惯性聚合 高效追踪和阅读你感兴趣的博客、新闻、科技资讯
阅读原文 在惯性聚合中打开

推荐订阅源

cs.AI updates on arXiv.org
cs.AI updates on arXiv.org
P
Palo Alto Networks Blog
S
Securelist
Threat Intelligence Blog | Flashpoint
Threat Intelligence Blog | Flashpoint
NISL@THU
NISL@THU
L
Lohrmann on Cybersecurity
有赞技术团队
有赞技术团队
The GitHub Blog
The GitHub Blog
C
Cisco Blogs
B
Blog
Microsoft Azure Blog
Microsoft Azure Blog
Recent Announcements
Recent Announcements
Simon Willison's Weblog
Simon Willison's Weblog
T
Tenable Blog
Know Your Adversary
Know Your Adversary
Spread Privacy
Spread Privacy
WordPress大学
WordPress大学
月光博客
月光博客
Latest news
Latest news
C
CXSECURITY Database RSS Feed - CXSecurity.com
T
Threat Research - Cisco Blogs
Cisco Talos Blog
Cisco Talos Blog
I
InfoQ
D
Darknet – Hacking Tools, Hacker News & Cyber Security
W
WeLiveSecurity
Hacker News - Newest:
Hacker News - Newest: "LLM"
酷 壳 – CoolShell
酷 壳 – CoolShell
U
Unit 42
C
Cybersecurity and Infrastructure Security Agency CISA
博客园 - 聂微东
人人都是产品经理
人人都是产品经理
Google DeepMind News
Google DeepMind News
Apple Machine Learning Research
Apple Machine Learning Research
Attack and Defense Labs
Attack and Defense Labs
罗磊的独立博客
T
The Exploit Database - CXSecurity.com
I
Intezer
GbyAI
GbyAI
Jina AI
Jina AI
www.infosecurity-magazine.com
www.infosecurity-magazine.com
Blog — PlanetScale
Blog — PlanetScale
博客园 - 司徒正美
Google Online Security Blog
Google Online Security Blog
Engineering at Meta
Engineering at Meta
D
Docker
Recent Commits to openclaw:main
Recent Commits to openclaw:main
小众软件
小众软件
云风的 BLOG
云风的 BLOG
爱范儿
爱范儿
Project Zero
Project Zero

