惯性聚合 高效追踪和阅读你感兴趣的博客、新闻、科技资讯
阅读原文 在惯性聚合中打开

推荐订阅源

The Hacker News
The Hacker News
GbyAI
GbyAI
雷峰网
雷峰网
罗磊的独立博客
WordPress大学
WordPress大学
博客园_首页
Hugging Face - Blog
Hugging Face - Blog
The Cloudflare Blog
云风的 BLOG
云风的 BLOG
F
Full Disclosure
Google DeepMind News
Google DeepMind News
C
Cyber Attacks, Cyber Crime and Cyber Security
NISL@THU
NISL@THU
S
Schneier on Security
T
Tor Project blog
C
Cybersecurity and Infrastructure Security Agency CISA
Recent Announcements
Recent Announcements
酷 壳 – CoolShell
酷 壳 – CoolShell
C
Check Point Blog
P
Palo Alto Networks Blog
C
CERT Recently Published Vulnerability Notes
S
Secure Thoughts
Application and Cybersecurity Blog
Application and Cybersecurity Blog
Last Week in AI
Last Week in AI
T
Threatpost
I
Intezer
Y
Y Combinator Blog
G
GRAHAM CLULEY
MyScale Blog
MyScale Blog
阮一峰的网络日志
阮一峰的网络日志
T
The Exploit Database - CXSecurity.com
Scott Helme
Scott Helme
A
Arctic Wolf
Martin Fowler
Martin Fowler
Hacker News: Ask HN
Hacker News: Ask HN
V
V2EX
B
Blog RSS Feed
The Last Watchdog
The Last Watchdog
博客园 - 司徒正美
Simon Willison's Weblog
Simon Willison's Weblog
V
Vulnerabilities – Threatpost
OSCHINA 社区最新新闻
OSCHINA 社区最新新闻
N
News and Events Feed by Topic
www.infosecurity-magazine.com
www.infosecurity-magazine.com
让小产品的独立变现更简单 - ezindie.com
让小产品的独立变现更简单 - ezindie.com
P
Proofpoint News Feed
CTFtime.org: upcoming CTF events
CTFtime.org: upcoming CTF events
AI
AI
C
Cisco Blogs
T
The Blog of Author Tim Ferriss

