惯性聚合 高效追踪和阅读你感兴趣的博客、新闻、科技资讯
阅读原文 在惯性聚合中打开

推荐订阅源

Cyberwarzone
Cyberwarzone
Help Net Security
Help Net Security
L
LINUX DO - 最新话题
Security Archives - TechRepublic
Security Archives - TechRepublic
A
About on SuperTechFans
www.infosecurity-magazine.com
www.infosecurity-magazine.com
Attack and Defense Labs
Attack and Defense Labs
K
KPMG report finds enterprise disconnect between AI and its ROI | CIO
The GitHub Blog
The GitHub Blog
CTFtime.org: upcoming CTF events
CTFtime.org: upcoming CTF events
Webroot Blog
Webroot Blog
T
Tenable Blog
C
Cyber Attacks, Cyber Crime and Cyber Security
Microsoft Security Blog
Microsoft Security Blog
人人都是产品经理
人人都是产品经理
Simon Willison's Weblog
Simon Willison's Weblog
D
Docker
爱范儿
爱范儿
AI
AI
宝玉的分享
宝玉的分享
PCI Perspectives
PCI Perspectives
The Register - Security
The Register - Security
Project Zero
Project Zero
OSCHINA 社区最新新闻
OSCHINA 社区最新新闻
IT之家
IT之家
S
Securelist
Scott Helme
Scott Helme
B
Blog
Forbes - Security
Forbes - Security
Google DeepMind News
Google DeepMind News
T
The Blog of Author Tim Ferriss
月光博客
月光博客
P
Proofpoint News Feed
让小产品的独立变现更简单 - ezindie.com
让小产品的独立变现更简单 - ezindie.com
F
Fortinet All Blogs
H
Help Net Security
Last Week in AI
Last Week in AI
N
News and Events Feed by Topic
钛媒体:引领未来商业与生活新知
钛媒体:引领未来商业与生活新知
MyScale Blog
MyScale Blog
I
InfoQ
P
Privacy International News Feed
V
V2EX
有赞技术团队
有赞技术团队
G
Google Developers Blog
阮一峰的网络日志
阮一峰的网络日志
腾讯CDC
freeCodeCamp Programming Tutorials: Python, JavaScript, Git & More
S
Schneier on Security
T
Tailwind CSS Blog

