惯性聚合 高效追踪和阅读你感兴趣的博客、新闻、科技资讯
阅读原文 在惯性聚合中打开

推荐订阅源

Martin Fowler
Martin Fowler
OSCHINA 社区最新新闻
OSCHINA 社区最新新闻
T
Troy Hunt's Blog
Latest news
Latest news
Vercel News
Vercel News
S
SegmentFault 最新的问题
V
Vulnerabilities – Threatpost
博客园 - Franky
P
Privacy International News Feed
A
Arctic Wolf
T
The Blog of Author Tim Ferriss
S
Schneier on Security
T
The Exploit Database - CXSecurity.com
P
Palo Alto Networks Blog
T
Tor Project blog
Jina AI
Jina AI
GbyAI
GbyAI
The Hacker News
The Hacker News
博客园 - 叶小钗
Google DeepMind News
Google DeepMind News
T
Threatpost
C
CERT Recently Published Vulnerability Notes
P
Proofpoint News Feed
Scott Helme
Scott Helme
WordPress大学
WordPress大学
www.infosecurity-magazine.com
www.infosecurity-magazine.com
Microsoft Azure Blog
Microsoft Azure Blog
CTFtime.org: upcoming CTF events
CTFtime.org: upcoming CTF events
博客园 - 司徒正美
A
About on SuperTechFans
Recorded Future
Recorded Future
爱范儿
爱范儿
L
LangChain Blog
V
V2EX
C
Cybersecurity and Infrastructure Security Agency CISA
The Cloudflare Blog
阮一峰的网络日志
阮一峰的网络日志
K
Kaspersky official blog
Webroot Blog
Webroot Blog
Security Archives - TechRepublic
Security Archives - TechRepublic
D
DataBreaches.Net
宝玉的分享
宝玉的分享
Google Online Security Blog
Google Online Security Blog
C
Cisco Blogs
L
Lohrmann on Cybersecurity
Help Net Security
Help Net Security
AWS News Blog
AWS News Blog
M
MIT News - Artificial intelligence
奇客Solidot–传递最新科技情报
奇客Solidot–传递最新科技情报
G
GRAHAM CLULEY

