惯性聚合 高效追踪和阅读你感兴趣的博客、新闻、科技资讯
阅读原文 在惯性聚合中打开

推荐订阅源

The Hacker News
The Hacker News
Threat Intelligence Blog | Flashpoint
Threat Intelligence Blog | Flashpoint
P
Privacy & Cybersecurity Law Blog
C
Cybersecurity and Infrastructure Security Agency CISA
Simon Willison's Weblog
Simon Willison's Weblog
cs.CL updates on arXiv.org
cs.CL updates on arXiv.org
TaoSecurity Blog
TaoSecurity Blog
C
CERT Recently Published Vulnerability Notes
S
Security @ Cisco Blogs
Google DeepMind News
Google DeepMind News
Security Archives - TechRepublic
Security Archives - TechRepublic
T
Tenable Blog
O
OpenAI News
NISL@THU
NISL@THU
AI
AI
T
Threat Research - Cisco Blogs
Know Your Adversary
Know Your Adversary
V
Vulnerabilities – Threatpost
Schneier on Security
Schneier on Security
W
WeLiveSecurity
P
Privacy International News Feed
Cisco Talos Blog
Cisco Talos Blog
S
Secure Thoughts
D
Docker
博客园 - 三生石上(FineUI控件)
T
Troy Hunt's Blog
T
Threatpost
C
Cyber Attacks, Cyber Crime and Cyber Security
Vercel News
Vercel News
H
Hacker News: Front Page
B
Blog
S
SegmentFault 最新的问题
H
Heimdal Security Blog
T
The Blog of Author Tim Ferriss
cs.AI updates on arXiv.org
cs.AI updates on arXiv.org
G
GRAHAM CLULEY
AWS News Blog
AWS News Blog
N
News and Events Feed by Topic
L
LINUX DO - 热门话题
小众软件
小众软件
爱范儿
爱范儿
T
The Exploit Database - CXSecurity.com
Hacker News: Ask HN
Hacker News: Ask HN
Recent Announcements
Recent Announcements
Recent Commits to openclaw:main
Recent Commits to openclaw:main
OSCHINA 社区最新新闻
OSCHINA 社区最新新闻
PCI Perspectives
PCI Perspectives
I
Intezer
云风的 BLOG
云风的 BLOG
P
Proofpoint News Feed

