惯性聚合 高效追踪和阅读你感兴趣的博客、新闻、科技资讯
阅读原文 在惯性聚合中打开

推荐订阅源

V
Vulnerabilities – Threatpost
Hacker News: Ask HN
Hacker News: Ask HN
S
Schneier on Security
G
GRAHAM CLULEY
AWS News Blog
AWS News Blog
C
CERT Recently Published Vulnerability Notes
T
The Exploit Database - CXSecurity.com
P
Privacy International News Feed
Cyberwarzone
Cyberwarzone
Spread Privacy
Spread Privacy
cs.CL updates on arXiv.org
cs.CL updates on arXiv.org
T
Tor Project blog
月光博客
月光博客
M
MIT News - Artificial intelligence
Stack Overflow Blog
Stack Overflow Blog
E
Exploit-DB.com RSS Feed
V
V2EX
量子位
Apple Machine Learning Research
Apple Machine Learning Research
J
Java Code Geeks
C
Cisco Blogs
G
Google Developers Blog
GbyAI
GbyAI
C
Check Point Blog
云风的 BLOG
云风的 BLOG
Cisco Talos Blog
Cisco Talos Blog
Jina AI
Jina AI
P
Palo Alto Networks Blog
Cloudbric
Cloudbric
N
Netflix TechBlog - Medium
酷 壳 – CoolShell
酷 壳 – CoolShell
C
Cybersecurity and Infrastructure Security Agency CISA
S
Secure Thoughts
雷峰网
雷峰网
博客园 - 三生石上(FineUI控件)
P
Privacy & Cybersecurity Law Blog
O
OpenAI News
CTFtime.org: upcoming CTF events
CTFtime.org: upcoming CTF events
有赞技术团队
有赞技术团队
I
Intezer
Blog — PlanetScale
Blog — PlanetScale
Cyber Security Advisories - MS-ISAC
Cyber Security Advisories - MS-ISAC
Schneier on Security
Schneier on Security
Microsoft Security Blog
Microsoft Security Blog
D
DataBreaches.Net
Help Net Security
Help Net Security
S
Security Archives - TechRepublic
K
KPMG report finds enterprise disconnect between AI and its ROI | CIO
H
Hackread – Cybersecurity News, Data Breaches, AI and More
aimingoo的专栏
aimingoo的专栏

