable]
     25 root      20   0       0      0      0 S   0.0   0.0   0:00.47 [ksoftirqd/1]
     14 root      20   0       0      0      0 S   0.0   0.0   0:00.32 [ksoftirqd/0]
    641 nginx     20   0   28444  11212   7960 S   0.0   0.6   0:00.30 nginx: worker process
     11 root      20   0       0      0      0 I   0.0   0.0   0:00.13 [kworker/0:1-events]
    264 root      20   0   37008  10456   7960 S   0.0   0.5   0:00.10 /usr/lib/systemd/systemd-udevd
    131 root      20   0       0      0      0 I   0.0   0.0   0:00.08 [kworker/0:2-events]
     69 root      20   0       0      0      0 I   0.0   0.0   0:00.05 [kworker/u8:5-events_power_efficient]
     35 root      20   0       0      0      0 I   0.0   0.0   0:00.04 [kworker/u8:1-async]
    552 root      20   0   18400   8532   7400 S   0.0   0.4   0:00.04 /usr/lib/systemd/systemd-logind
    648 root      20   0  256840  25344  20624 S   0.0   1.3   0:00.02 /usr/libexec/proxmox/proxmox-datacenter-privileged-api
     65 root      20   0       0      0      0 S   0.0   0.0   0:00.01 [scsi_eh_2]
     67 root      20   0       0      0      0 I   0.0   0.0   0:00.01 [kworker/u8:3-events_unbound]
    549 message+  20   0    8316   4716   4216 S   0.0   0.2   0:00.01 /usr/bin/dbus-daemon --system --address=systemd: --nofork --nopidfile --systemd-activation --syslog-only
      2 root      20   0       0      0      0 S   0.0   0.0   0:00.00 [kthreadd]
      3 root      20   0       0      0      0 S   0.0   0.0   0:00.00 [pool_workqueue_release]
      4 root       0 -20       0      0      0 I   0.0   0.0   0:00.00 [kworker/R-rcu_gp]
      5 root       0 -20       0      0      0 I   0.0   0.0   0:00.00 [kworker/R-sync_wq]
```

## FILES

### General System Info

`$ cat '/etc/hostname'`
```
datacenter
```

`$ cat '/etc/hosts'`
```
127.0.0.1 localhost.localdomain localhost
192.168.1.48 datacenter.lan datacenter

# The following lines are desirable for IPv6 capable hosts

::1     ip6-localhost ip6-loopback
fe00::0 ip6-localnet
ff00::0 ip6-mcastprefix
ff02::1 ip6-allnodes
ff02::2 ip6-allrouters
ff02::3 ip6-allhosts
```

`$ cat '/etc/network/interfaces'`
```
auto lo
iface lo inet loopback

auto nic0
iface nic0 inet static
    address 192.168.1.48/24
    gateway 192.168.1.1


source /etc/network/interfaces.d/*
```

`$ cat '/etc/apt/sources.list'`
```

```

`$ cat '/etc/apt/sources.list.d/proxmox.sources'`
```
Types: deb
URIs: http://download.proxmox.com/debian/pdm
Suites: trixie
Components: pdm-no-subscription
Signed-By: /usr/share/keyrings/proxmox-archive-keyring.gpg
```

`$ cat '/etc/apt/sources.list.d/nginx.list'`
```
deb [signed-by=/usr/share/keyrings/nginx-archive-keyring.gpg] http://nginx.org/packages/debian trixie nginx
```

`$ cat '/etc/apt/sources.list.d/debian.sources'`
```
Types: deb
URIs: http://deb.debian.org/debian/
Suites: trixie trixie-updates
Components: main contrib non-free-firmware
Signed-By: /usr/share/keyrings/debian-archive-keyring.gpg

Types: deb
URIs: http://security.debian.org/debian-security/
Suites: trixie-security
Components: main contrib non-free-firmware
Signed-By: /usr/share/keyrings/debian-archive-keyring.gpg
```

`$ cat '/etc/apt/sources.list.d/pdm-enterprise.sources'`
```
Types: deb
URIs: https://enterprise.proxmox.com/debian/pdm
Suites: trixie
Components: pdm-enterprise
Signed-By: /usr/share/keyrings/proxmox-archive-keyring.gpg
Enabled: false
```


`$ cat '/proc/pressure/io'`
```
some avg10=0.08 avg60=0.03 avg300=0.07 total=964343
full avg10=0.00 avg60=0.00 avg300=0.01 total=499661
```

`$ cat '/proc/pressure/cpu'`
```
some avg10=1.85 avg60=1.83 avg300=1.41 total=8524442
full avg10=0.00 avg60=0.00 avg300=0.00 total=0
```

`$ cat '/proc/pressure/memory'`
```
some avg10=0.00 avg60=0.00 avg300=0.00 total=0
full avg10=0.00 avg60=0.00 avg300=0.00 total=0
```


### User & Access

`$ cat '/etc/proxmox-datacenter-manager/access/user.cfg'`
```
user: root@pam
    email REDACTED

user: sergio@pam
    email REDACTED
    enable true
```

`$ cat '/etc/proxmox-datacenter-manager/access/acl.cfg'`
```
acl:1:/:sergio@pam:Administrator
```

### Others

`$ cat '/etc/proxmox-datacenter-manager/node.cfg'`
```
# file does not exist
```

`$ cat '/etc/proxmox-datacenter-manager/views.cfg'`
```
view: VMs
    include-all true
    layout {"layout":{"layout-type":"rows","rows":[[{"flex":1.0,"widget-type":"nodes","remote-type":"pve"},{"flex":1.0,"widget-type":"nodes","remote-type":"pbs"},{"flex":1.0,"widget-type":"guests"}],[{"flex":1.0,"widget-type":"guests","guest-type":"qemu"},{"flex":1.0,"widget-type":"guests","guest-type":"lxc"},{"flex":1.0,"widget-type":"pbs-datastores"}],[{"widget-type":"leaderboard","leaderboard-type":"guest-cpu"},{"widget-type":"leaderboard","leaderboard-type":"node-cpu"},{"widget-type":"leaderboard","leaderboard-type":"node-memory"}],[{"widget-type":"task-summary","grouping":"category"}]]}}
```