Proxmox Support Forum

[SOLVED] - Github Auth for Mirrors-Kernel Repo? [Automation] Mass migration tool for MS Win11/Server Proxmox GUI hang - not response is it possible to reject or quarantine spam based on conditions I set ? The PVENode task list in PVE9 is partially obscured due to the terminal font being too large. About 100% error reporting due to pveproxy.service hooks Kubernetes overlay networking breaks when upgrading from PVE 9.1 to PVE 9.2.3 Zentraler Speicher No space left on device Combine datastore and direct file archival to tape Kernel panic VFS: Unable to mount root fs on unknown-block (0,0) sobald ein 7.x Kernel verwendet wird. How to migrate disk of a VM from one ZFS to another Windows Server 2025 fails to boot after PVE 9.2 / Linux 7.0 Kernel upgrade Cannot Install Proxmox on T610 Poweredge with H700 PERC card sdn Config. gateway not reachable How to safely change domain/FQDN? Welche Filterquote erreicht ihr? NFS Share status unknown on 2 of 5 nodes Can't connect to PVE9 consoles [solved] Can't connect to PVE9 consoles [solved] [SOLVED] - Use secondary network for PVE commands Created cluster, one node storage gone BUG: proxmox mail gateway FROM = null bypass spam filtering Moving existing PBS from VMWare workstation to PVE cluster Does eBGP SDN fabric support external peering? Bug: PDM 1.1 not recognizing valid license status Proxmox GUI hang - not response PVE crashes unexpectedly Proxmox Backup Server 4.2 released! Advice ceph-osd crashes with kernel 6.17.2-1-pve on Dell system [META] Links on Proxmox Forum Website Hardwarer oder Software RAID Joining a cluster with already created guests VM PDM missing backup jobs from PVE / Log retention Remove VM.Monitor from all users/roles, PVE 9.2 Proxmox Freezing (new instalation) 9.2.2 - Intel 12700T No Web gui and random connection reset by peer [SOLVED] - i40e module for X710 Intel NIC Dutch Proxmox Day 2026 How pools use the space Corosync initiiert Reboot trotz Verfügbarkeit der Systeme Opt-in Linux 7.0 Kernel for Proxmox VE 9 available After PVE 8to9 upgrade, unable to check guest fs freeze status Problem with MegaRAID SAS3508 controller proxmox-kernel-7.0.2-6-pve failing network service Auto sync guest time after rollback of VM snapshot with RAM/state Broadcom BCM57504 (100G) bnxt_en TX timeout and NIC reset on Proxmox 8.1.5 — while BCM57414 (25G) works fine on same host QEMU 11.0 available on pve-test and pve-no-subscription as of now 350 MPM Solventless Lamination Machine for High-Speed Flexible Packaging Making sense of NVMe zfs and SMART errors [SOLVED] - PVE loses network connection after kernel upgrade to proxmox-kernel-7.0.0-3-pve [SOLVED] - Remove or reset cluster configuration. Proxmox 8.4.1 Fresh Install BCM57416 10G Ethernet Adapter Not Recognized PDM 1.1.1 unable to add AD realm with anonymous search [TUTORIAL] - Developer Workstation (Proxmox-VE 9) with cinnamon (LMDE7) SDN zone shows "pending" on peer nodes after node reboot (9.2.x) Cluster not quorate - extending auth key lifetime! Proxmox not rebooting properly (SOLVED) Proxmox 9 Stuck on loading initial ramdisk With new HA-Disarm Feature is there a Documentation for NUT Setup on Clusters? Proxmox 8.3 Installation Issue on ProLiant DL380 Gen9 Cluster networking setup LXC System images unavailable [SOLVED] - Fix: NVIDIA Drivers Failing after upgrade to Proxmox 9.2.2 (Kernel 7.0.2-6-pve) / NovaCore Conflict Install NUT directly on Proxmox VE and control guests from here driver usb for windows 7 System startup error and no network: Failed to start ifupdown2-pre.service - Helper to synchronize boot up for ifupdown. PBS backup space grow up constantly Proxmox Datacenter Manager 1.1 released! IPv4 not available in newly created VM Recommended Setup for Offsite Proxmox Backups? Hetzner Storage Box & Remote PBS Challenges duplicate, please delete this passthrought an USB device "by ID" to CT PDM Installer Freezes at 66% Tried PDM for the first time (version 1.1) - had issues PDM 1.1 automated install Suche Server-Provider für Proxmox connecting sdn to edge firewall SDN, IPAM & DHCP Migrating from read-only file system Ubuntu 26.04 installation fails for unknown reason Status Unbekannt nach Cluster Join Installing Proxmox Backup Server on Mac Mini (Late 2012) kernel 7.0 performance issue with zfs pools PVE becomes unreachable via ethernet but OS is running [SOLVED] - New 9.2 install - can't find 7.0.2-6-pve , not all the time [SOLVED] - Backup and dedupe a VM with LUKS Gibt es mit PVE 2.x ggf. Änderungen bei der RAM-Nutzung, bzw. deren Anzeige bei VMs? I need help for setting up backup solution Way more NAGware, very little functionality, bugs galore Root squashing virtiofsd with --uid-map Intel ixgbe Driver Update Fail Passkey Login (not 2FA) Roblox VM detection - can be overcome? [TUTORIAL] - ZFS-Autosnaptshot inkl. Rollback und Daten direkt recovern (Windows/Linux) How to stop PVE Kernel upgrade [SOLVED] - very long waiting to log in to lxc debian 11 ssh [TUTORIAL] - Configuring Fusion-Io (SanDisk) ioDrive, ioDrive2, ioScale and ioScale2 cards with Proxmox Increase maximum USB devices in vm.conf
Persistent VM instability with Ryzen 9 9950X3D and Proxmox 8/9
invalid@exam · 2025-08-19 · via Proxmox Support Forum

Hi,

I’m running an ASUS ProArt X870E-Creator WiFi (BIOS 1605) with a Ryzen 9 9950X3D and 256 GB of RAM. My workflow requires spawning several VMs, but I’m seeing recurrent instability in guest VMs (both Windows and Linux): after a few hours they typically reboot or hang with what appear to be memory-related errors.

Hardware / memory tried

  • Crucial CP64G56C46U5 (64 GB modules), total 256 GB, currently running at 3600.
  • Corsair CMK192GX5M4B5200C38 (total 192 GB) — same behavior.
  • CPU swapped to Ryzen 9 9950Xsame behavior.

