惯性聚合 高效追踪和阅读你感兴趣的博客、新闻、科技资讯
阅读原文 在惯性聚合中打开

推荐订阅源

Spread Privacy
Spread Privacy
人人都是产品经理
人人都是产品经理
U
Unit 42
MyScale Blog
MyScale Blog
T
Tailwind CSS Blog
有赞技术团队
有赞技术团队
Hugging Face - Blog
Hugging Face - Blog
J
Java Code Geeks
F
Full Disclosure
博客园 - 司徒正美
美团技术团队
博客园 - 叶小钗
L
LINUX DO - 热门话题
Blog — PlanetScale
Blog — PlanetScale
Security Latest
Security Latest
博客园 - 聂微东
量子位
Know Your Adversary
Know Your Adversary
H
Hackread – Cybersecurity News, Data Breaches, AI and More
N
Netflix TechBlog - Medium
Threat Intelligence Blog | Flashpoint
Threat Intelligence Blog | Flashpoint
D
DataBreaches.Net
S
Securelist
Recorded Future
Recorded Future
小众软件
小众软件
月光博客
月光博客
W
WeLiveSecurity
宝玉的分享
宝玉的分享
B
Blog
G
GRAHAM CLULEY
P
Privacy International News Feed
让小产品的独立变现更简单 - ezindie.com
让小产品的独立变现更简单 - ezindie.com
C
Cybersecurity and Infrastructure Security Agency CISA
S
SegmentFault 最新的问题
Hacker News: Ask HN
Hacker News: Ask HN
MongoDB | Blog
MongoDB | Blog
奇客Solidot–传递最新科技情报
奇客Solidot–传递最新科技情报
cs.AI updates on arXiv.org
cs.AI updates on arXiv.org
雷峰网
雷峰网
博客园 - Franky
F
Fortinet All Blogs
T
Troy Hunt's Blog
T
The Blog of Author Tim Ferriss
The Register - Security
The Register - Security
阮一峰的网络日志
阮一峰的网络日志
L
LangChain Blog
H
Hacker News: Front Page
N
News and Events Feed by Topic
Google DeepMind News
Google DeepMind News
Scott Helme
Scott Helme