Proxmox Support Forum

[SOLVED] - Github Auth for Mirrors-Kernel Repo? [Automation] Mass migration tool for MS Win11/Server Proxmox GUI hang - not response is it possible to reject or quarantine spam based on conditions I set ? The PVENode task list in PVE9 is partially obscured due to the terminal font being too large. About 100% error reporting due to pveproxy.service hooks Zentraler Speicher No space left on device Combine datastore and direct file archival to tape Kernel panic VFS: Unable to mount root fs on unknown-block (0,0) sobald ein 7.x Kernel verwendet wird. How to migrate disk of a VM from one ZFS to another Windows Server 2025 fails to boot after PVE 9.2 / Linux 7.0 Kernel upgrade Cannot Install Proxmox on T610 Poweredge with H700 PERC card sdn Config. gateway not reachable How to safely change domain/FQDN? Welche Filterquote erreicht ihr? NFS Share status unknown on 2 of 5 nodes Can't connect to PVE9 consoles [solved] Can't connect to PVE9 consoles [solved] [SOLVED] - Use secondary network for PVE commands Created cluster, one node storage gone BUG: proxmox mail gateway FROM = null bypass spam filtering Moving existing PBS from VMWare workstation to PVE cluster Does eBGP SDN fabric support external peering? Bug: PDM 1.1 not recognizing valid license status Proxmox GUI hang - not response PVE crashes unexpectedly Proxmox Backup Server 4.2 released! Advice ceph-osd crashes with kernel 6.17.2-1-pve on Dell system [META] Links on Proxmox Forum Website Hardwarer oder Software RAID Joining a cluster with already created guests VM PDM missing backup jobs from PVE / Log retention Remove VM.Monitor from all users/roles, PVE 9.2 Proxmox Freezing (new instalation) 9.2.2 - Intel 12700T No Web gui and random connection reset by peer [SOLVED] - i40e module for X710 Intel NIC Dutch Proxmox Day 2026 How pools use the space Corosync initiiert Reboot trotz Verfügbarkeit der Systeme Opt-in Linux 7.0 Kernel for Proxmox VE 9 available After PVE 8to9 upgrade, unable to check guest fs freeze status Problem with MegaRAID SAS3508 controller proxmox-kernel-7.0.2-6-pve failing network service Auto sync guest time after rollback of VM snapshot with RAM/state Broadcom BCM57504 (100G) bnxt_en TX timeout and NIC reset on Proxmox 8.1.5 — while BCM57414 (25G) works fine on same host QEMU 11.0 available on pve-test and pve-no-subscription as of now 350 MPM Solventless Lamination Machine for High-Speed Flexible Packaging Making sense of NVMe zfs and SMART errors [SOLVED] - PVE loses network connection after kernel upgrade to proxmox-kernel-7.0.0-3-pve [SOLVED] - Remove or reset cluster configuration. Proxmox 8.4.1 Fresh Install BCM57416 10G Ethernet Adapter Not Recognized PDM 1.1.1 unable to add AD realm with anonymous search [TUTORIAL] - Developer Workstation (Proxmox-VE 9) with cinnamon (LMDE7) SDN zone shows "pending" on peer nodes after node reboot (9.2.x) Cluster not quorate - extending auth key lifetime! Proxmox not rebooting properly (SOLVED) Proxmox 9 Stuck on loading initial ramdisk With new HA-Disarm Feature is there a Documentation for NUT Setup on Clusters? Proxmox 8.3 Installation Issue on ProLiant DL380 Gen9 Cluster networking setup LXC System images unavailable [SOLVED] - Fix: NVIDIA Drivers Failing after upgrade to Proxmox 9.2.2 (Kernel 7.0.2-6-pve) / NovaCore Conflict Install NUT directly on Proxmox VE and control guests from here driver usb for windows 7 System startup error and no network: Failed to start ifupdown2-pre.service - Helper to synchronize boot up for ifupdown. PBS backup space grow up constantly Proxmox Datacenter Manager 1.1 released! IPv4 not available in newly created VM Recommended Setup for Offsite Proxmox Backups? Hetzner Storage Box & Remote PBS Challenges duplicate, please delete this passthrought an USB device "by ID" to CT PDM Installer Freezes at 66% Tried PDM for the first time (version 1.1) - had issues PDM 1.1 automated install Suche Server-Provider für Proxmox connecting sdn to edge firewall SDN, IPAM & DHCP Migrating from read-only file system Ubuntu 26.04 installation fails for unknown reason Status Unbekannt nach Cluster Join Installing Proxmox Backup Server on Mac Mini (Late 2012) kernel 7.0 performance issue with zfs pools PVE becomes unreachable via ethernet but OS is running [SOLVED] - New 9.2 install - can't find 7.0.2-6-pve , not all the time [SOLVED] - Backup and dedupe a VM with LUKS Gibt es mit PVE 2.x ggf. Änderungen bei der RAM-Nutzung, bzw. deren Anzeige bei VMs? I need help for setting up backup solution Way more NAGware, very little functionality, bugs galore Root squashing virtiofsd with --uid-map Intel ixgbe Driver Update Fail Help to fix Proxmox access issues after power cut Passkey Login (not 2FA) Roblox VM detection - can be overcome? [TUTORIAL] - ZFS-Autosnaptshot inkl. Rollback und Daten direkt recovern (Windows/Linux) How to stop PVE Kernel upgrade [SOLVED] - very long waiting to log in to lxc debian 11 ssh [TUTORIAL] - Configuring Fusion-Io (SanDisk) ioDrive, ioDrive2, ioScale and ioScale2 cards with Proxmox Increase maximum USB devices in vm.conf
Kubernetes overlay networking breaks when upgrading from PVE 9.1 to PVE 9.2.3
invalid@exam · 2026-05-31 · via Proxmox Support Forum

I have an odd problem since upgrading my Proxmox cluster from PVE 9.1 to PVE 9.2.3. It consists of three physical proxmox nodes joined together in a cluster. On proxmox I host 3 talos linux control planes and 3 workers. After the update I'm no longer able to reach anything over the pod and service cidr's when the workloads are hosted on a Talos node that's on a different physical proxmox node then the one I'm testing from. Once I migrate the talos nodes together on the same physical proxmox, then traffic on the overlay network starts working again. To rule out kubernetes or the cni's, I've installed different Talos clusters with Cilium and kube-proxy and without kube-proxy and even reinstalled it once with just the standard Flannel cni. To further rule out Talos I've installed a k3s cluster with the built-in flannel cni. Still the same, no traffic over the pod and service cidr's unless the nodes are on the same physical proxmox node.