Proxmox Support Forum

[SOLVED] - Github Auth for Mirrors-Kernel Repo? [Automation] Mass migration tool for MS Win11/Server Proxmox GUI hang - not response is it possible to reject or quarantine spam based on conditions I set ? The PVENode task list in PVE9 is partially obscured due to the terminal font being too large. About 100% error reporting due to pveproxy.service hooks Kubernetes overlay networking breaks when upgrading from PVE 9.1 to PVE 9.2.3 Zentraler Speicher No space left on device Combine datastore and direct file archival to tape Kernel panic VFS: Unable to mount root fs on unknown-block (0,0) sobald ein 7.x Kernel verwendet wird. How to migrate disk of a VM from one ZFS to another Windows Server 2025 fails to boot after PVE 9.2 / Linux 7.0 Kernel upgrade Cannot Install Proxmox on T610 Poweredge with H700 PERC card sdn Config. gateway not reachable How to safely change domain/FQDN? Welche Filterquote erreicht ihr? NFS Share status unknown on 2 of 5 nodes Can't connect to PVE9 consoles [solved] Can't connect to PVE9 consoles [solved] [SOLVED] - Use secondary network for PVE commands Created cluster, one node storage gone BUG: proxmox mail gateway FROM = null bypass spam filtering Moving existing PBS from VMWare workstation to PVE cluster Does eBGP SDN fabric support external peering? Bug: PDM 1.1 not recognizing valid license status Proxmox GUI hang - not response PVE crashes unexpectedly Proxmox Backup Server 4.2 released! Advice ceph-osd crashes with kernel 6.17.2-1-pve on Dell system [META] Links on Proxmox Forum Website Hardwarer oder Software RAID Joining a cluster with already created guests VM PDM missing backup jobs from PVE / Log retention Remove VM.Monitor from all users/roles, PVE 9.2 Proxmox Freezing (new instalation) 9.2.2 - Intel 12700T No Web gui and random connection reset by peer [SOLVED] - i40e module for X710 Intel NIC Dutch Proxmox Day 2026 How pools use the space Corosync initiiert Reboot trotz Verfügbarkeit der Systeme Opt-in Linux 7.0 Kernel for Proxmox VE 9 available After PVE 8to9 upgrade, unable to check guest fs freeze status Problem with MegaRAID SAS3508 controller proxmox-kernel-7.0.2-6-pve failing network service Auto sync guest time after rollback of VM snapshot with RAM/state Broadcom BCM57504 (100G) bnxt_en TX timeout and NIC reset on Proxmox 8.1.5 — while BCM57414 (25G) works fine on same host QEMU 11.0 available on pve-test and pve-no-subscription as of now 350 MPM Solventless Lamination Machine for High-Speed Flexible Packaging Making sense of NVMe zfs and SMART errors [SOLVED] - PVE loses network connection after kernel upgrade to proxmox-kernel-7.0.0-3-pve [SOLVED] - Remove or reset cluster configuration. Proxmox 8.4.1 Fresh Install BCM57416 10G Ethernet Adapter Not Recognized PDM 1.1.1 unable to add AD realm with anonymous search [TUTORIAL] - Developer Workstation (Proxmox-VE 9) with cinnamon (LMDE7) SDN zone shows "pending" on peer nodes after node reboot (9.2.x) Cluster not quorate - extending auth key lifetime! Proxmox not rebooting properly (SOLVED) Proxmox 9 Stuck on loading initial ramdisk With new HA-Disarm Feature is there a Documentation for NUT Setup on Clusters? Proxmox 8.3 Installation Issue on ProLiant DL380 Gen9 Cluster networking setup LXC System images unavailable [SOLVED] - Fix: NVIDIA Drivers Failing after upgrade to Proxmox 9.2.2 (Kernel 7.0.2-6-pve) / NovaCore Conflict Install NUT directly on Proxmox VE and control guests from here driver usb for windows 7 System startup error and no network: Failed to start ifupdown2-pre.service - Helper to synchronize boot up for ifupdown. PBS backup space grow up constantly Proxmox Datacenter Manager 1.1 released! IPv4 not available in newly created VM Recommended Setup for Offsite Proxmox Backups? Hetzner Storage Box & Remote PBS Challenges duplicate, please delete this passthrought an USB device "by ID" to CT PDM Installer Freezes at 66% Tried PDM for the first time (version 1.1) - had issues PDM 1.1 automated install Suche Server-Provider für Proxmox connecting sdn to edge firewall SDN, IPAM & DHCP Migrating from read-only file system Ubuntu 26.04 installation fails for unknown reason Status Unbekannt nach Cluster Join Installing Proxmox Backup Server on Mac Mini (Late 2012) kernel 7.0 performance issue with zfs pools PVE becomes unreachable via ethernet but OS is running [SOLVED] - New 9.2 install - can't find 7.0.2-6-pve , not all the time [SOLVED] - Backup and dedupe a VM with LUKS Gibt es mit PVE 2.x ggf. Änderungen bei der RAM-Nutzung, bzw. deren Anzeige bei VMs? I need help for setting up backup solution Way more NAGware, very little functionality, bugs galore Root squashing virtiofsd with --uid-map Intel ixgbe Driver Update Fail Passkey Login (not 2FA) Roblox VM detection - can be overcome? [TUTORIAL] - ZFS-Autosnaptshot inkl. Rollback und Daten direkt recovern (Windows/Linux) How to stop PVE Kernel upgrade [SOLVED] - very long waiting to log in to lxc debian 11 ssh [TUTORIAL] - Configuring Fusion-Io (SanDisk) ioDrive, ioDrive2, ioScale and ioScale2 cards with Proxmox Increase maximum USB devices in vm.conf
[SOLVED] Proxmox VE 9.1 & Broadcom BCM57412 10G SFP Dual Port PCIE adapter
invalid@exam · 2026-06-16 · via Proxmox Support Forum

Flipping a working VMware vSphere vSAN to Proxmox 9.1 and Ceph !