Proxmox Support Forum

[SOLVED] - Github Auth for Mirrors-Kernel Repo? [Automation] Mass migration tool for MS Win11/Server Proxmox GUI hang - not response is it possible to reject or quarantine spam based on conditions I set ? The PVENode task list in PVE9 is partially obscured due to the terminal font being too large. About 100% error reporting due to pveproxy.service hooks Kubernetes overlay networking breaks when upgrading from PVE 9.1 to PVE 9.2.3 Zentraler Speicher No space left on device Combine datastore and direct file archival to tape Kernel panic VFS: Unable to mount root fs on unknown-block (0,0) sobald ein 7.x Kernel verwendet wird. How to migrate disk of a VM from one ZFS to another Windows Server 2025 fails to boot after PVE 9.2 / Linux 7.0 Kernel upgrade Cannot Install Proxmox on T610 Poweredge with H700 PERC card sdn Config. gateway not reachable How to safely change domain/FQDN? Welche Filterquote erreicht ihr? NFS Share status unknown on 2 of 5 nodes Can't connect to PVE9 consoles [solved] Can't connect to PVE9 consoles [solved] [SOLVED] - Use secondary network for PVE commands Created cluster, one node storage gone BUG: proxmox mail gateway FROM = null bypass spam filtering Moving existing PBS from VMWare workstation to PVE cluster Does eBGP SDN fabric support external peering? Bug: PDM 1.1 not recognizing valid license status Proxmox GUI hang - not response PVE crashes unexpectedly Proxmox Backup Server 4.2 released! Advice ceph-osd crashes with kernel 6.17.2-1-pve on Dell system [META] Links on Proxmox Forum Website Hardwarer oder Software RAID Joining a cluster with already created guests VM PDM missing backup jobs from PVE / Log retention Remove VM.Monitor from all users/roles, PVE 9.2 Proxmox Freezing (new instalation) 9.2.2 - Intel 12700T No Web gui and random connection reset by peer [SOLVED] - i40e module for X710 Intel NIC Dutch Proxmox Day 2026 How pools use the space Corosync initiiert Reboot trotz Verfügbarkeit der Systeme Opt-in Linux 7.0 Kernel for Proxmox VE 9 available After PVE 8to9 upgrade, unable to check guest fs freeze status Problem with MegaRAID SAS3508 controller proxmox-kernel-7.0.2-6-pve failing network service Auto sync guest time after rollback of VM snapshot with RAM/state Broadcom BCM57504 (100G) bnxt_en TX timeout and NIC reset on Proxmox 8.1.5 — while BCM57414 (25G) works fine on same host QEMU 11.0 available on pve-test and pve-no-subscription as of now 350 MPM Solventless Lamination Machine for High-Speed Flexible Packaging Making sense of NVMe zfs and SMART errors [SOLVED] - PVE loses network connection after kernel upgrade to proxmox-kernel-7.0.0-3-pve [SOLVED] - Remove or reset cluster configuration. Proxmox 8.4.1 Fresh Install BCM57416 10G Ethernet Adapter Not Recognized PDM 1.1.1 unable to add AD realm with anonymous search [TUTORIAL] - Developer Workstation (Proxmox-VE 9) with cinnamon (LMDE7) SDN zone shows "pending" on peer nodes after node reboot (9.2.x) Cluster not quorate - extending auth key lifetime! Proxmox not rebooting properly (SOLVED) Proxmox 9 Stuck on loading initial ramdisk With new HA-Disarm Feature is there a Documentation for NUT Setup on Clusters? Proxmox 8.3 Installation Issue on ProLiant DL380 Gen9 Cluster networking setup LXC System images unavailable [SOLVED] - Fix: NVIDIA Drivers Failing after upgrade to Proxmox 9.2.2 (Kernel 7.0.2-6-pve) / NovaCore Conflict Install NUT directly on Proxmox VE and control guests from here driver usb for windows 7 System startup error and no network: Failed to start ifupdown2-pre.service - Helper to synchronize boot up for ifupdown. PBS backup space grow up constantly Proxmox Datacenter Manager 1.1 released! IPv4 not available in newly created VM Recommended Setup for Offsite Proxmox Backups? Hetzner Storage Box & Remote PBS Challenges duplicate, please delete this passthrought an USB device "by ID" to CT PDM Installer Freezes at 66% Tried PDM for the first time (version 1.1) - had issues PDM 1.1 automated install Suche Server-Provider für Proxmox connecting sdn to edge firewall SDN, IPAM & DHCP Migrating from read-only file system Ubuntu 26.04 installation fails for unknown reason Status Unbekannt nach Cluster Join Installing Proxmox Backup Server on Mac Mini (Late 2012) kernel 7.0 performance issue with zfs pools PVE becomes unreachable via ethernet but OS is running [SOLVED] - New 9.2 install - can't find 7.0.2-6-pve , not all the time [SOLVED] - Backup and dedupe a VM with LUKS Gibt es mit PVE 2.x ggf. Änderungen bei der RAM-Nutzung, bzw. deren Anzeige bei VMs? I need help for setting up backup solution Way more NAGware, very little functionality, bugs galore Root squashing virtiofsd with --uid-map Intel ixgbe Driver Update Fail Passkey Login (not 2FA) Roblox VM detection - can be overcome? [TUTORIAL] - ZFS-Autosnaptshot inkl. Rollback und Daten direkt recovern (Windows/Linux) How to stop PVE Kernel upgrade [SOLVED] - very long waiting to log in to lxc debian 11 ssh [TUTORIAL] - Configuring Fusion-Io (SanDisk) ioDrive, ioDrive2, ioScale and ioScale2 cards with Proxmox Increase maximum USB devices in vm.conf
ProxMox booting and zfs HD replacement
invalid@exam · 2026-06-16 · via Proxmox Support Forum

Hi all,
I have several problems to replace a HD which is handed over by ProxMox to an OpenMediaVault (VM500) which handles the HDs by zfs.

When ProxMox (8.4.19) boots, on the console I get the message:

Bash:

Port3: ST12000VN0007-2GS116
       S.M.A.R.T Status Bad, Backup and Replace
       Press F1 to continue

(Thats how I first saw the problem)

After pressing F1 boot continues without showing any problems.

On ProxMox: Datacenter ==> svProx1 ==> Disks:
/dev/sdd ... ST12000VN0007-2GS116 ... with Serial ZJV5JAHP <== Shows S.M.A.R.T FAILED!
But no details about the failure are shown and the S.M.A.R.T. values look more or less normal.

Any idea how to find the (detailed) reason of the disk failute ?


FYI: Below svProx1 is the name of the ProxMox server, sv4000 is the name of the OpenMediaVault (VM500) server.

