惯性聚合 高效追踪和阅读你感兴趣的博客、新闻、科技资讯
阅读原文 在惯性聚合中打开

推荐订阅源

WordPress大学
WordPress大学
T
The Blog of Author Tim Ferriss
V
V2EX
T
Tailwind CSS Blog
N
News | PayPal Newsroom
The Cloudflare Blog
Martin Fowler
Martin Fowler
大猫的无限游戏
大猫的无限游戏
C
Cyber Attacks, Cyber Crime and Cyber Security
OSCHINA 社区最新新闻
OSCHINA 社区最新新闻
I
InfoQ
V
Vulnerabilities – Threatpost
Apple Machine Learning Research
Apple Machine Learning Research
Threat Intelligence Blog | Flashpoint
Threat Intelligence Blog | Flashpoint
酷 壳 – CoolShell
酷 壳 – CoolShell
freeCodeCamp Programming Tutorials: Python, JavaScript, Git & More
T
Threat Research - Cisco Blogs
云风的 BLOG
云风的 BLOG
阮一峰的网络日志
阮一峰的网络日志
T
Threatpost
U
Unit 42
T
The Exploit Database - CXSecurity.com
I
Intezer
爱范儿
爱范儿
CTFtime.org: upcoming CTF events
CTFtime.org: upcoming CTF events
博客园 - Franky
Spread Privacy
Spread Privacy
A
Arctic Wolf
Microsoft Azure Blog
Microsoft Azure Blog
罗磊的独立博客
cs.CL updates on arXiv.org
cs.CL updates on arXiv.org
H
Hackread – Cybersecurity News, Data Breaches, AI and More
N
News and Events Feed by Topic
Google Online Security Blog
Google Online Security Blog
Hacker News - Newest:
Hacker News - Newest: "LLM"
Recorded Future
Recorded Future
The Register - Security
The Register - Security
Y
Y Combinator Blog
M
MIT News - Artificial intelligence
H
Help Net Security
Schneier on Security
Schneier on Security
P
Proofpoint News Feed
W
WeLiveSecurity
The Last Watchdog
The Last Watchdog
K
Kaspersky official blog
C
Check Point Blog
小众软件
小众软件
A
About on SuperTechFans
博客园 - 【当耐特】
IT之家
IT之家