Proxmox Support Forum

[SOLVED] - Github Auth for Mirrors-Kernel Repo? [Automation] Mass migration tool for MS Win11/Server Proxmox GUI hang - not response is it possible to reject or quarantine spam based on conditions I set ? The PVENode task list in PVE9 is partially obscured due to the terminal font being too large. About 100% error reporting due to pveproxy.service hooks Kubernetes overlay networking breaks when upgrading from PVE 9.1 to PVE 9.2.3 Zentraler Speicher No space left on device Combine datastore and direct file archival to tape Kernel panic VFS: Unable to mount root fs on unknown-block (0,0) sobald ein 7.x Kernel verwendet wird. How to migrate disk of a VM from one ZFS to another Windows Server 2025 fails to boot after PVE 9.2 / Linux 7.0 Kernel upgrade Cannot Install Proxmox on T610 Poweredge with H700 PERC card sdn Config. gateway not reachable How to safely change domain/FQDN? Welche Filterquote erreicht ihr? NFS Share status unknown on 2 of 5 nodes Can't connect to PVE9 consoles [solved] Can't connect to PVE9 consoles [solved] [SOLVED] - Use secondary network for PVE commands Created cluster, one node storage gone BUG: proxmox mail gateway FROM = null bypass spam filtering Moving existing PBS from VMWare workstation to PVE cluster Does eBGP SDN fabric support external peering? Bug: PDM 1.1 not recognizing valid license status Proxmox GUI hang - not response PVE crashes unexpectedly Proxmox Backup Server 4.2 released! Advice ceph-osd crashes with kernel 6.17.2-1-pve on Dell system [META] Links on Proxmox Forum Website Hardwarer oder Software RAID Joining a cluster with already created guests VM PDM missing backup jobs from PVE / Log retention Remove VM.Monitor from all users/roles, PVE 9.2 Proxmox Freezing (new instalation) 9.2.2 - Intel 12700T No Web gui and random connection reset by peer [SOLVED] - i40e module for X710 Intel NIC Dutch Proxmox Day 2026 How pools use the space Corosync initiiert Reboot trotz Verfügbarkeit der Systeme Opt-in Linux 7.0 Kernel for Proxmox VE 9 available After PVE 8to9 upgrade, unable to check guest fs freeze status Problem with MegaRAID SAS3508 controller proxmox-kernel-7.0.2-6-pve failing network service Auto sync guest time after rollback of VM snapshot with RAM/state Broadcom BCM57504 (100G) bnxt_en TX timeout and NIC reset on Proxmox 8.1.5 — while BCM57414 (25G) works fine on same host QEMU 11.0 available on pve-test and pve-no-subscription as of now 350 MPM Solventless Lamination Machine for High-Speed Flexible Packaging Making sense of NVMe zfs and SMART errors [SOLVED] - PVE loses network connection after kernel upgrade to proxmox-kernel-7.0.0-3-pve [SOLVED] - Remove or reset cluster configuration. Proxmox 8.4.1 Fresh Install BCM57416 10G Ethernet Adapter Not Recognized PDM 1.1.1 unable to add AD realm with anonymous search [TUTORIAL] - Developer Workstation (Proxmox-VE 9) with cinnamon (LMDE7) SDN zone shows "pending" on peer nodes after node reboot (9.2.x) Cluster not quorate - extending auth key lifetime! Proxmox not rebooting properly (SOLVED) Proxmox 9 Stuck on loading initial ramdisk With new HA-Disarm Feature is there a Documentation for NUT Setup on Clusters? Proxmox 8.3 Installation Issue on ProLiant DL380 Gen9 Cluster networking setup LXC System images unavailable [SOLVED] - Fix: NVIDIA Drivers Failing after upgrade to Proxmox 9.2.2 (Kernel 7.0.2-6-pve) / NovaCore Conflict Install NUT directly on Proxmox VE and control guests from here driver usb for windows 7 System startup error and no network: Failed to start ifupdown2-pre.service - Helper to synchronize boot up for ifupdown. PBS backup space grow up constantly Proxmox Datacenter Manager 1.1 released! IPv4 not available in newly created VM Recommended Setup for Offsite Proxmox Backups? Hetzner Storage Box & Remote PBS Challenges duplicate, please delete this passthrought an USB device "by ID" to CT PDM Installer Freezes at 66% Tried PDM for the first time (version 1.1) - had issues PDM 1.1 automated install Suche Server-Provider für Proxmox connecting sdn to edge firewall SDN, IPAM & DHCP Migrating from read-only file system Ubuntu 26.04 installation fails for unknown reason Status Unbekannt nach Cluster Join Installing Proxmox Backup Server on Mac Mini (Late 2012) kernel 7.0 performance issue with zfs pools PVE becomes unreachable via ethernet but OS is running [SOLVED] - New 9.2 install - can't find 7.0.2-6-pve , not all the time [SOLVED] - Backup and dedupe a VM with LUKS Gibt es mit PVE 2.x ggf. Änderungen bei der RAM-Nutzung, bzw. deren Anzeige bei VMs? I need help for setting up backup solution Way more NAGware, very little functionality, bugs galore Root squashing virtiofsd with --uid-map Intel ixgbe Driver Update Fail Passkey Login (not 2FA) Roblox VM detection - can be overcome? [TUTORIAL] - ZFS-Autosnaptshot inkl. Rollback und Daten direkt recovern (Windows/Linux) How to stop PVE Kernel upgrade [SOLVED] - very long waiting to log in to lxc debian 11 ssh [TUTORIAL] - Configuring Fusion-Io (SanDisk) ioDrive, ioDrive2, ioScale and ioScale2 cards with Proxmox Increase maximum USB devices in vm.conf
Wie verhält sich ein Proxmox Host als NUT Client wenn eine VM der NUT Server ist?
invalid@exam · 2026-06-08 · via Proxmox Support Forum

Moin ThoSo

Danke für Deine Überlegungen/Hinweise. Ich habe festgestellt das ich mich wohl doch noch mal intensiver mit dem Thema NUT beschäftigen muss. :D In den letzten Jahren habe ich es mir da ziemlich einfach gemacht: Einfach ein Synology NAS als NUT Server genutzt, dort dann die Clients eingetragen

DS_NUT.png
und bei den Clients dann einfach NUT als NUT Client einrichtet und aktiviert. Also im Prinzip nur MODE=netclient und fertig. Bei dem Proxmox Host sieht das dann halt so aus:

Code:

root@pve:~# upsc ups@192.168.1.165
Init SSL without certificate database
battery.charge: 99
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 1511
battery.type: PbAcid
battery.voltage: 13.5
battery.voltage.nominal: 12
device.mfr: CPS
device.model: BR700ELCD
device.type: ups
driver.name: usbhid-ups
driver.parameter.pollfreq: 30
driver.parameter.pollinterval: 5
driver.parameter.port: auto
driver.parameter.synchronous: no
driver.version: DSM7-3-new-86004-251107
driver.version.data: CyberPower HID 0.4
driver.version.internal: 0.41
input.voltage: 231.0
input.voltage.nominal: 230
output.voltage: 230.0
ups.beeper.status: enabled
ups.delay.shutdown: 20
ups.delay.start: 30
ups.load: 25
ups.mfr: CPS
ups.model: BR700ELCD
ups.productid: 0501
ups.realpower.nominal: 420
ups.status: OL CHRG
ups.test.result: No test initiated
ups.timer.shutdown: -60

Was dann genau wie bei den Clients passiert und was ich da dann ggf. noch individuell einstellen könnte oder sogar müsste, war irgendwie noch nie so wirklich ein Thema für mich. Also eher nach dem Motto: Der NUT-Server auf dem Synology NAS wird die NUT Clients dann schon entsprechend steuern. :D

dann könnte der NUT Server nicht mehr sagen können "Kommando zurück - alles wieder grün".

Kann er das überhaupt sagen? In meinem Beispiel mit dem NUT Server auf dem Synology NAS habe ich über die NUT Server Funktion ja nicht wirklich Einstellmöglichkeiten was dann wie und wann bei den NUT Clients passiert. Hm .... wie gesagt muss ich mich doch noch mal intensiver mit dem Thema befassen und eben auch speziell in Bezug zu Proxmox und den darauf dann laufenden Dingen. Auch z.B. das Thema mit einer laufenden Home Assistant VM unter Proxmox, bei der aktuell ja auch der NUT Client eingerichtet ist.

HA_NUT_Client.png

Hier stellt sich für mich z.B. die Frage was für einen Sinn das ggf. macht, wenn der Proxmox Host ja auch schon als NUT Client eingerichtet ist und somit dann auch das Verhalten der VMs steuert. D.h. in diesem Fall würde der Proxmox Host ja von dem NUT Server Befehle erhalten und die HA VM auch noch.

Wie sich das Synology NAS verhält ist ja klar beschrieben:

Wenn Synology NAS den Standby-Modus aufruft, werden sämtliche Dienste gestoppt und Volumes entfernt, um einen Datenverlust zu verhindern und das Gerät sicher heruntergefahren, wenn das USV-Gerät keinen Strom mehr hat. Das System wechselt standardmäßig in den Standby-Modus, wenn das USV-Gerät nur noch wenig Strom hat. Sie können auch die Zeit angeben, bis Synology NAS im Falle eines Stromausfalls in den Standby-Modus wechselt. Wenn das USV-Gerät allerdings bereits vor der angegebenen Zeit nur noch wenig Strom hat, wechselt das System sofort in den Standby-Modus.
In Situationen, in denen das Synology NAS im Standby-Modus herunterfährt, wird das Gerät automatisch eingeschaltet, wenn die Stromversorgung wiederhergestellt ist, falls die Option Nach Stromausfall automatisch neu starten aktiviert ist (unter Systemsteuerung > Hardware & Energie > Allgemein).

Aber genau solche Infos fehlen mir halt noch in Verbindung mit Proxmox und den dann darauf laufenden Dingen wie z.B. der Home Assistant VM.

Mein primäres Ziel ist es ja eigentlich das die USV kurze Stromausfälle von z.B. 5 Minuten oder so überbrückt und bei längeren Stromausfällen halt alle NUT Clients, incl. all der Dinge die darauf laufen (bei Proxmox halt die VM/LXCs), sauber herunterfährt. In der NUT Doku https://networkupstools.org/documentation.html oder z.B. auch in dem immer mal wieder erwähnten Artikel zu dem Thema Proxmox + NUT https://www.kreaweb.be/diy-home-server-2021-software-proxmox-ups/ wird natürlich so gut wie alles beschrieben und dann eben auch anhand von Befehlszeilen dargestellt, aber mir pers. fehlen dann immer irgendwie die Zusammenhänge, also hier in dem Beispiel mit Proxmox als NUT Client und einer darauf laufenden VM bei der auch ein NUT Client aktiv ist. Also braucht es das überhaupt, oder wäre das "doppelt gemoppelt" und was passiert dann wo, wann und wie. :D

VG Jim