Proxmox Support Forum

[SOLVED] - Github Auth for Mirrors-Kernel Repo? [Automation] Mass migration tool for MS Win11/Server Proxmox GUI hang - not response is it possible to reject or quarantine spam based on conditions I set ? The PVENode task list in PVE9 is partially obscured due to the terminal font being too large. About 100% error reporting due to pveproxy.service hooks Kubernetes overlay networking breaks when upgrading from PVE 9.1 to PVE 9.2.3 Zentraler Speicher No space left on device Combine datastore and direct file archival to tape Kernel panic VFS: Unable to mount root fs on unknown-block (0,0) sobald ein 7.x Kernel verwendet wird. How to migrate disk of a VM from one ZFS to another Windows Server 2025 fails to boot after PVE 9.2 / Linux 7.0 Kernel upgrade Cannot Install Proxmox on T610 Poweredge with H700 PERC card sdn Config. gateway not reachable How to safely change domain/FQDN? Welche Filterquote erreicht ihr? NFS Share status unknown on 2 of 5 nodes Can't connect to PVE9 consoles [solved] Can't connect to PVE9 consoles [solved] [SOLVED] - Use secondary network for PVE commands Created cluster, one node storage gone BUG: proxmox mail gateway FROM = null bypass spam filtering Moving existing PBS from VMWare workstation to PVE cluster Does eBGP SDN fabric support external peering? Bug: PDM 1.1 not recognizing valid license status Proxmox GUI hang - not response PVE crashes unexpectedly Proxmox Backup Server 4.2 released! Advice ceph-osd crashes with kernel 6.17.2-1-pve on Dell system [META] Links on Proxmox Forum Website Hardwarer oder Software RAID Joining a cluster with already created guests VM PDM missing backup jobs from PVE / Log retention Remove VM.Monitor from all users/roles, PVE 9.2 Proxmox Freezing (new instalation) 9.2.2 - Intel 12700T No Web gui and random connection reset by peer [SOLVED] - i40e module for X710 Intel NIC Dutch Proxmox Day 2026 How pools use the space Corosync initiiert Reboot trotz Verfügbarkeit der Systeme Opt-in Linux 7.0 Kernel for Proxmox VE 9 available After PVE 8to9 upgrade, unable to check guest fs freeze status Problem with MegaRAID SAS3508 controller proxmox-kernel-7.0.2-6-pve failing network service Auto sync guest time after rollback of VM snapshot with RAM/state Broadcom BCM57504 (100G) bnxt_en TX timeout and NIC reset on Proxmox 8.1.5 — while BCM57414 (25G) works fine on same host QEMU 11.0 available on pve-test and pve-no-subscription as of now 350 MPM Solventless Lamination Machine for High-Speed Flexible Packaging Making sense of NVMe zfs and SMART errors [SOLVED] - PVE loses network connection after kernel upgrade to proxmox-kernel-7.0.0-3-pve [SOLVED] - Remove or reset cluster configuration. Proxmox 8.4.1 Fresh Install BCM57416 10G Ethernet Adapter Not Recognized PDM 1.1.1 unable to add AD realm with anonymous search [TUTORIAL] - Developer Workstation (Proxmox-VE 9) with cinnamon (LMDE7) Cluster not quorate - extending auth key lifetime! Proxmox not rebooting properly (SOLVED) Proxmox 9 Stuck on loading initial ramdisk With new HA-Disarm Feature is there a Documentation for NUT Setup on Clusters? Proxmox 8.3 Installation Issue on ProLiant DL380 Gen9 Cluster networking setup LXC System images unavailable [SOLVED] - Fix: NVIDIA Drivers Failing after upgrade to Proxmox 9.2.2 (Kernel 7.0.2-6-pve) / NovaCore Conflict Install NUT directly on Proxmox VE and control guests from here driver usb for windows 7 System startup error and no network: Failed to start ifupdown2-pre.service - Helper to synchronize boot up for ifupdown. PBS backup space grow up constantly Proxmox Datacenter Manager 1.1 released! IPv4 not available in newly created VM Recommended Setup for Offsite Proxmox Backups? Hetzner Storage Box & Remote PBS Challenges duplicate, please delete this passthrought an USB device "by ID" to CT PDM Installer Freezes at 66% Tried PDM for the first time (version 1.1) - had issues PDM 1.1 automated install Suche Server-Provider für Proxmox connecting sdn to edge firewall SDN, IPAM & DHCP Migrating from read-only file system Ubuntu 26.04 installation fails for unknown reason Status Unbekannt nach Cluster Join Installing Proxmox Backup Server on Mac Mini (Late 2012) kernel 7.0 performance issue with zfs pools PVE becomes unreachable via ethernet but OS is running [SOLVED] - New 9.2 install - can't find 7.0.2-6-pve , not all the time [SOLVED] - Backup and dedupe a VM with LUKS Gibt es mit PVE 2.x ggf. Änderungen bei der RAM-Nutzung, bzw. deren Anzeige bei VMs? I need help for setting up backup solution Way more NAGware, very little functionality, bugs galore Root squashing virtiofsd with --uid-map Intel ixgbe Driver Update Fail Help to fix Proxmox access issues after power cut Passkey Login (not 2FA) Roblox VM detection - can be overcome? [TUTORIAL] - ZFS-Autosnaptshot inkl. Rollback und Daten direkt recovern (Windows/Linux) How to stop PVE Kernel upgrade [SOLVED] - very long waiting to log in to lxc debian 11 ssh [TUTORIAL] - Configuring Fusion-Io (SanDisk) ioDrive, ioDrive2, ioScale and ioScale2 cards with Proxmox Increase maximum USB devices in vm.conf
SDN zone shows "pending" on peer nodes after node reboot (9.2.x)
invalid@exam · 2026-05-29 · via Proxmox Support Forum

Hi everyone,

I found a SDN status issue in PVE 9.2.x. After a node reboot or temporary network outage, the recovered node increments its local SDN configuration version, leaving all other healthy nodes on the old version (flagged as pending).

Confirmed on: 9.2.2, 9.2.3 (`libpve-network-perl` 1.6.6)
Not observed on: 9.1.1 (`libpve-network-perl` 1.2.3)

Summary

After a node reboot or NIC-down event (HA fencing test), only the recovered node gets its
/etc/network/interfaces.d/sdn #version incremented. The other nodes are left on the
old version and are immediately flagged as pending

Running `Apply` from the GUI restores all nodes to available, but the issue reappears
on every subsequent reboot or NIC failure. **Reproducibility: 100%.**

There is no impact on VM connectivity — the issue is limited to the SDN status display.

Environment

| | 9.1.1 (not affected) | 9.2.3 (affected) |
|---|---|---|
| `pve-manager` | 9.1.1 | 9.2.3 |
| `libpve-network-perl` | **1.2.3** | **1.6.6** |
| Cluster | 3-node | 3-node |
| SDN zone types | Simple (OVS VLAN) + VXLAN | Simple (OVS VLAN) + VXLAN |

Steps to reproduce (9.2.x)

1. Apply SDN from GUI — confirm all nodes show `available`.
2. Reboot any one node (or bring down all NICs to trigger HA fence).
3. Wait for the node to rejoin the cluster.
4. Check SDN status — the recovered node shows `available`, all others show `pending`.

Before reboot / NIC-down (all nodes in sync)

Bash:

# head -1 /etc/network/interfaces.d/sdn
pve01: #version:58
pve02: #version:58
pve03: #version:58

After pve03 reboot / NIC-down (version increments only on the recovered node)

Bash:

# head -1 /etc/network/interfaces.d/sdn
pve01: #version:58
pve02: #version:58
pve03: #version:59  ← only the recovered node is incremented

Resulting SDN status

Code:

pve01: pending   (still on version:58 — judged as too old)
pve02: pending   (still on version:58 — judged as too old)
pve03: available (updated to version:59)

Questions

Is there a way to prevent the rejoining node from advancing its local SDN version?
Is there any workaround other than manually clicking "Apply" in the GUI after every reboot?