Firmware & settings

  • All firmware updated; motherboard BIOS is 1605.
  • 24 hours of memory testing reveal no erros.
  • Tried disabling Memory Context Restore and C-States; also tried leaving everything on Auto.
  • Issue reproduces on Proxmox VE 9 (and previously 8.4).

Despite these changes, the guest VMs remain unstable. The strange thing is that it's much worse with kernel 6.14 than it was with 6.8. With 6.8 these reboots happened after a few days, now with 6.14 are happening after a few hours.

Any ideas?

I have the same hardware, on CPU, chipset, and memory brand. What kept freezing me up, was any profile other than the default on my dimms - xmp or expo made my issues, even being well within published spec speed. Not sure if this is your problem as well.

I have left it all to the default setting in the bios. Have you any setting outside of the defaults (many are AUTO) in the BIOS? Do you use ZFS in any of your drives?

I have left it all to the default setting in the bios. Have you any setting outside of the defaults (many are AUTO) in the BIOS? Do you use ZFS in any of your drives?

Mostly all at auto with SVM enabled, and I don't have any ZFS drives. I also opted to use the x86-64-v4 cpu for my VMs, for what it's worth.

I now have a lead, if i run a stress test like AIDA64 in the VM, it doesn't reboot. If I stop, after a few hours, reboots. In the past I already switch off global C states, can it be something related?

Some boards actually have a dummy load to keep the "clever" power supplies from trying to go into auto power saving mode, when low loading occurs.

Look for "Power Loading" in your bios - it Enables or Disables dummy load. When the power supply is at low load, a self-protection will activate causing
it to shutdown or "fail", which when the bios is set to always power on after power loss, might look like a reboot. If this occurs, please set this option to Enabled.

Any news on this? Problem solved?

Also, any chance you could run:
cat /proc/iomem | grep -i 'PCI Bus'
on your system and share the output for me?

I’m trying to estimate how much MMIO space the ProArt X870E firmware reserves for PCIe devices. I’m looking for boards that allocate at least 1GB of MMIO address space, ideally more, to support dual GPU passthrough without hitting BAR assignment issues. Thanks!

Here you go, I have this motherboard with a 9950X3D

root@proxmox:~# cat /proc/iomem | grep -i 'PCI Bus'
000a0000-000dffff : PCI Bus 0000:00
70000000-dfffffff : PCI Bus 0000:00
70000000-710fffff : PCI Bus 0000:04
70000000-710fffff : PCI Bus 0000:05
70000000-700fffff : PCI Bus 0000:06
70100000-70efffff : PCI Bus 0000:07
70100000-70efffff : PCI Bus 0000:08
70100000-701fffff : PCI Bus 0000:09
70200000-707fffff : PCI Bus 0000:0c
70800000-70afffff : PCI Bus 0000:0a
70b00000-70cfffff : PCI Bus 0000:0b
70d00000-70dfffff : PCI Bus 0000:0e
70e00000-70efffff : PCI Bus 0000:0f
70f00000-70ffffff : PCI Bus 0000:10
71000000-710fffff : PCI Bus 0000:11
a4000000-d47fffff : PCI Bus 0000:12
a4000000-d47fffff : PCI Bus 0000:13
a4000000-bbffffff : PCI Bus 0000:18
bc000000-d3ffffff : PCI Bus 0000:48
d4000000-d43fffff : PCI Bus 0000:78
d4400000-d47fffff : PCI Bus 0000:79
d8000000-dc0fffff : PCI Bus 0000:01
dd800000-dddfffff : PCI Bus 0000:7a
dde00000-ddefffff : PCI Bus 0000:7b
ddf00000-ddffffff : PCI Bus 0000:03
de000000-de0fffff : PCI Bus 0000:02
1090000000-ffffffffff : PCI Bus 0000:00
1200000000-17ffffffff : PCI Bus 0000:01
b800000000-f7ffffffff : PCI Bus 0000:12
b800000000-f7ffffffff : PCI Bus 0000:13
b800000000-d7ffffffff : PCI Bus 0000:18
d800000000-f7ffffffff : PCI Bus 0000:48
fc10000000-fc1fffffff : PCI Bus 0000:7a

Wow. Fantastic! Thank you.