On svProx1, 5* HD's are handed over to OpenMediaVault, which is managing them exclusively by zfs.
ProxMox handed the 5 disks over by

Bash:

qm set 500 -scsil /dev/disk/by-id/ata-ST12000VN0007-2GS116_ZJV205SW
qm set 500 -scsil /dev/disk/by-id/ata-ST12000VN0007-2GS116_ZJV205SW
qm set 500 -scsil /dev/disk/by-id/ata-ST12000VN0007-2GS116_ZJV54B6L
qm set 500 -scsil /dev/disk/by-id/ata-ST12000VN0007-2GS116_ZJV56CPE
qm set 500 -scsil /dev/disk/by-id/ata-ST12000VN0007-2GS116_ZJV5JAHP                                   <== This HD is faulty now
qm set 500 -scsil /dev/disk/by-id/ata-ST12000VN0007-2GS116_ZJV5LWM0

On OpenMediaValut (sv4000) all these HDs were included in one zfs pool 'ZFSRaidZ2'

Code:

sv4000 => ZFS => Pool hinzufügen ZFSRaidZ2 (RAIDZ2 Pool)
Name:        ZFSRaidZ2
Devices:     (all disks)
Mount Point: /ZFSRaidZ2

###--- First idea. I already tried to replace the faulty HD:

Just replaced the faulty HD with a new one, hoping zfs would automatically resilver the disk.
But the OpenMediaVault (VM500) just didn't start anymore, just displaying:

HTML:

Error: start failed: QEMU Exited with code 1
Details: (kvm: -drive file=/dev/disk/by-id/ata-ST12000VN0007-2GS116_ZJV5JAHP,if=none,id=drive-scsi4,format=raw,cache=none,aio=io_uring,detect-zeroes=on: Could not open '/dev/disk/by-id/ata-ST12000VN0007-2GS116_ZJV5JAHP': No such file or directory
TASK ERROR: start failed: QEMU exited with code 1)

I then replaced the new disk again with the faulty one and booted again.
All booted but my first try to replace disk had just failed.


###--- Second idea. My new intention to replace HD:
According to Oracle, the script to replace a disk is to plainly enter:

Bash:

zpool replace ZFSRaidZ2 scsi-0QEMU_QEMU_HARDDISK_drive-scsi4

Since I'm not 100% familiar with zfs, I rather ask for advice before damaging the zfs pool.

I think that would be the correct way, if the zfs pool would be handled directly by ProxMox.

Would that also be the correct way to replace a HD on a ProxMox Server where the HDs are handed over to OpenMediaVault to manage them with zfs ?
That would be the easiest way, if it would work, but I'm afaid I need to involve more manual steps.
Could I damage the zfs pool that way ?
Any suggestions ?


Here, what I did to identify the faulty zfs HD on svProx1 and sv4000:

# Identify HD on svProx1 by Serial number shown on svProx1 UI.

Bash:

root@svProx1:~# lsblk -o NAME,FSTYPE,FSVER,LABEL,FSAVAIL,PARTUUID,PTUUID,SERIAL

NAME      FSTYPE          FSVER    LABEL                     FSAVAIL  PARTUUID                                                         PTUUID                                                              SERIAL

sdd                                                                                                                                                                            9be172dd-2d12-1440-a227-48b5e8af1123 ZJV5JAHP           <== defekt disk,

├─sdd1  zfs_member  5000     ZFSRaidZ2                               5faa4d32-79a5-864b-9ebf-261e0d890e32 9be172dd-2d12-1440-a227-48b5e8af1123                             <== PARTUUID sdd1

└─sdd9                                                                                         6af2a07c-c072-2a48-8a39-203b99406825 9be172dd-2d12-1440-a227-48b5e8af1123                              <== PARTUUID sdd9

# Identify the mount point by PTUUID on sv4000.

Bash:

root@sv4000:~# lsblk -o NAME,FSTYPE,FSVER,LABEL,FSAVAIL,PARTUUID,PTUUID
NAME   FSTYPE             FSVER    LABEL     FSAVAIL PARTUUID                                                        PTUUID
sde                                                                                                                                                           9be172dd-2d12-1440-a227-48b5e8af1123
├─sde1 zfs_member  5000      ZFSRaidZ2              5faa4d32-79a5-864b-9ebf-261e0d890e32 9be172dd-2d12-1440-a227-48b5e8af1123             <== PARTUUID von sde1
└─sde9                                                                         6af2a07c-c072-2a48-8a39-203b99406825 9be172dd-2d12-1440-a227-48b5e8af1123             <== PARTUUID von sde9

On sv4000 the defect HD is handled as sde.