Everything was working on vSphere (ESXi 8 - networking), so no issues with physical switches, vDS, SFP+ etc

but the Broadcom BCM57412 10G SFP Dual Port PCIE adapters are not initialising correctly - firmware - 36.11.73.00

[ 56.425484] bnxt_en 0000:5e:00.0 nic0: NIC Link is Up, 10000 Mbps (NRZ) full duplex, Flow control: none
[ 56.425491] bnxt_en 0000:5e:00.0 nic0: FEC autoneg off encoding: None
[ 56.589621] bnxt_en 0000:5e:00.1 nic1: NIC Link is Up, 10000 Mbps (NRZ) full duplex, Flow control: none
[ 56.589627] bnxt_en 0000:5e:00.1 nic1: FEC autoneg off encoding: None
[ 57.131786] bnxt_en 0000:5e:00.0 nic0: entered allmulticast mode
[ 57.131793] bnxt_en 0000:5e:00.1 nic1: entered allmulticast mode
[ 57.284982] bnxt_en 0000:5e:00.0 nic0: entered promiscuous mode
[ 57.285012] bnxt_en 0000:5e:00.1 nic1: entered promiscuous mode
[ 107.131965] bnxt_en 0000:5e:00.0 nic0: left allmulticast mode
[ 107.131969] bnxt_en 0000:5e:00.1 nic1: left allmulticast mode
[ 107.131977] bnxt_en 0000:5e:00.0 nic0: left promiscuous mode
[ 107.132002] bnxt_en 0000:5e:00.1 nic1: left promiscuous mode
[ 422.776053] bnxt_en 0000:5e:00.0 nic0: Discarding out of seq response: 0x46e for msg {0xd 0x46f}
[ 431.936157] bnxt_en 0000:5e:00.0 nic0: Error (timeout: 5000015) msg {0x27 0x581} len:0
[ 431.936173] bnxt_en 0000:5e:00.0 nic0: failed to update link (rc: fffffff0)
[ 431.936180] bnxt_en 0000:5e:00.0 nic0: failed to update phy settings
[ 437.057744] bnxt_en 0000:5e:00.0 nic0: failed to update phy settings after maximum retries.
[ 440.992789] bnxt_en 0000:5e:00.0 nic0: Error (timeout: 5000015) msg {0x27 0x582} len:0
[ 444.803406] bnxt_en 0000:5e:00.0 nic0: Discarding out of seq response: 0x581 for msg {0x27 0x583}
[ 449.915155] bnxt_en 0000:5e:00.0 nic0: Error (timeout: 5000015) msg {0x27 0x583} len:104
[ 449.915161] bnxt_en 0000:5e:00.0 nic0: failed to update link (rc: fffffff0)
[ 449.915164] bnxt_en 0000:5e:00.0 nic0: update phy settings retry failed
[ 458.797887] bnxt_en 0000:5e:00.0 nic0: Failed setting MC filters rc: -16, turning on ALL_MCAST mode
[ 459.895899] bnxt_en 0000:5e:00.1 nic1: Error (timeout: 5000015) msg {0x27 0x57d} len:0
[ 459.895906] bnxt_en 0000:5e:00.1 nic1: failed to update link (rc: fffffff0)
[ 459.895908] bnxt_en 0000:5e:00.1 nic1: failed to update phy settings
[ 464.828587] bnxt_en 0000:5e:00.0 nic0: Discarding out of seq response: 0x583 for msg {0x93 0x585}
[ 465.026752] bnxt_en 0000:5e:00.1 nic1: failed to update phy settings after maximum retries.
[ 468.866939] bnxt_en 0000:5e:00.1 nic1: Error (timeout: 5000015) msg {0x27 0x57e} len:0
[ 473.743478] bnxt_en 0000:5e:00.0 nic0: Error (timeout: 5000015) msg {0x27 0x586} len:0
[ 473.743484] bnxt_en 0000:5e:00.0 nic0: failed to update link (rc: fffffff0)
[ 473.743488] bnxt_en 0000:5e:00.0 nic0: update phy settings retry failed
[ 482.670548] bnxt_en 0000:5e:00.1 nic1: Failed setting MC filters rc: -16, turning on ALL_MCAST mode
[ 490.860281] bnxt_en 0000:5e:00.1 nic1: Discarding out of seq response: 0x57e for msg {0x93 0x580}
[ 499.795684] bnxt_en 0000:5e:00.1 nic1: Error (timeout: 5000015) msg {0x2a 0x581} len:0
[ 508.725545] bnxt_en 0000:5e:00.1 nic1: Error (timeout: 5000015) msg {0x27 0x582} len:0
[ 508.725559] bnxt_en 0000:5e:00.1 nic1: SP task can't update link (rc: fffffff0)
[ 512.887637] bnxt_en 0000:5e:00.1 nic1: Discarding out of seq response: 0x581 for msg {0x27 0x583}
[ 517.652209] bnxt_en 0000:5e:00.1 nic1: Error (timeout: 5000015) msg {0x27 0x583} len:40
[ 517.652215] bnxt_en 0000:5e:00.1 nic1: failed to update link (rc: fffffff0)
[ 517.652219] bnxt_en 0000:5e:00.1 nic1: update phy settings retry failed