Not quite sure how to express how much that blows me away. The total MMIO space on the predecessor, the ProArt X670, wasn't even 1GB. Your ProArt X870 is offering up 100 times that amount! Promising indeed!

How has your experience been with Proxmox using this motherboard?

Not really, the latest test I did was with two 64Gb dimms instead of 4. Exactly the same issues. VMs, being it Linux or Windows, reboot after a few hours with memory erros when not in use. VLS=0, Global C states off, Typical Idle Power, No Dram power down, all the settings that could explain this. I'm running out of ideas, next steps will be system reinstall and after that PSU.

@billeman: can you share your setup information? Memory, settings, etc?

Thanks

Wow. Fantastic! Thank you.

Not quite sure how to express how much that blows me away. The total MMIO space on the predecessor, the ProArt X670, wasn't even 1GB. Your ProArt X870 is offering up 100 times that amount! Promising indeed!

How has your experience been with Proxmox using this motherboard?

Overall, I am very happy with this motherboard, but mostly have been running in on win11. I really really like the flexibility in the PCIE GEN5 bus (GPU GEN5 x8 + additional NVME GEN5 x4 and an free PCIE GEN5 x8 slot (running at x4).

Now typing this on a proxmox win11 VM with an RTX 5080 passed through, works great but for a proxmox n00b it's quite 'interesting' learning curve (but I have 30+ work experience).

Can't say I'm running it 24/7 though. too early. I've noticed that my VM locks up with "cpu : host" when running shadow of the tomb raider benchmark so I toned it down to x86-v3 and that work fine. It's pretty reproduceable. Works for me.

Cheers.

@billeman: can you share your setup information? Memory, settings, etc?

Thanks

Hi, I'm running 2 sticks of 32 GB of RAM from G.skill 6000 Mhz, running it with EXPO + 'Hynix 6000 mobo custom settings' , it's CL32 but I run it at CL30. So it's quite tight. I've been testing this on windows for several months and it's actually stable at 6200 with these settings but I usually go down a little to be sure.

I will never ever run 4 sticks again after the instability with my 5950x on AM4......

@EventHorizon
PSU problems are the worst. I had that once on a Windows 11 PC. I got bluescreens followed by a reboot at random intervals. Sometimes worked for days. Sometimes only hours. RAM was also my first suspicion, as there was nothing in the logs that was useful for diagnostic purposes. A pain in the rear. PSU is certainly a possible culprit.

I hope you get it sorted.

Last edited:

Hi, I'm running 2 sticks of 32 GB of RAM from G.skill 6000 Mhz, running it with EXPO + 'Hynix 6000 mobo custom settings' , it's CL32 but I run it at CL30. So it's quite tight. I've been testing this on windows for several months and it's actually stable at 6200 with these settings but I usually go down a little to be sure.

I will never ever run 4 sticks again after the instability with my 5950x on AM4......

Thanks, I'm running with 192Gb and 256Gb, and I cant seem to find clear reports of anyone with this size of rams, running it stable....

Thanks, I'm running with 192Gb and 256Gb, and I cant seem to find clear reports of anyone with this size of rams, running it stable....

Have you tried running with two sticks ?
What are your voltages for Memory, VSOC, VDDP etc ?
If your DIMMS support EXPO, try enabling it , but only while running two dimms.

Have you tried running with two sticks ?
What are your voltages for Memory, VSOC, VDDP etc ?
If your DIMMS support EXPO, try enabling it , but only while running two dimms.

Yep 2 dimms, also tried underclock to 3200, mem volt between 1.1 and 1.2, VSOC 1.25, etc.... There's something here fundamentally wrong and probably low level.

The question is if this is caused by proxmox (configuration) or not. I suppose you tested with a native OS on the same system ?

Try to run your RAM @3600 with the voltage the DOCP-Profile intends (1.25V?). A sign of memcontroller being rough at the edge is when your initial mem-training (after CMOS-Reset) takes over 15 minutes.
If that does not help, try 2 modules in productive usage 2-3 days...maybe to be safe initially @3600 and later you can also try DOCP-Profile. If that fails also, you can be 99% sure it's not the RAM.
Then try CPU ASPM off for 2-3 days, some PCIE-cards don't like that too aggressive. If that works, you can try L0-only.