Proxmox Support Forum

[SOLVED] - Github Auth for Mirrors-Kernel Repo? [Automation] Mass migration tool for MS Win11/Server Proxmox GUI hang - not response is it possible to reject or quarantine spam based on conditions I set ? The PVENode task list in PVE9 is partially obscured due to the terminal font being too large. About 100% error reporting due to pveproxy.service hooks Kubernetes overlay networking breaks when upgrading from PVE 9.1 to PVE 9.2.3 Zentraler Speicher No space left on device Combine datastore and direct file archival to tape Kernel panic VFS: Unable to mount root fs on unknown-block (0,0) sobald ein 7.x Kernel verwendet wird. How to migrate disk of a VM from one ZFS to another Windows Server 2025 fails to boot after PVE 9.2 / Linux 7.0 Kernel upgrade Cannot Install Proxmox on T610 Poweredge with H700 PERC card sdn Config. gateway not reachable How to safely change domain/FQDN? Welche Filterquote erreicht ihr? NFS Share status unknown on 2 of 5 nodes Can't connect to PVE9 consoles [solved] Can't connect to PVE9 consoles [solved] [SOLVED] - Use secondary network for PVE commands Created cluster, one node storage gone BUG: proxmox mail gateway FROM = null bypass spam filtering Moving existing PBS from VMWare workstation to PVE cluster Does eBGP SDN fabric support external peering? Bug: PDM 1.1 not recognizing valid license status Proxmox GUI hang - not response PVE crashes unexpectedly Proxmox Backup Server 4.2 released! Advice ceph-osd crashes with kernel 6.17.2-1-pve on Dell system [META] Links on Proxmox Forum Website Hardwarer oder Software RAID Joining a cluster with already created guests VM PDM missing backup jobs from PVE / Log retention Remove VM.Monitor from all users/roles, PVE 9.2 Proxmox Freezing (new instalation) 9.2.2 - Intel 12700T No Web gui and random connection reset by peer [SOLVED] - i40e module for X710 Intel NIC Dutch Proxmox Day 2026 How pools use the space Corosync initiiert Reboot trotz Verfügbarkeit der Systeme Opt-in Linux 7.0 Kernel for Proxmox VE 9 available After PVE 8to9 upgrade, unable to check guest fs freeze status Problem with MegaRAID SAS3508 controller proxmox-kernel-7.0.2-6-pve failing network service Auto sync guest time after rollback of VM snapshot with RAM/state Broadcom BCM57504 (100G) bnxt_en TX timeout and NIC reset on Proxmox 8.1.5 — while BCM57414 (25G) works fine on same host QEMU 11.0 available on pve-test and pve-no-subscription as of now 350 MPM Solventless Lamination Machine for High-Speed Flexible Packaging Making sense of NVMe zfs and SMART errors [SOLVED] - PVE loses network connection after kernel upgrade to proxmox-kernel-7.0.0-3-pve [SOLVED] - Remove or reset cluster configuration. Proxmox 8.4.1 Fresh Install BCM57416 10G Ethernet Adapter Not Recognized PDM 1.1.1 unable to add AD realm with anonymous search [TUTORIAL] - Developer Workstation (Proxmox-VE 9) with cinnamon (LMDE7) SDN zone shows "pending" on peer nodes after node reboot (9.2.x) Cluster not quorate - extending auth key lifetime! Proxmox not rebooting properly (SOLVED) Proxmox 9 Stuck on loading initial ramdisk With new HA-Disarm Feature is there a Documentation for NUT Setup on Clusters? Proxmox 8.3 Installation Issue on ProLiant DL380 Gen9 Cluster networking setup LXC System images unavailable [SOLVED] - Fix: NVIDIA Drivers Failing after upgrade to Proxmox 9.2.2 (Kernel 7.0.2-6-pve) / NovaCore Conflict Install NUT directly on Proxmox VE and control guests from here driver usb for windows 7 System startup error and no network: Failed to start ifupdown2-pre.service - Helper to synchronize boot up for ifupdown. PBS backup space grow up constantly Proxmox Datacenter Manager 1.1 released! IPv4 not available in newly created VM Recommended Setup for Offsite Proxmox Backups? Hetzner Storage Box & Remote PBS Challenges duplicate, please delete this passthrought an USB device "by ID" to CT PDM Installer Freezes at 66% Tried PDM for the first time (version 1.1) - had issues PDM 1.1 automated install Suche Server-Provider für Proxmox connecting sdn to edge firewall SDN, IPAM & DHCP Migrating from read-only file system Ubuntu 26.04 installation fails for unknown reason Status Unbekannt nach Cluster Join Installing Proxmox Backup Server on Mac Mini (Late 2012) kernel 7.0 performance issue with zfs pools PVE becomes unreachable via ethernet but OS is running [SOLVED] - New 9.2 install - can't find 7.0.2-6-pve , not all the time [SOLVED] - Backup and dedupe a VM with LUKS Gibt es mit PVE 2.x ggf. Änderungen bei der RAM-Nutzung, bzw. deren Anzeige bei VMs? I need help for setting up backup solution Way more NAGware, very little functionality, bugs galore Root squashing virtiofsd with --uid-map Intel ixgbe Driver Update Fail Passkey Login (not 2FA) Roblox VM detection - can be overcome? [TUTORIAL] - ZFS-Autosnaptshot inkl. Rollback und Daten direkt recovern (Windows/Linux) How to stop PVE Kernel upgrade [SOLVED] - very long waiting to log in to lxc debian 11 ssh [TUTORIAL] - Configuring Fusion-Io (SanDisk) ioDrive, ioDrive2, ioScale and ioScale2 cards with Proxmox Increase maximum USB devices in vm.conf
[SOLVED] - Upgrading from PVE 8 to 9 - One node successful, one node failed
invalid@exam · 2026-06-02 · via Proxmox Support Forum