Proxmox Support Forum

[SOLVED] - Github Auth for Mirrors-Kernel Repo? [Automation] Mass migration tool for MS Win11/Server Proxmox GUI hang - not response is it possible to reject or quarantine spam based on conditions I set ? The PVENode task list in PVE9 is partially obscured due to the terminal font being too large. About 100% error reporting due to pveproxy.service hooks Kubernetes overlay networking breaks when upgrading from PVE 9.1 to PVE 9.2.3 Zentraler Speicher No space left on device Combine datastore and direct file archival to tape Kernel panic VFS: Unable to mount root fs on unknown-block (0,0) sobald ein 7.x Kernel verwendet wird. How to migrate disk of a VM from one ZFS to another Windows Server 2025 fails to boot after PVE 9.2 / Linux 7.0 Kernel upgrade Cannot Install Proxmox on T610 Poweredge with H700 PERC card sdn Config. gateway not reachable How to safely change domain/FQDN? Welche Filterquote erreicht ihr? NFS Share status unknown on 2 of 5 nodes Can't connect to PVE9 consoles [solved] Can't connect to PVE9 consoles [solved] [SOLVED] - Use secondary network for PVE commands Created cluster, one node storage gone BUG: proxmox mail gateway FROM = null bypass spam filtering Moving existing PBS from VMWare workstation to PVE cluster Does eBGP SDN fabric support external peering? Bug: PDM 1.1 not recognizing valid license status Proxmox GUI hang - not response PVE crashes unexpectedly Proxmox Backup Server 4.2 released! Advice ceph-osd crashes with kernel 6.17.2-1-pve on Dell system [META] Links on Proxmox Forum Website Hardwarer oder Software RAID Joining a cluster with already created guests VM PDM missing backup jobs from PVE / Log retention Remove VM.Monitor from all users/roles, PVE 9.2 Proxmox Freezing (new instalation) 9.2.2 - Intel 12700T No Web gui and random connection reset by peer [SOLVED] - i40e module for X710 Intel NIC Dutch Proxmox Day 2026 How pools use the space Corosync initiiert Reboot trotz Verfügbarkeit der Systeme Opt-in Linux 7.0 Kernel for Proxmox VE 9 available After PVE 8to9 upgrade, unable to check guest fs freeze status Problem with MegaRAID SAS3508 controller proxmox-kernel-7.0.2-6-pve failing network service Auto sync guest time after rollback of VM snapshot with RAM/state Broadcom BCM57504 (100G) bnxt_en TX timeout and NIC reset on Proxmox 8.1.5 — while BCM57414 (25G) works fine on same host QEMU 11.0 available on pve-test and pve-no-subscription as of now 350 MPM Solventless Lamination Machine for High-Speed Flexible Packaging Making sense of NVMe zfs and SMART errors [SOLVED] - PVE loses network connection after kernel upgrade to proxmox-kernel-7.0.0-3-pve [SOLVED] - Remove or reset cluster configuration. Proxmox 8.4.1 Fresh Install BCM57416 10G Ethernet Adapter Not Recognized PDM 1.1.1 unable to add AD realm with anonymous search [TUTORIAL] - Developer Workstation (Proxmox-VE 9) with cinnamon (LMDE7) SDN zone shows "pending" on peer nodes after node reboot (9.2.x) Cluster not quorate - extending auth key lifetime! Proxmox not rebooting properly (SOLVED) Proxmox 9 Stuck on loading initial ramdisk With new HA-Disarm Feature is there a Documentation for NUT Setup on Clusters? Proxmox 8.3 Installation Issue on ProLiant DL380 Gen9 Cluster networking setup LXC System images unavailable [SOLVED] - Fix: NVIDIA Drivers Failing after upgrade to Proxmox 9.2.2 (Kernel 7.0.2-6-pve) / NovaCore Conflict Install NUT directly on Proxmox VE and control guests from here driver usb for windows 7 System startup error and no network: Failed to start ifupdown2-pre.service - Helper to synchronize boot up for ifupdown. PBS backup space grow up constantly Proxmox Datacenter Manager 1.1 released! IPv4 not available in newly created VM Recommended Setup for Offsite Proxmox Backups? Hetzner Storage Box & Remote PBS Challenges duplicate, please delete this passthrought an USB device "by ID" to CT PDM Installer Freezes at 66% Tried PDM for the first time (version 1.1) - had issues PDM 1.1 automated install Suche Server-Provider für Proxmox connecting sdn to edge firewall SDN, IPAM & DHCP Migrating from read-only file system Ubuntu 26.04 installation fails for unknown reason Status Unbekannt nach Cluster Join Installing Proxmox Backup Server on Mac Mini (Late 2012) kernel 7.0 performance issue with zfs pools PVE becomes unreachable via ethernet but OS is running [SOLVED] - New 9.2 install - can't find 7.0.2-6-pve , not all the time [SOLVED] - Backup and dedupe a VM with LUKS Gibt es mit PVE 2.x ggf. Änderungen bei der RAM-Nutzung, bzw. deren Anzeige bei VMs? I need help for setting up backup solution Way more NAGware, very little functionality, bugs galore Root squashing virtiofsd with --uid-map Intel ixgbe Driver Update Fail Passkey Login (not 2FA) Roblox VM detection - can be overcome? [TUTORIAL] - ZFS-Autosnaptshot inkl. Rollback und Daten direkt recovern (Windows/Linux) How to stop PVE Kernel upgrade [SOLVED] - very long waiting to log in to lxc debian 11 ssh [TUTORIAL] - Configuring Fusion-Io (SanDisk) ioDrive, ioDrive2, ioScale and ioScale2 cards with Proxmox Increase maximum USB devices in vm.conf
Virtueller TS sehr langsam
invalid@exam · 2026-06-18 · via Proxmox Support Forum

Guten Abend zusammen ich habe ein Problem das mein TS mit nur 2 Usern sehr langsam läuft obwohl im Hintergrund performante Hardware steht.

