惯性聚合 高效追踪和阅读你感兴趣的博客、新闻、科技资讯
阅读原文 在惯性聚合中打开

推荐订阅源

宝玉的分享
宝玉的分享
小众软件
小众软件
J
Java Code Geeks
I
InfoQ
奇客Solidot–传递最新科技情报
奇客Solidot–传递最新科技情报
腾讯CDC
L
LangChain Blog
博客园 - 司徒正美
量子位
Y
Y Combinator Blog
C
Check Point Blog
T
Tailwind CSS Blog
D
DataBreaches.Net
Blog — PlanetScale
Blog — PlanetScale
N
Netflix TechBlog - Medium
钛媒体:引领未来商业与生活新知
钛媒体:引领未来商业与生活新知
F
Fortinet All Blogs
云风的 BLOG
云风的 BLOG
A
About on SuperTechFans
B
Blog RSS Feed
酷 壳 – CoolShell
酷 壳 – CoolShell
大猫的无限游戏
大猫的无限游戏
V
V2EX
阮一峰的网络日志
阮一峰的网络日志

cs.CV updates on arXiv.org

ClawGUI: A Unified Framework for Training, Evaluating, and Deploying GUI Agents On the Robustness of Watermarking for Autoregressive Image Generation Revisiting Compositionality in Dual-Encoder Vision-Language Models: The Role of Inference Anthropogenic Regional Adaptation in Multimodal Vision-Language Model From Redaction to Restoration: Deep Learning for Medical Image Anonymization and Reconstruction The Salami Slicing Threat: Exploiting Cumulative Risks in LLM Systems BoxTuning: Directly Injecting the Object Box for Multimodal Model Fine-Tuning Semantic-Geometric Dual Compression: Training-Free Visual Token Reduction for Ultra-High-Resolution Remote Sensing Understanding Lightweight Low-Light Image Enhancement via Distribution-Normalizing Preprocessing and Depthwise U-Net Back to the Barn with LLAMAs: Evolving Pretrained LLM Backbones in Finetuning Vision Language Models Pseudo-Unification: Entropy Probing Reveals Divergent Information Patterns in Unified Multimodal Models QShield: Securing Neural Networks Against Adversarial Attacks using Quantum Circuits Evaluating the Impact of Medical Image Reconstruction on Downstream AI Fairness and Performance Retinal Cyst Detection from Optical Coherence Tomography Images LoViF 2026 The First Challenge on Weather Removal in Videos STORM: End-to-End Referring Multi-Object Tracking in Videos Data-Efficient Surgical Phase Segmentation in Small-Incision Cataract Surgery: A Controlled Study of Vision Foundation Models Rethinking the Diffusion Model from a Langevin Perspective Zero-shot World Models Are Developmentally Efficient Learners Edu-MMBias: A Three-Tier Multimodal Benchmark for Auditing Social Bias in Vision-Language Models under Educational Contexts VGA-Bench: A Unified Benchmark and Multi-Model Framework for Video Aesthetics and Generation Quality Evaluation Degradation-Consistent Paired Training for Robust AI-Generated Image Detection FREE-Switch: Frequency-based Dynamic LoRA Switch for Style Transfer Demographic and Linguistic Bias Evaluation in Omnimodal Language Models FlowPalm: Optical Flow Driven Non-Rigid Deformation for Geometrically Diverse Palmprint Generation Cross-Cultural Value Awareness in Large Vision-Language Models I Walk the Line: Examining the Role of Gestalt Continuity in Object Binding for Vision Transformers GLEaN: A Text-to-image Bias Detection Approach for Public Comprehension From UAV Imagery to Agronomic Reasoning: A Multimodal LLM Benchmark for Plant Phenotyping Not Your Stereo-Typical Estimator: Combining Vision and Language for Volume Perception
A Systematic Benchmark of Intraoperative Ultrasound-to-MR...
Olga Esteban-Sinovas, Santiago Cepeda, Ignacio Arrese, Rosario S · 2026-05-30 · via cs.CV updates on arXiv.org

Intraoperative ultrasound (ioUS) is a versatile, cost-effective modality in brain tumour surgery, but its interpretation is difficult: acquisition planes are non-standard, artefacts are modality-specific, and its appearance differs markedly from the preoperative MRI on which surgical-planning tools, segmentation models and the surgeon's experience rely. Synthesising MRI-like images from ioUS could let this MRI-based infrastructure be reused intraoperatively without an extra scan. Most prior work evaluates a single architecture in isolation; to our knowledge, no benchmark has spanned architectural paradigms, inference regimes and downstream-task endpoints under a common protocol. We address this gap on the public ReMIND data set (76 patients; 153 paired ioUS/T2w and 104 paired ioUS/FLAIR studies; 60/16 patient-level train/held-out split). Six generators (four GAN baselines: Pix2Pix, SwinPix2Pix, CycleGAN, CUT; the transformer-augmented ResViT; and the few-step diffusion model SynDiff) were each trained under four inference regimes (2D, 2.5D, 2D + 3D-refinement, full-3D) and two targets (T2w only; T2w + FLAIR multi-task), yielding 48 experiments. Image-fidelity metrics (SSIM, PSNR, MAE, LPIPS) were complemented by an nnU-Net v2 downstream segmentation evaluation (tumour and resection cavity) and by subgroup analyses by histological grade and reoperation. No architecture dominated every axis, and, critically, perceptual quality tracked downstream utility most closely (LPIPS, r=-0.66, p<0.001), whereas higher SSIM was associated with worse utility (r=-0.64, p<0.001); SynDiff-2.5D best preserved downstream segmentation (U_Dice=0.55). Perceptual and downstream-task metrics should therefore be reported alongside or in preference to global SSIM, and architecture choice conditioned on surgical phase, patient history and clinical objective.