I'm suspecting Firmware, which is 36.11.73.00, we have other new/older servers with Proxmox using same cards on 23.31.18.10, and they seem to be working, so is it firmware, so either we've got to downgrade, or find a new driver!

dmesg | grep -i bnxt
[ 3.723217] bnxt_en 0000:5e:00.0 (unnamed net_device) (uninitialized): Device requests max timeout of 100 seconds, may trigger hung task watchdog (kernel default 120s)
[ 4.051107] bnxt_en 0000:5e:00.0 eth5: Broadcom BCM57412 NetXtreme-E 10Gb Ethernet found at mem b8a10000, node addr b0:26:28:d6:ea:a0
[ 4.051115] bnxt_en 0000:5e:00.0: 63.008 Gb/s available PCIe bandwidth (8.0 GT/s PCIe x8 link)
[ 4.051481] bnxt_en 0000:5e:00.1 (unnamed net_device) (uninitialized): Device requests max timeout of 100 seconds, may trigger hung task watchdog (kernel default 120s)
[ 4.320599] bnxt_en 0000:5e:00.1 eth7: Broadcom BCM57412 NetXtreme-E 10Gb Ethernet found at mem b8a00000, node addr b0:26:28:d6:ea:a1
[ 4.320605] bnxt_en 0000:5e:00.1: 63.008 Gb/s available PCIe bandwidth (8.0 GT/s PCIe x8 link)
[ 4.428338] bnxt_en 0000:5e:00.0 ens2f0np0: renamed from eth5
[ 4.429370] bnxt_en 0000:5e:00.1 ens2f1np1: renamed from eth7
[ 6.772269] bnxt_en 0000:5e:00.1 nic1: renamed from ens2f1np1
[ 6.772937] bnxt_en 0000:5e:00.0 nic0: renamed from ens2f0np0
[ 11.133291] bnxt_en 0000:5e:00.0 nic0: NIC Link is Up, 10000 Mbps (NRZ) full duplex, Flow control: none
[ 11.133298] bnxt_en 0000:5e:00.0 nic0: FEC autoneg off encoding: None
[ 11.289875] bnxt_en 0000:5e:00.1 nic1: NIC Link is Up, 10000 Mbps (NRZ) full duplex, Flow control: none
[ 11.289883] bnxt_en 0000:5e:00.1 nic1: FEC autoneg off encoding: None
[ 11.807301] bnxt_en 0000:5e:00.0 nic0: entered allmulticast mode
[ 11.807304] bnxt_en 0000:5e:00.1 nic1: entered allmulticast mode
[ 11.807401] bnxt_en 0000:5e:00.0 nic0: entered promiscuous mode
[ 11.807429] bnxt_en 0000:5e:00.1 nic1: entered promiscuous mode

rolled back driver to
23.31.18.10
29 Jul 2025

So mlatest firmware from Dell
36.11.56.00
03 Apr 2026

borks Proxmox VE 9.1 !

Hi everyone, I was wondering if problem got solved, if so, can you please show what actions you took.

Thank you
bujar