Bash:

# On sv4000 identify the disk-id used by zfs by its mount point
root@sv4000:~# ls -l /dev/disk/by-id | grep sde[1,9]
lrwxrwxrwx 1 root root 10 Jun  2 15:17 scsi-0QEMU_QEMU_HARDDISK_drive-scsi4-part1 -> ../../sde1                            <== Name: scsi-0QEMU_QEMU_HARDDISK_drive-scsi4 von sde1
lrwxrwxrwx 1 root root 10 Jun  2 15:17 scsi-0QEMU_QEMU_HARDDISK_drive-scsi4-part9 -> ../../sde9                            <== Name: scsi-0QEMU_QEMU_HARDDISK_drive-scsi4 von sde9

scsi disk-id is scsi4

Bash:

# Show zfs status on sv4000 (Sadly HDs internal serial numbers are not shown)
ZPOOL_SCRIPTS_AS_ROOT=1 zpool status -c serial
  pool: ZFSRaidZ2
 state: ONLINE
status: Some supported and requested features are not enabled on the pool.
        The pool can still be used, but some features are unavailable.
action: Enable all features using 'zpool upgrade'. Once this is done,
        the pool may no longer be accessible by software that does not support
        the features. See zpool-features(7) for details.
  scan: resilvered 538M in 00:26:06 with 0 errors on Mon May 11 12:40:13 2026
config:

        NAME                                      STATE     READ WRITE CKSUM  serial
        ZFSRaidZ2                                 ONLINE       0     0     0
          raidz2-0                                   ONLINE       0     0     0
            scsi-0QEMU_QEMU_HARDDISK_drive-scsi1  ONLINE       0     0     0       -
            scsi-0QEMU_QEMU_HARDDISK_drive-scsi2  ONLINE       0     0     0       -
            scsi-0QEMU_QEMU_HARDDISK_drive-scsi3  ONLINE       0     0     0       -
            scsi-0QEMU_QEMU_HARDDISK_drive-scsi4  ONLINE       0     0     0       -
            scsi-0QEMU_QEMU_HARDDISK_drive-scsi5  ONLINE       0     0     0       -

errors: No known data errors

Any suggestions ?
Any better ways ?


###--- Third idea to replace faulty HD by manual steps:

# On svProx1 identify the qm handed over scsi disk, by checking the VM500 configuration

Bash:

root@svProx1: more /etc/pve/qemu-server/500.conf
#http://172.16.1.4/#/login
agent: 1
boot: order=scsi0;ide2;net0
cores: 4
cpu: x86-64-v2-AES
ide2: none,media=cdrom
memory: 16384
meta: creation-qemu=8.1.5,ctime=1717161677
name: sv4000
net0: virtio=BC:24:11:30:8E:AB,bridge=vmbr0,firewall=1
net1: virtio=BC:24:11:55:18:BF,bridge=vmbr1,firewall=1
numa: 0
onboot: 1
ostype: l26
scsi0: local-lvm:vm-500-disk-0,iothread=1,size=32G
scsi1: /dev/disk/by-id/ata-ST12000VN0007-2GS116_ZJV54B6L,size=11176G
scsi2: /dev/disk/by-id/ata-ST12000VN0007-2GS116_ZJV205SW,size=11176G
scsi3: /dev/disk/by-id/ata-ST12000VN0007-2GS116_ZJV56CPE,size=11176G
scsi4: /dev/disk/by-id/ata-ST12000VN0007-2GS116_ZJV5JAHP,size=11176G                                       <= Faulty disk identified by serial number
scsi5: /dev/disk/by-id/ata-ST12000VN0007-2GS116_ZJV5LWM0,size=11176G
scsihw: virtio-scsi-single
smbios1: uuid=d242a868-6726-40fb-a9bc-ebd0a8da5dcb
sockets: 1
vmgenid: 86da8a55-11a5-40b2-b93f-4ec31902b01a

# Replace HD by these steps:
# First step: Detach HD from sv4000 zfs

Bash:

root@sv4000: zpool detach ZFSRaidZ2 scsi-0QEMU_QEMU_HARDDISK_drive-scsi4

# Then remove HD form svProx1 handover to sv4000 (eventually with force)

Bash:

root@svProx1: qm unlink 500 --idlist /dev/disk/by-id/ata-ST12000VN0007-2GS116_ZJV5JAHP [--force 1]

# ==> shutdown svProx1
# ==> swap ZJV5JAHP disk against new disk
# ==> boot and identify the new disk by serial number as in steps above
# ==> handover new HD to sv4000

# Again hand the new disk over to sv4000 by qm

Bash:

root@svProx1: qm set 500 -scsil /dev/disk/by-id/ata-... (new HD)

# Attach the new handed over disk to 'ZFSRaidZ2'

Bash:

root@sv4000: zpool atach ZFSRaidZ2 scsi-... new HD
# DO NOT USE add - root@sv4000: zpool add ZFSRaidZ2 scsi-... (new HD) - will create a new pool.

Any step(s) missing ?
Anything else missing ?
Possibility to damage ZFSRaidZ2 pool ?
Any suggestions or better ways ?

Thanks
Rainer