I was trying upgrade both nodes of my 8.4 PVEs to 9.x. One completed successfully, but one failed. I can't figure out how to resolve this particular one. Can someone point me in the correct direction?

root@pve1:~# sudo apt install -f
Reading package lists... Done
Building dependency tree... Done
Reading state information... Done
0 upgraded, 0 newly installed, 0 to remove and 78 not upgraded.
5 not fully installed or removed.
After this operation, 0 B of additional disk space will be used.
Setting up proxmox-kernel-6.8.12-29-pve-signed (6.8.12-29) ...
Examining /etc/kernel/postinst.d.
run-parts: executing /etc/kernel/postinst.d/dkms 6.8.12-29-pve /boot/vmlinuz-6.8.12-29-pve
dkms: running auto installation service for kernel 6.8.12-29-pve.
Sign command: /lib/modules/6.8.12-29-pve/build/scripts/sign-file
Signing key: /var/lib/dkms/mok.key
Public certificate (MOK): /var/lib/dkms/mok.pub
Error! The /var/lib/dkms/i915-sriov-dkms/6.5.13-3/6.8.12-29-pve/x86_64/dkms.conf for module i915-sriov-dkms includes a BUILD_EXCLUSIVE directive which does not match this kernel/arch/config.
This indicates that it should not be built.
Error! One or more modules failed to install during autoinstall.
Refer to previous errors for more information.
dkms: autoinstall for kernel: 6.8.12-29-pve

failed!

run-parts: /etc/kernel/postinst.d/dkms exited with return code 11
Failed to process /etc/kernel/postinst.d at /var/lib/dpkg/info/proxmox-kernel-6.8.12-29-pve-signed.postinst line 20.
dpkg: error processing package proxmox-kernel-6.8.12-29-pve-signed (--configure):
installed proxmox-kernel-6.8.12-29-pve-signed package post-installation script subprocess returned error exit status 2

Setting up proxmox-kernel-7.0.6-2-pve-signed (7.0.6-2) ...
Examining /etc/kernel/postinst.d.
run-parts: executing /etc/kernel/postinst.d/dkms 7.0.6-2-pve /boot/vmlinuz-7.0.6-2-pve
dkms: running auto installation service for kernel 7.0.6-2-pve.
Sign command: /lib/modules/7.0.6-2-pve/build/scripts/sign-file
Signing key: /var/lib/dkms/mok.key
Public certificate (MOK): /var/lib/dkms/mok.pub
Error! The /var/lib/dkms/i915-sriov-dkms/6.5.13-3/7.0.6-2-pve/x86_64/dkms.conf for module i915-sriov-dkms includes a BUILD_EXCLUSIVE directive which does not match this kernel/arch/config.
This indicates that it should not be built.
Error! One or more modules failed to install during autoinstall.
Refer to previous errors for more information.
dkms: autoinstall for kernel: 7.0.6-2-pve failed!
run-parts: /etc/kernel/postinst.d/dkms exited with return code 11
Failed to process /etc/kernel/postinst.d at /var/lib/dpkg/info/proxmox-kernel-7.0.6-2-pve-signed.postinst line 20.
dpkg: error processing package proxmox-kernel-7.0.6-2-pve-signed (--configure):
installed proxmox-kernel-7.0.6-2-pve-signed package post-installation script subprocess returned error exit status 2

dpkg: dependency problems prevent configuration of proxmox-kernel-6.8:
proxmox-kernel-6.8 depends on proxmox-kernel-6.8.12-29-pve-signed | proxmox-kernel-6.8.12-29-pve; however:
Package proxmox-kernel-6.8.12-29-pve-signed is not configured yet.
Package proxmox-kernel-6.8.12-29-pve is not installed.
Package proxmox-kernel-6.8.12-29-pve-signed which provides proxmox-kernel-6.8.12-29-pve is not configured yet.