So today I decided to reinstall proxmox from the 9.1 release iso and reinstalled the Talos nodes, ran my tests and traffic in the overlay network just works. To test even further I upgraded again to 9.2.3 and after that, overlay networking is broken again.

Any help would be greatly appreciated.

Last edited:

I had the same issue after an update from PVE 8.x to 9.x (ended up being 9.2.3). I tried to rollback to 9.1 by forcing the packages but it didn't solve it.

I narrowed down the problem to a network communication problem between kubelet, but I couldn't figure what. I spend a bunch of time disabling the all the firewall checkbox but nothing worked.

After some prompting with Gemini, I got this:

VirtIO Checksum Offloading Bug (The Sneaky Hypervisor Issue)​

This is a notorious issue with Proxmox, virtio network drivers, and Kubernetes VXLANs. Sometimes, the hardware checksum offloading gets confused by the encapsulated VXLAN packets, corrupts the checksum, and the receiving node silently drops the packet because it thinks it's malformed.

The Fix: SSH into your CoreOS nodes and disable TX offloading on your primary network interface (usually eth0 or ens18) to see if it fixes the issue.

Bash:

sudo ethtool -K ens18 tx off

And it worked for me. I've no clue why I happened after the upgrade, everything was fine before and I didn't change anything in the VMs...

To make it permanent (don't forget to adapt your network interface):

Bash:

nmcli connection show
sudo nmcli connection modify "ens18" ethtool.feature-tx off
sudo nmcli connection up "ens18"

@gaetanc

Excellent find! I didn't have such luck when asking copilot and resorted to doing a lot of packet captures. Interestingly the traffic still reaches the virtio nics and the cillium_vxlan interface (where vxlan encapsulation is stripped and the actual UDP packet with pod ip's passes through). I had gotten as far as confirming that the traffic does not reach the pod itself using a netcat listener.

To confirm your ethtool fix works, I had to work around the fact that there's no SSH or shell on Talos Linux:

Bash:

kubectl run tmp-shell --rm -i --tty --image nicolaka/netshoot -n kube-system --overrides='{"spec": {"hostNetwork": true, "nodeName": "talos-w1", "containers": [{"name": "tmp-shell1", "image": "nicolaka/netshoot", "stdin": true, "tty": true, "securityContext": {"privileged": true}}]}}'

This runs a privileged network troubleshooting container and from there I could run the ethtool against the host NIC ens18. After that, it works like you said; my netcat listener received whatever keystrokes I sent from the pod on the other node.

Last edited:

Last edited:

fiona

Proxmox Staff Member

Hi @joelvdvoort and @gaetanc,
did you already try with kernel 7.0.6-2 to see if the backport there fixes the issue?

If it does not, could test with pve-qemu-kvm=10.2.1-2 and pve-qemu-kvm=10.1.2-7. A VM needs to be started fresh after installing to run with the newly installed package version.

What physical NIC do you have?

Last edited:

Hi @fiona,

I've tested it on the latest 7.0.6-2 kernel as well as the older 6.x kernel present using the proxmox boot tool; both did not work.

lshw gives me the following info on the physical nics:

Code:

 *-network
       description: Ethernet interface
       product: RTL8111/8168/8211/8411 PCI Express Gigabit Ethernet Controller
       vendor: Realtek Semiconductor Co., Ltd.
       physical id: 0
       bus info: pci@0000:02:00.0
       logical name: nic0
       version: 15
       serial: [redacted]
       size: 1Gbit/s
       capacity: 1Gbit/s
       width: 64 bits
       clock: 33MHz
       capabilities: pm msi pciexpress msix bus_master cap_list ethernet physical tp mii 10bt 10bt-fd 100bt 100bt-fd 1000bt-fd autonegotiation
       configuration: autonegotiation=on broadcast=yes driver=r8169 driverversion=7.0.6-2-pve duplex=full firmware=rtl8168h-2_0.0.2 02/26/15 latency=0 link=yes multicast=yes port=twisted pair speed=1Gbit/s
       resources: irq:16 ioport:3000(size=256) memory:80804000-80804fff memory:80800000-80803fff

I downgraded the pve-qemu-kvm packages and tested everyting in order. This one pve-qemu-kvm=10.2.1-2 was not working for me and after installing pve-qemu-kvm=10.1.2-7 and rebooting the hosts and vm's, it starting working correctly. With pve-qemu-kvm=10.1.2-7 vxlan overlay networking still works.

