惯性聚合 高效追踪和阅读你感兴趣的博客、新闻、科技资讯
阅读原文 在惯性聚合中打开

推荐订阅源

V
Vulnerabilities – Threatpost
Hacker News: Ask HN
Hacker News: Ask HN
S
Schneier on Security
G
GRAHAM CLULEY
AWS News Blog
AWS News Blog
C
CERT Recently Published Vulnerability Notes
T
The Exploit Database - CXSecurity.com
P
Privacy International News Feed
Cyberwarzone
Cyberwarzone
Spread Privacy
Spread Privacy
cs.CL updates on arXiv.org
cs.CL updates on arXiv.org
T
Tor Project blog
月光博客
月光博客
M
MIT News - Artificial intelligence
Stack Overflow Blog
Stack Overflow Blog
E
Exploit-DB.com RSS Feed
V
V2EX
量子位
Apple Machine Learning Research
Apple Machine Learning Research
J
Java Code Geeks
C
Cisco Blogs
G
Google Developers Blog
GbyAI
GbyAI
C
Check Point Blog
云风的 BLOG
云风的 BLOG
Cisco Talos Blog
Cisco Talos Blog
Jina AI
Jina AI
P
Palo Alto Networks Blog
Cloudbric
Cloudbric
N
Netflix TechBlog - Medium
酷 壳 – CoolShell
酷 壳 – CoolShell
C
Cybersecurity and Infrastructure Security Agency CISA
S
Secure Thoughts
雷峰网
雷峰网
博客园 - 三生石上(FineUI控件)
P
Privacy & Cybersecurity Law Blog
O
OpenAI News
CTFtime.org: upcoming CTF events
CTFtime.org: upcoming CTF events
有赞技术团队
有赞技术团队
I
Intezer
Blog — PlanetScale
Blog — PlanetScale
Cyber Security Advisories - MS-ISAC
Cyber Security Advisories - MS-ISAC
Schneier on Security
Schneier on Security
Microsoft Security Blog
Microsoft Security Blog
D
DataBreaches.Net
Help Net Security
Help Net Security
S
Security Archives - TechRepublic
K
KPMG report finds enterprise disconnect between AI and its ROI | CIO
H
Hackread – Cybersecurity News, Data Breaches, AI and More
aimingoo的专栏
aimingoo的专栏