dpkg: error processing package proxmox-kernel-6.8 (--configure):
dependency problems - leaving unconfigured
dpkg: dependency problems prevent configuration of proxmox-kernel-7.0:
proxmox-kernel-7.0 depends on proxmox-kernel-7.0.6-2-pve-signed | proxmox-kernel-7.0.6-2-pve; however:
Package proxmox-kernel-7.0.6-2-pve-signed is not configured yet.
Package proxmox-kernel-7.0.6-2-pve is not installed.
Package proxmox-kernel-7.0.6-2-pve-signed which provides proxmox-kernel-7.0.6-2-pve is not configured yet.

dpkg: error processing package proxmox-kernel-7.0 (--configure):
dependency problems - leaving unconfigured
dpkg: dependency problems prevent configuration of proxmox-default-kernel:
proxmox-default-kernel depends on proxmox-kernel-7.0; however:
Package proxmox-kernel-7.0 is not configured yet.

dpkg: error processing package proxmox-default-kernel (--configure):
dependency problems - leaving unconfigured
Errors were encountered while processing:
proxmox-kernel-6.8.12-29-pve-signed
proxmox-kernel-7.0.6-2-pve-signed
proxmox-kernel-6.8
proxmox-kernel-7.0
proxmox-default-kernel
Removing subscription nag from UI...
E: Sub-process /usr/bin/dpkg returned an error code (1)
root@pve1:~# nano /var/lib/dkms/i915-sriov-dkms/6.5.13-3/7.0.6-2-pve/x86_64/dkms.conf
root@pve1:~# nano /var/lib/dkms/i915-sriov-dkms/6.5.13-3/7.0.6-2-pve/x86_64/dkms.conf
root@pve1:~# cd /var/lib/dkms/i915-sriov-dkms/6.5.13-3/7.0.6-2-pve/x86_64/dkms.conf
-bash: cd: /var/lib/dkms/i915-sriov-dkms/6.5.13-3/7.0.6-2-pve/x86_64/dkms.conf: No such file or directory
root@pve1:~# cd /var/lib/dkms/i915-sriov-dkms/6.5.13-3/7.0.6-2-pve/x86_64
-bash: cd: /var/lib/dkms/i915-sriov-dkms/6.5.13-3/7.0.6-2-pve/x86_64: No such file or directory
root@pve1:~#

Error! The /var/lib/dkms/i915-sriov-dkms/6.5.13-3/7.0.6-2-pve/x86_64/dkms.conf for module i915-sriov-dkms includes a BUILD_EXCLUSIVE directive which does not match this kernel/arch/config.
You probably need to get a newer driver version (from wherever you manually got this) that is compatible with the new Linux kernel.

EDIT: Lots of threads on this forum about third-party drivers (mostly NVidia but also AMD and others) that happen to be incompatible with newer Linux kernels as the Linux kernel does not provide a stable interface. Maybe consider switching to a (open-source) driver that comes with the Linux kernel? Or maybe the maintainers of that driver can upstream it to the kernel?

Last edited:

Error! The /var/lib/dkms/i915-sriov-dkms/6.5.13-3/7.0.6-2-pve/x86_64/dkms.conf for module i915-sriov-dkms includes a BUILD_EXCLUSIVE directive which does not match this kernel/arch/config.
You probably need to get a newer driver version (from wherever you manually got this) that is compatible with the new Linux kernel.

EDIT: Lots of threads on this forum about third-party drivers (mostly NVidia but also AMD and others) that happen to be incompatible with newer Linux kernels as the Linux kernel does not provide a stable interface. Maybe consider switching to a (open-source) driver that comes with the Linux kernel? Or maybe the maintainers of that driver can upstream it to the kernel?

Thanks for the suggestion. I'll see if I can either update or remove that driver.

That was it. I removed the drivers and it completed the update. Running on 9.2.3 now. Thank you very much!

I removed the drivers and it completed the update.

Sure, but what functionality are you missing? There must have been a reason for you to download and install a third-party driver. If the driver or functionality has been integrated into Linux then that's the best outcome of course. Just wondering..