Last edited:

fiona

Proxmox Staff Member

Thank you for testing! Between QEMU 10.1 and 10.2 support for negotiating extended VirtIO features was added, so that is likely related to the regression. Unfortunately, we were not yet able to reproduce the issue.

Could you go to the VM monitor qm monitor ID with the numerical ID of the VM and run the following commands

Code:

qm> info virtio
/machine/peripheral/net1/virtio-backend [virtio-net]
/machine/peripheral/virtio0/virtio-backend [virtio-blk]
/machine/peripheral/balloon0/virtio-backend [virtio-balloon]
qm> info virtio-status /machine/peripheral/net1/virtio-backend
/machine/peripheral/net1/virtio-backend:
  device_name:             virtio-net (vhost)
  device_id:               1
...

Once with QEMU 11 or 10.2 and once with QEMU 10.1 so that the outputs can be compared.

fiona

Proxmox Staff Member

If you see the VIRTIO_NET_F_HOST_UDP_TUNNEL_GSO_CSUM with QEMU 11.0, see also the following post:

@shanreich was finally able to reproduce the issue. When the physical NIC does not support the

Code:

tx-udp_tnl-segmentation: off [fixed]
tx-udp_tnl-csum-segmentation: off [fixed]

features, the issue can happen. When the physical NIC does support them, it works. The issue seems to be that the feature negotiation between QEMU/host/guest (AFAICT wrongly) decides to turn on these features for the vNIC even if the underlying physical NIC does not support them. Although they are also turned on for the bridge and tap interfaces. We'll investigate further where exactly the negotiation/setting of...

Last edited:

Thank you for testing! Between QEMU 10.1 and 10.2 support for negotiating extended VirtIO features was added, so that is likely related to the regression. Unfortunately, we were not yet able to reproduce the issue.

Could you go to the VM monitor qm monitor ID with the numerical ID of the VM and run the following commands

Code:

qm> info virtio
/machine/peripheral/net1/virtio-backend [virtio-net]
/machine/peripheral/virtio0/virtio-backend [virtio-blk]
/machine/peripheral/balloon0/virtio-backend [virtio-balloon]
qm> info virtio-status /machine/peripheral/net1/virtio-backend
/machine/peripheral/net1/virtio-backend:
  device_name:             virtio-net (vhost)
  device_id:               1
...

Once with QEMU 11 or 10.2 and once with QEMU 10.1 so that the outputs can be compared.

Please see that attached files for the output. Before I ran the virtio commands I did my end to end tests as well.

  • qemu101.txt

    7.6 KB · Views: 1

  • qemu102.txt

    9.2 KB · Views: 1

  • qemu110.txt

    9.2 KB · Views: 1

If you see the VIRTIO_NET_F_HOST_UDP_TUNNEL_GSO_CSUM with QEMU 11.0, see also the following post:

@shanreich was finally able to reproduce the issue. When the physical NIC does not support the

Code:

tx-udp_tnl-segmentation: off [fixed]
tx-udp_tnl-csum-segmentation: off [fixed]

features, the issue can happen. When the physical NIC does support them, it works. The issue seems to be that the feature negotiation between QEMU/host/guest (AFAICT wrongly) decides to turn on these features for the vNIC even if the underlying physical NIC does not support them. Although they are also turned on for the bridge and tap interfaces. We'll investigate further where exactly the negotiation/setting of...

Please see the attached file for virtio output. I also ran my end to end tests; even with the patch it's still broken.