Proxmox Support Forum

[SOLVED] - Github Auth for Mirrors-Kernel Repo? [Automation] Mass migration tool for MS Win11/Server Proxmox GUI hang - not response is it possible to reject or quarantine spam based on conditions I set ? The PVENode task list in PVE9 is partially obscured due to the terminal font being too large. About 100% error reporting due to pveproxy.service hooks Kubernetes overlay networking breaks when upgrading from PVE 9.1 to PVE 9.2.3 Zentraler Speicher No space left on device Combine datastore and direct file archival to tape Kernel panic VFS: Unable to mount root fs on unknown-block (0,0) sobald ein 7.x Kernel verwendet wird. How to migrate disk of a VM from one ZFS to another Windows Server 2025 fails to boot after PVE 9.2 / Linux 7.0 Kernel upgrade Cannot Install Proxmox on T610 Poweredge with H700 PERC card sdn Config. gateway not reachable How to safely change domain/FQDN? Welche Filterquote erreicht ihr? NFS Share status unknown on 2 of 5 nodes Can't connect to PVE9 consoles [solved] Can't connect to PVE9 consoles [solved] [SOLVED] - Use secondary network for PVE commands Created cluster, one node storage gone BUG: proxmox mail gateway FROM = null bypass spam filtering Moving existing PBS from VMWare workstation to PVE cluster Does eBGP SDN fabric support external peering? Bug: PDM 1.1 not recognizing valid license status Proxmox GUI hang - not response PVE crashes unexpectedly Proxmox Backup Server 4.2 released! Advice ceph-osd crashes with kernel 6.17.2-1-pve on Dell system [META] Links on Proxmox Forum Website Hardwarer oder Software RAID Joining a cluster with already created guests VM PDM missing backup jobs from PVE / Log retention Remove VM.Monitor from all users/roles, PVE 9.2 Proxmox Freezing (new instalation) 9.2.2 - Intel 12700T No Web gui and random connection reset by peer [SOLVED] - i40e module for X710 Intel NIC Dutch Proxmox Day 2026 How pools use the space Corosync initiiert Reboot trotz Verfügbarkeit der Systeme Opt-in Linux 7.0 Kernel for Proxmox VE 9 available After PVE 8to9 upgrade, unable to check guest fs freeze status Problem with MegaRAID SAS3508 controller proxmox-kernel-7.0.2-6-pve failing network service Auto sync guest time after rollback of VM snapshot with RAM/state Broadcom BCM57504 (100G) bnxt_en TX timeout and NIC reset on Proxmox 8.1.5 — while BCM57414 (25G) works fine on same host QEMU 11.0 available on pve-test and pve-no-subscription as of now 350 MPM Solventless Lamination Machine for High-Speed Flexible Packaging Making sense of NVMe zfs and SMART errors [SOLVED] - PVE loses network connection after kernel upgrade to proxmox-kernel-7.0.0-3-pve [SOLVED] - Remove or reset cluster configuration. Proxmox 8.4.1 Fresh Install BCM57416 10G Ethernet Adapter Not Recognized PDM 1.1.1 unable to add AD realm with anonymous search [TUTORIAL] - Developer Workstation (Proxmox-VE 9) with cinnamon (LMDE7) SDN zone shows "pending" on peer nodes after node reboot (9.2.x) Cluster not quorate - extending auth key lifetime! Proxmox not rebooting properly (SOLVED) Proxmox 9 Stuck on loading initial ramdisk With new HA-Disarm Feature is there a Documentation for NUT Setup on Clusters? Proxmox 8.3 Installation Issue on ProLiant DL380 Gen9 Cluster networking setup LXC System images unavailable [SOLVED] - Fix: NVIDIA Drivers Failing after upgrade to Proxmox 9.2.2 (Kernel 7.0.2-6-pve) / NovaCore Conflict Install NUT directly on Proxmox VE and control guests from here driver usb for windows 7 System startup error and no network: Failed to start ifupdown2-pre.service - Helper to synchronize boot up for ifupdown. PBS backup space grow up constantly Proxmox Datacenter Manager 1.1 released! IPv4 not available in newly created VM Recommended Setup for Offsite Proxmox Backups? Hetzner Storage Box & Remote PBS Challenges duplicate, please delete this passthrought an USB device "by ID" to CT PDM Installer Freezes at 66% Tried PDM for the first time (version 1.1) - had issues PDM 1.1 automated install Suche Server-Provider für Proxmox connecting sdn to edge firewall SDN, IPAM & DHCP Migrating from read-only file system Ubuntu 26.04 installation fails for unknown reason Status Unbekannt nach Cluster Join Installing Proxmox Backup Server on Mac Mini (Late 2012) kernel 7.0 performance issue with zfs pools PVE becomes unreachable via ethernet but OS is running [SOLVED] - New 9.2 install - can't find 7.0.2-6-pve , not all the time [SOLVED] - Backup and dedupe a VM with LUKS Gibt es mit PVE 2.x ggf. Änderungen bei der RAM-Nutzung, bzw. deren Anzeige bei VMs? I need help for setting up backup solution Way more NAGware, very little functionality, bugs galore Root squashing virtiofsd with --uid-map Intel ixgbe Driver Update Fail Passkey Login (not 2FA) Roblox VM detection - can be overcome? [TUTORIAL] - ZFS-Autosnaptshot inkl. Rollback und Daten direkt recovern (Windows/Linux) How to stop PVE Kernel upgrade [SOLVED] - very long waiting to log in to lxc debian 11 ssh [TUTORIAL] - Configuring Fusion-Io (SanDisk) ioDrive, ioDrive2, ioScale and ioScale2 cards with Proxmox Increase maximum USB devices in vm.conf
bnx2x Network Card Driver stopped working (NetXtreme II BCM57810 10 Gigabit Ethernet NIC)
invalid@exam · 2026-06-16 · via Proxmox Support Forum