Hmm, seems like this is caused by the pve-sdn-commit one-shot service. Could you post your SDN configuration to see what seems to trigger this?

Code:

cat /etc/pve/sdn/zones.cfg
cat /etc/pve/sdn/vnets.cfg
cat /etc/pve/sdn/subnets.cfg

Thanks for your replay, Here is my SDN configuration:

Bash:

root@pve02:~# cat /etc/pve/sdn/zones.cfg
vlan: VMNet
        bridge vmbr0
        ipam pve

vlan: VMNet2
        bridge vmbr1
        ipam pve

vlan: Service
        bridge vmbr0
        ipam pve

root@pve02:~# cat /etc/pve/sdn/vnets.cfg
vnet: vNet1227
        zone Service
        tag 1227

vnet: vNet1214
        zone Service
        tag 1214

vnet: vNet1240
        zone Service
        tag 1240

root@pve02:~# cat /etc/pve/sdn/subnets.cfg
(empty)

How do the underlying bridges for the SDN zones look like?

Code:

cat /etc/network/interfaces

Here is my network configuration as well:

Bash:

root@pve02:~# cat /etc/network/interfaces
# network interface settings; autogenerated
# Please do NOT modify this file directly, unless you know what
# you're doing.
#
# If you want to manage parts of the network configuration manually,
# please utilize the 'source' or 'source-directory' directives to do
# so.
# PVE will preserve these directives, but will NOT read its network
# configuration from sourced files, so do not attempt to move any of
# the PVE managed interfaces into external files!

auto lo
iface lo inet loopback

auto nic0
iface nic0 inet manual

auto nic6
iface nic6 inet static
        address 192.168.0.52/24

iface nic7 inet manual

auto nic2
iface nic2 inet manual

auto nic3
iface nic3 inet manual

auto nic4
iface nic4 inet manual

auto nic5
iface nic5 inet manual

auto nic1
iface nic1 inet manual

auto mng_port0
iface mng_port0 inet static
        address 10.1.214.52/24
        gateway 10.1.214.1
        ovs_type OVSIntPort
        ovs_bridge vmbr0
        ovs_options tag=1214

auto bond0
iface bond0 inet manual
        ovs_bonds nic0 nic1
        ovs_type OVSBond
        ovs_bridge vmbr0
        ovs_options bond_mode=active-backup

auto bond1
iface bond1 inet manual
        bond-slaves nic4 nic5
        bond-miimon 100
        bond-mode active-backup
        bond-primary nic4

auto vmbr0
iface vmbr0 inet manual
        ovs_type OVSBridge
        ovs_ports bond0 mng_port0

auto vmbr1
iface vmbr1 inet static
        address 192.168.100.52/24
        bridge-ports bond1
        bridge-stp off
        bridge-fd 0

source /etc/network/interfaces.d/*
root@pve02:~#

We currently run the apply unconditionally if we detect a non-vlan-aware bridge, see [1] for more in-depth reasoning. We should maybe revisit if we can improve the situation there and improve the change detection.

In the meanwhile the problem should be avoidable by utilizing a vlan-aware bridge, which is recommended for bridges backing VLAN zones anyway.

You can simply set the bridges on each node to VLAN-aware, re-apply the network + SDN configuration, and then restart all VMs. If you don't want any service interruption then the procedure is a bit more tricky and needs to be done node by node instead:

  • migrate away all guests from the node you want to update
  • Set the underlying bridge (vmbr1) on the node to VLAN-aware
  • Apply the network configuration for that node
  • Apply the SDN configuration to re-generate the proper network configuration for that node
  • Migrate the guests back and check if everything worked as expected
  • repeat the procedure for every host in the cluster

[1] https://git.proxmox.com/?p=pve-manager.git;a=commit;h=ea09550b4feb79e033b7041f4156003d6507c6ae

Thank you for the explanation.

Just to confirm my understanding — if we are using an OVS Bridge, it cannot be set to VLAN-aware, so there is no way to avoid this issue in an OVS-based setup, correct?
Also, I tested setting only the Linux bridge (vmbr1) to VLAN-aware, but the pending issue still occurred.

I checked the code in pve-sdn-commit and IPRoute2.pm.

bridge_is_vlan_aware() only considers interfaces with linkinfo.info_kind == "bridge". Since OVS bridges use "openvswitch"instead, they appear to be treated as non-vlan-aware by the current implementation.

Since OVS ports are VLAN trunks by default, would it make sense to exclude OVS bridges from zone_uses_non_vlan_aware_bridge()?

I also tested a local patch that excludes OVS bridges from zone_uses_non_vlan_aware_bridge():

Code:

+    my $info_kind = $ip_link->{linkinfo}->{info_kind} // '';
+    return 0 if $info_kind eq 'openvswitch';

After applying the patch, I could no longer reproduce the pending state in my test environment.

I'll see if that doesn't trigger any edge cases with some OVS configurations and then update the detection accordingly!

Thank you for looking into this! I'm looking forward to the update.