Additionally see the output below:

Bash:

root@pve1:~# qm showcmd 101 --pretty | grep net
  -netdev 'type=tap,id=net0,ifname=tap101i0,script=/usr/libexec/qemu-server/pve-bridge,downscript=/usr/libexec/qemu-server/pve-bridgedown,vhost=on' \
  -device 'virtio-net-pci,mac=BC:24:11:D1:ED:48,netdev=net0,bus=pci.0,addr=0x12,id=net0,rx_queue_size=1024,tx_queue_size=256,bootindex=102,host_mtu=1500,guest_tunnel_csum=off,host_tunnel_csum=off' \

EDIT: I saw in the other thread that the cause has been found. So the problem gets triggered when the underlying physical nic does not support checksum offloading.

  • qemu110-patched.txt

    8.4 KB · Views: 0

Last edited:

I have the same issue with my Proxmox 9.2.3.

I also run Talos 1.13.3(Issue persists with older version of Talos eg 1.12.8) in Proxmox 9.2.3.
I have 2 identical environments: Proxmox 9.2.3(broken) and Proxmox 9.1.6(working just fine). 3 host nodes, hardware Dell R740/R750/R340.
Both running 6 nodes Talos 1.13.3 with k8s 1.36.1 distributed across nodes: 1 cp per host node and 1 worker per host node.

K8S pods refuse to communicate with each other and corresponding services eg coredns if placed on different nodes in Proxmox 9.2.3. If I migrate all K8S nodes to same Proxmox host - everything starts working.
Environment that is running older version of Proxmox 9.1.6 has no issues. Everything is working. Pods can talk to each other and their services.

Also tried Flannel and Cilium to make sure it is not a CNI configuration issue with the same results - Both CNIs are working on Proxmox 9.1.6 and stopped working in Proxmox 9.2.3

Both K8S clusters are created using same IaC Terraform code. Both Proxmox environments has been configured manually with very basic settings (NTP, Bond). Proxmox 9.2.3 environment known to be working before the upgrade.

Attached requested `qm` debug outputs for both Proxmox 9.2.3(qemu11) and 9.1.6(qemu10)

Please let me know if you need more debug info

  • qemu10.log

    10.7 KB · Views: 4

  • qemu11.log

    12.4 KB · Views: 2

Last edited:

fiona

Proxmox Staff Member

We are still investigating the root cause. Another workaround should be using machine version 10.1 for the affected VMs.

Thanks all for the fix ! ran into this on monday when i tried upgrading our cluster...

i did this (i run only q35 VM, take care to not break i440fx vms !)

Code:

qm list | grep -v VMID | awk '{ print $1; }' | xargs -I '{}' qm set '{}' --machine pc-q35-10.1

and then proceeded to reboot the VMs (qm shutdown xxx; qm start xxx) one by one (same context: talos v1.13.3 nodes losing cross-pve-host EVPN networking, biggest pain was longhorn volumes broken)

Thanks again

Last edited:

I did just notice that running 'ifup eth0' (or whatever your physical interfaces are) fixes this. Is there something to do with vxlans binding somehow to the wrong interface?

Disabling tx offload may just be a red herring. It certainly works, but maybe that is triggering the fix, whatever it may be.

fiona

Proxmox Staff Member

Hi @xrobau,

I did just notice that running 'ifup eth0' (or whatever your physical interfaces are) fixes this. Is there something to do with vxlans binding somehow to the wrong interface?

seems like this does not work on our local reproducer. Are you sure that you have the same issue and it was not just the interface being down for you? Or maybe there was still some effect from an earlier command you tried active? When it is not working (after a fresh boot) what is the output when you run the more verbose command ifup -vd eth0?

Last edited:

I managed to fix my talos cluster by running the following (or adding the args line manually to the config):

qm set 195 --args '-global virtio-net-pci.host_tunnel_csum=off -global virtio-net-pci.csum=off'

I managed to fix my talos cluster by running the following (or adding the args line manually to the config):

qm set 195 --args '-global virtio-net-pci.host_tunnel_csum=off -global virtio-net-pci.csum=off'

This worked for me!
Thanks a lot!

Hi guys,

just a quick note to say thanks to everyone here. We hit the exact same issue on an OKD cluster (cross-host pod/service traffic breaking on PVE 9.2.3 / pve-qemu-kvm 11.0.0-4), and switching the affected VMs to machine type pc-q35-10.1 fixed it for us too.

Thanks a lot!