root@:~# ip link list
1: lo: <LOOPBACK,UP,LOWER_UP> mtu 65536 qdisc noqueue state UNKNOWN mode DEFAULT group default qlen 1000
link/loopback 00:00:00:00:00:00 brd 00:00:00:00:00:00
2: eno1: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc pfifo_fast master vmbr0 state UP mode DEFAULT group default qlen 1000
link/ether 84:69:93:85:64:fb brd ff:ff:ff:ff:ff:ff
altname enp0s31f6
3: ens1f1: <BROADCAST,MULTICAST> mtu 1500 qdisc noop master vmbr1 state DOWN mode DEFAULT group default qlen 1000
link/ether 8c:dc:d4:0f:98:34 brd ff:ff:ff:ff:ff:ff
altname enp1s0f1
4: ens1f0: <BROADCAST,MULTICAST> mtu 1500 qdisc noop master vmbr2 state DOWN mode DEFAULT group default qlen 1000
link/ether 8c:dc:d4:0f:98:30 brd ff:ff:ff:ff:ff:ff
altname enp1s0f0
5: vmbr0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc noqueue state UP mode DEFAULT group default qlen 1000
link/ether 84:69:93:85:64:fb brd ff:ff:ff:ff:ff:ff
6: vmbr1: <NO-CARRIER,BROADCAST,MULTICAST,UP> mtu 1500 qdisc noqueue state DOWN mode DEFAULT group default qlen 1000
link/ether 8c:dc:d4:0f:98:34 brd ff:ff:ff:ff:ff:ff
7: vmbr2: <NO-CARRIER,BROADCAST,MULTICAST,UP> mtu 1500 qdisc noqueue state DOWN mode DEFAULT group default qlen 1000
link/ether 8c:dc:d4:0f:98:30 brd ff:ff:ff:ff:ff:ff
8: tap113i0: <BROADCAST,MULTICAST,PROMISC,UP,LOWER_UP> mtu 1500 qdisc pfifo_fast master fwbr113i0 state UNKNOWN mode DEFAULT group default qlen 1000
link/ether 9a:8f:79:ed:d8:cf brd ff:ff:ff:ff:ff:ff
9: fwbr113i0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc noqueue state UP mode DEFAULT group default qlen 1000
link/ether 86:ab:c5:fe:84:b6 brd ff:ff:ff:ff:ff:ff
10: fwpr113p0@fwln113i0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc noqueue master vmbr0 state UP mode DEFAULT group default qlen 1000
link/ether e2:23:f6:d7:4a:02 brd ff:ff:ff:ff:ff:ff
11: fwln113i0@fwpr113p0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc noqueue master fwbr113i0 state UP mode DEFAULT group default qlen 1000
link/ether 86:ab:c5:fe:84:b6 brd ff:ff:ff:ff:ff:ff
12: tap114i0: <BROADCAST,MULTICAST,PROMISC,UP,LOWER_UP> mtu 1500 qdisc pfifo_fast master fwbr114i0 state UNKNOWN mode DEFAULT group default qlen 1000
link/ether 96:33:49:df:74:7e brd ff:ff:ff:ff:ff:ff
13: fwbr114i0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc noqueue state UP mode DEFAULT group default qlen 1000
link/ether 12:8a:1d:80:9b:ae brd ff:ff:ff:ff:ff:ff
14: fwpr114p0@fwln114i0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc noqueue master vmbr0 state UP mode DEFAULT group default qlen 1000
link/ether 12:83:21:95:f4:14 brd ff:ff:ff:ff:ff:ff
15: fwln114i0@fwpr114p0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc noqueue master fwbr114i0 state UP mode DEFAULT group default qlen 1000
link/ether 12:8a:1d:80:9b:ae brd ff:ff:ff:ff:ff:ff
16: tap115i0: <BROADCAST,MULTICAST,PROMISC,UP,LOWER_UP> mtu 1500 qdisc pfifo_fast master fwbr115i0 state UNKNOWN mode DEFAULT group default qlen 1000
link/ether 2a:ac:02:66:86:8f brd ff:ff:ff:ff:ff:ff
23: fwbr115i0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc noqueue state UP mode DEFAULT group default qlen 1000
link/ether 9e:83:7a:c5:6c:09 brd ff:ff:ff:ff:ff:ff
24: fwpr115p0@fwln115i0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc noqueue master vmbr0 state UP mode DEFAULT group default qlen 1000
link/ether 96:41:57:50:9c:8d brd ff:ff:ff:ff:ff:ff
25: fwln115i0@fwpr115p0: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc noqueue master fwbr115i0 state UP mode DEFAULT group default qlen 1000
link/ether 9e:83:7a:c5:6c:09 brd ff:ff:ff:ff:ff:ff
root@FLD-PMD801:~#