Zu der Hardware:
1x Intel(R) Xeon(R) Gold 6246 CPU @ 3.30GHz (12C/24HT).
256 GB DDR4 ECC 3200 MhZ
2x 1 TB Samsung SSDs (PM893) mit ZFS Raid 1
2x 2 TB Kingston DC600M mit ZFS Raid 1

Auf der Hardware läuft folgendes:

Code:

vTS01:

root@root2235:~# qm config 1001

agent: 1

bios: ovmf

boot: order=scsi0;ide2;ide0;net0

cores: 8

cpu: x86-64-v2-AES

efidisk0: DATA2:vm-1001-disk-0,efitype=4m,ms-cert=2023k,pre-enrolled-keys=1,size=1M

ide0: none,media=cdrom

ide2: none,media=cdrom

machine: pc-q35-10.1

memory: 32768

meta: creation-qemu=10.1.2,ctime=1768302968

name: vTS

net0: virtio=BC:24:11:76:77:29,bridge=vmbr1000

numa: 0

onboot: 1

ostype: win11

scsi0: DATA2:vm-1001-disk-2,iothread=1,size=300G

scsihw: virtio-scsi-single

smbios1: uuid=28561d66-dc75-4835-a204-a3f20b497269

sockets: 1

tags: sandmann;ts

tpmstate0: DATA2:vm-1001-disk-1,size=4M,version=v2.0

vga: std,clipboard=vnc,memory=64

vmgenid: 8d4ac503-6acd-4e98-929f-514de88b3004

Code:

vAPP01:


root@root2235:~# qm config 1003

agent: 1

bios: ovmf

boot: order=scsi0;ide0;net0

cores: 4

cpu: x86-64-v2-AES

efidisk0: DATA2:vm-1003-disk-0,efitype=4m,ms-cert=2023k,pre-enrolled-keys=1,size=1M

ide0: none,media=cdrom

machine: pc-q35-10.1

memory: 32768

meta: creation-qemu=10.1.2,ctime=1768304289

name: vAPP

net0: virtio=BC:24:11:38:C2:47,bridge=vmbr1000

numa: 0

onboot: 1

ostype: win11

scsi0: DATA1:vm-1003-disk-0,iothread=1,size=1100G

scsihw: virtio-scsi-single

smbios1: uuid=c9c61419-f2e3-48c4-bc0c-b475ca9419bf

sockets: 1

tags: app;file;sandmann

tpmstate0: DATA2:vm-1003-disk-1,size=4M,version=v2.0

vga: std,clipboard=vnc

vmgenid: 831d4396-3611-495f-847e-59741af4952f

Code:

vAD:


root@root2235:~# qm config 1004

bios: ovmf

boot: order=scsi0;ide2;ide0;net0

cores: 4

cpu: x86-64-v2-AES

efidisk0: DATA2:vm-1004-disk-0,efitype=4m,ms-cert=2023k,pre-enrolled-keys=1,size=1M

ide0: none,media=cdrom

ide2: none,media=cdrom

machine: pc-q35-10.1

memory: 8192

meta: creation-qemu=10.1.2,ctime=1780059061

name: vAD2

net0: virtio=BC:24:11:01:71:C9,bridge=vmbr1000,firewall=1

numa: 0

onboot: 1

ostype: win11

scsi0: DATA1:vm-1004-disk-0,iothread=1,size=70G

scsihw: virtio-scsi-single

smbios1: uuid=61df06fd-5404-4d11-8bfa-99b5f35d5ab2

sockets: 1

tpmstate0: DATA2:vm-1004-disk-1,size=4M,version=v2.0

vmgenid: 198a1dcb-aa8c-4172-8bd9-7ca9bc019b41

Code:

Firewall PFsense:


root@root2235:~# qm config 2000

agent: 1

boot: order=scsi0;ide2;net0

cores: 4

cpu: x86-64-v2-AES

ide2: none,media=cdrom

memory: 4096

meta: creation-qemu=10.1.2,ctime=1772228358

name: vFW2

net0: virtio=BC:24:11:E3:9D:EB,bridge=vmbr0

net1: virtio=BC:24:11:42:BA:75,bridge=vmbr1000

numa: 0

onboot: 1

ostype: l26

scsi0: DATA2:vm-2000-disk-0,iothread=1,size=32G

scsihw: virtio-scsi-single

smbios1: uuid=c28f8829-4782-4525-b4dd-09b6f6aa8062

sockets: 1

vmgenid: 5bdfa681-6ed4-414e-bfb2-3fc7fb716f11

Die hat eine ANY ANY Regel zum testen drinne.

Der TS hat FSLogicx installiert und nutzt es auch die Laufwerke werden auf den vAPP abgelegt und dort liegen auch andere Daten.

Das Anmelden über den TS dauert in der Regel 2-3 Minuten, und ist danach träge.

Egal ob ich mich Lokal oder über das FSLogix anmelde ist es träge.

Ich würde mich über tipps und anregungen freuen.